China Nes-200-5 200watt 5V 12VDC 24V 27V 36V 48V LED Strips Driver, Find details about China LED Strips Driver, Regulated Power Supply from Nes-200-5 200watt 5V 12VDC 24V 27V 36V 48V LED Strips Driver
SPECIFICATION | ||||||||||||||
OUTPUT | ||||||||||||||
Model | NES-200-5 | NES-200-12 | NES-200-15 | NES-200-24 | NES-200-48 | NES-200-50 | ||||||||
DC Voltage | 5V | 12V | 15V | 24V | 48V | 50v | ||||||||
Rated Current | 40A | 17A | 14A | 8.8A | 4.4A | 4A | ||||||||
Current Range | 0~40A | 0~17A | 0~14A | 0~8.8A | 0~4.4A | 0-4A | ||||||||
Rated Power | 200W | 198W | 196W | 194W | 192.5W | 190W | ||||||||
Ripple&Noise | 80mVp-p | 120mVp-p | 120mVp-p | 120mVp-p | 200mVp-p | 200mVp-p | ||||||||
Voltage Adj. Range | 4.75~5.5V | 11.4 ~ 13.5V | 14.25 ~ 16.5V | 22.8 ~ 27.6V | 45.6 ~ 52.8V | 45~55V | ||||||||
Voltage Tolerance | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ||||||||
Line Regulation | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ||||||||
Load Regulation | ±1.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ||||||||
Setup,Rise Time | 800ms, 20ms/230VAC 1200ms, 30ms/115VAC at full load | |||||||||||||
Hold Up Time | 24ms/230VAC 20ms/115VAC at full load | |||||||||||||
INPUT | ||||||||||||||
Voltage Range | 90 ~ 132VAC / 180 ~ 264VAC selected by switch 254 ~ 373VDC | |||||||||||||
Frequency Range | 47 ~ 63Hz | |||||||||||||
Efficiency | 78% | 83% | 83% | 86% | 86% | 86% | ||||||||
AC Current | 3A/115VAC 2A/230VAC | |||||||||||||
Inrush Current | Cold Start 45A/230VAC | |||||||||||||
Leakage Current | <2mA / 240VAC | |||||||||||||
PROTECTION | ||||||||||||||
Over Load | 110 ~ 150% rated output power | |||||||||||||
Protection type: Hiccup mode, recovers automatically after fault condition is removed | ||||||||||||||
Over Voltage | 3.8 ~ 4.65V | 5.75~6.75V | 8.6 ~ 10.1V | 10.4 ~ 12.2V | 13.8~16.2V | 17.25~20.25V | 27.6~32.4V | 55.2~64.8V | 63.2~74.2V | |||||
Protection type: Hiccup mode, recovers automatically after fault condition is removed | ||||||||||||||
ENVIRONMENT | ||||||||||||||
Working Temp. | -20 ~ +60ºC (Refer to output load derating curve) | |||||||||||||
Working Humidity | 20 ~ 90% RH non-condensing | |||||||||||||
StorageTemp., Humidity | -40 ~ +85ºC, 10 ~ 95% RH | |||||||||||||
Temp. Coefficient | ±0.03%/ºC (0 ~ 50ºC) | |||||||||||||
Vibration | 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes | |||||||||||||
SAFETY &EMC | ||||||||||||||
Safety Standards | UL60950-1, CB(IEC60950-1),CCC GB4943 approved | |||||||||||||
Withstand Voltage | I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | |||||||||||||
Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25ºC / 70% RH | |||||||||||||
EMI Conduction & Radiation | Compliance to EN55022 (CISPR22) Class B,GB9254 CLASS B | |||||||||||||
Harmonic Current | Compliance to EN61000-3-2,-3,GB17625.1 | |||||||||||||
EMC Immunity | Compliance to EN61000-4-2, 3, 4, 5, 6, 8,11, ENV50204, EN55024, EN61000-6-1, heavy industry level, criteria A | |||||||||||||
OTHERS | ||||||||||||||
Dimension | 215*115*50mm (L*W*H) | |||||||||||||
Weight | 0.73Kg | |||||||||||||
Packing | 20pcs/carton | |||||||||||||
NOTE | ||||||||||||||
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature. | ||||||||||||||
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. | ||||||||||||||
3. Tolerance: includes set up tolerance, line regulation and load regulation. | ||||||||||||||
4. Line regulation is measured from low line to high line at rated load. | ||||||||||||||
5. Load regulation is measured from 0% to 100% rated load. | ||||||||||||||
6. The power supply is considered a component which will be installed into final equipment. The final equipment must be re-confirmed that it still meetsEMC directives. | ||||||||||||||
7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time. |