ATS Control Generator Protection Panels Synchronizing Cabinet for Generator Set

China ATS Control Generator Protection Panels Synchronizing Cabinet for Generator Set, Find details about China Generator Control, Generator Protection Panels from ATS Control Generator Protection Panels Synchronizing Cabinet for Generator Set

Model NO.
BN7521LV
Delivery Time
Within 20 Days
Certification
ISO9001-2000, Ce, CCC
Voltage Level
Low Voltage
Warranty
1 Year or 1000 Working Hours
Quality
Continuous Working
Trademark
BENA
Transport Package
Plywood Case Package
Specification
IEC, GB
Origin
Fuzhou, China
HS Code
8537209000
Model NO.
BN7521LV
Delivery Time
Within 20 Days
Certification
ISO9001-2000, Ce, CCC
Voltage Level
Low Voltage
Warranty
1 Year or 1000 Working Hours
Quality
Continuous Working
Trademark
BENA
Transport Package
Plywood Case Package
Specification
IEC, GB
Origin
Fuzhou, China
HS Code
8537209000

Generator Control & Protection Panels

ATS Control Generator Protection Panels Synchronizing Cabinet for Generator SetATS Control Generator Protection Panels Synchronizing Cabinet for Generator SetATS Control Generator Protection Panels Synchronizing Cabinet for Generator SetATS Control Generator Protection Panels Synchronizing Cabinet for Generator Set
National standard of GB 7251.1-2005, Low-voltage Complete Switch Equipment
National standard of GB 14048-2012, Low-voltage Switch Equipment and Control Equipment
National standard of GB 50169-2006, Code for Construction and Acceptance of Grouding Connection, Electric Equipment Installation Engineering
National standard of GB/T 2820.4-2012, Reciprocating Internal Combustion Engine Driven Alternating Current Generatating Sets-Part 4: Controlgear and Switchgear
ATS Control Generator Protection Panels Synchronizing Cabinet for Generator Set
ATS Control Generator Protection Panels Synchronizing Cabinet for Generator Set
GEK Series of Control Cabinets
Characteristics
     I.  Characteristic appearance design and color matching;
     II. Aviation plugged parts, convenient usage configuration and reliability on the user's site at will;
     III.COMAP controller, selection of closing/manual/automatic/test modes;
     IV.Relay loop shall be fitted with surge protection diode

ATS Control Generator Protection Panels Synchronizing Cabinet for Generator Set
GEB Series of Joint Cabinet
Characteristics
     I.    Optional ABB authorization of MNS-E cabinet type, ABB authorization No. and LOGO;
    II.  Operation lighting of optional automatic LED of humanized front cabinet door and design of document bag of back cabinet door;
     III.  Characteristic appearance design and color matching;
     IV.  Standard copper bar and wire standard;
     V.   Aviation plugged parts, convenient usage configuration and reliability on the user's site at will;
     VI:  Outgoing backup terminal signal can facilitate users to add functional wiring temporarily;
     VII: Lead RS232 to the panel and facilitate data operation and reading;
     VIII:Humanized external power socket for backup.
ATS Control Generator Protection Panels Synchronizing Cabinet for Generator Set
GEF Series of Load Cabinet
Characteristics
     I.    Horizontal air inlet, axial cooling, small noise, small temperature rise;
     II.  Original power consumption parts are made of special type of alloy resistance meterials;
     III.  Different protection level design shall meet different application environment;
     IV.  Friendly human-machine interface shall be matched according to actual application;
     V.   Flexible design and customized production can meet users' non-standard requirements;
     VI:  Load cabinet materials and coating process;
     VII: Cold-rolling steel sheets, industrial level standard spraying; Products have super-strong anti-moisture, heat resistance and corrosion resistance.
ATS Control Generator Protection Panels Synchronizing Cabinet for Generator Set
GEQ Series of Automatic Switchover Cabinet
Characteristics
     I.   Standard copper bar and trace standard;
    II.  Optional configuration of aviation plugged parts; Covenient usage configuration and reliability on the user's site at will;
     III.  Optional ATS controller has automatic/manual mode or selection;
     IV.  Outgoing backup terminal signal can facilitate users' wiring with temporarily added functions;
    V.  IA-NT-PWR controller can be selected to realize short-term parallel operation function of two loops of power;
     VI:  ATS body has short-circuit prtection function of circuit breaker when selecting MCCB or ACB circuit breaker combination;
    VII: It has three-phase city power monitoring function after setting ATS controller.
ATS Control Generator Protection Panels Synchronizing Cabinet for Generator Set
ATS Control Generator Protection Panels Synchronizing Cabinet for Generator Set
ATS Control Generator Protection Panels Synchronizing Cabinet for Generator Set
Outline dimensions of ATS cabinet
                                                            
ModelRated currentATS brand
Aisikai ATSSchneider ATSABB ATS
GEQ - 5050A 500*300*500400*250*500
GEQ - 6363A400*250*500500*300*500400*250*500
GEQ - 8080A400*250*500500*300*500400*250*500
GEQ - 100100A400*250*500500*300*500400*250*500
GEQ - 125125A400*250*500500*300*500400*250*500
GEQ - 160160A400*250*500500*300*500400*250*500
GEQ - 200200A 500*300*500 
GEQ - 250250A500*300*500500*300*500400*250*500
GEQ - 320320A  500*300*500
GEQ - 400400A600*300*600600*400*600500*300*500
GEQ - 500500A600*600*1900  
GEQ - 630630A600*600*1900600*600*1900600*600*1900
GEQ - 800800A1000*600*1900800*600*1900600*600*1900
GEQ - 10001000A1000*600*1900800*600*1900800*600*1900
GEQ - 12501250A1000*600*1900800*600*1900800*600*1900
GEQ - 16001600A1000*600*1900800*600*1900800*600*1900
GEQ - 20002000A1000*800*19001000*800*19001000*600*1900
GEQ - 25002500A1000*800*19001000*800*19001000*600*1900
GEQ - 32003200A1200*800*19001000*800*1900 
GEQ - 40004000A1200*800*19001000*800*1900 
GEQ - 50005000A1200*800*19001000*1000*22 
GEQ - 63006300A1200*800*19001000*1000*22