110kv Lattice Steel Tower (MGP-110LST01)

China 110kv Lattice Steel Tower (MGP-110LST01), Find details about China 110kv Lattice Steel Tower, 110kv Ohlsteel Tower from 110kv Lattice Steel Tower (MGP-110LST01)

Model NO.
MGP-110LST01
Lattice Type with Angle or Tubular Tower
We Design by Pls Software for Client
Accessories 1
Power Fitting
Accessories 2
Insulator
Accessories 3
Conductor and Cable
Accessories 4
Earth Wire and Opgw
Accessories 5
Aviation Light
Accessories 6
Tower Foundation and Anchor Bolt
Accessories 7
Tower Earthing Kits and Template
Accessories 8
Anti-Climbing Devices
Accessories 9
Anti-Bird Devices
Other Services 1
Installation Guide
Other Services 2
Engineering Consultant
Other Services 3
Project Budget
Trademark
MEGATRO
Transport Package
Export Stnadard Package
Specification
AS PER CLIENT
Origin
Shandong, China
HS Code
73082000
Model NO.
MGP-110LST01
Lattice Type with Angle or Tubular Tower
We Design by Pls Software for Client
Accessories 1
Power Fitting
Accessories 2
Insulator
Accessories 3
Conductor and Cable
Accessories 4
Earth Wire and Opgw
Accessories 5
Aviation Light
Accessories 6
Tower Foundation and Anchor Bolt
Accessories 7
Tower Earthing Kits and Template
Accessories 8
Anti-Climbing Devices
Accessories 9
Anti-Bird Devices
Other Services 1
Installation Guide
Other Services 2
Engineering Consultant
Other Services 3
Project Budget
Trademark
MEGATRO
Transport Package
Export Stnadard Package
Specification
AS PER CLIENT
Origin
Shandong, China
HS Code
73082000
110kv Lattice Steel Tower (MGP-110LST01)110KV lattice steel tower
Steel lattice structures of rolled equal angles, either fully bolted together or partially so in combination with welded sections. The surface of these items is protected by hot galvanisation or a suitable alternative coating. This series is divided into subgroups of specific applications, i.e. support, tension, anchor, branch or underpass towers.
In material, it is divided into three types, completely lattice angular tower, completely lattice tubular tower or combined tower by angle and tube, this tower often stub legs by tube and bracing, gusset and web part by angle steel. This type tower was widely use in Asian countries, or even some European or other regions. We are professional manufacturer for this type of steel tower. 'MEGATRO had professional QA &QC team to control quality and execute strict QC & QC plan as per client requirements. MEGATRO is one of the few manufactures who assemble a face of 110KV overhead transmission line steel tower. This attention to quality may not be the cheapest process but it does insure every tower meets our high standards of quality. And it helps to reduce on-site construction cost due to mismatched assemblies.

After fabrication all 110KV overhead transmission line steel tower are delivered to the galvanizing facility to be Hot DIP Galvanized. Towers are processed through the facility by Caustic Cleaning, Pickling, and then Fluxing. These strict procedures insure years of maintenance free towers. Even we take secondary finish for client again, which as duplex surface treatment. The duplex coating applied in our own paint shop.
Duplex surface treatment involves sand-blasting to remove 5-10 microns of the 70-150 micron thick hot dip galvanization coating. This removes any contaminants and roughens the surface. Almost immediately afterwards, in a controlled atmospheric environment, water-based painting, specially developed and manufactured for this purpose, is applied to the tower (structures) to a thickness of 80-120 microns.

MEGATRO's 110KV lattice steel tower systems can accommodate a variety of cross-arm. MEGATRO also offers a wide variety of accessories and mounts.
In Design, our main design engineer from USA, can use PLS software to design every type steel tower based on structural calculations and geometrical frame drawings.
Standard: Chinese or other standard):
1. GB/T2694-2003 Transmission line tower - - Technical requirements for manufacturing
2. JGJ81-2002: Technical specification for welding for steel structure of building
3. GB9787-88: Measuring and allowable tolerance for hot-rolled equal angle
4. GB709-88: Measuring and allowable tolerance for hot-rolled plate and strip
5. GB/T699-1999: Quality Carbon Structural Steel
6. GB/T1591-1994: Low alloy high strength structural Steel
7. GB700-88: Carbon Structural Steel
8. GB222-84: Method of sampling steel for determination of chemical composition and permissible variations
9. GB/T228-2002: Method for Tensile testing of metals
10 GB/T232-1999: Method for Bending test of metals
11 GB/T5117-1995: Carbon Welding Rod
12 GB/T5118-1995: Low Alloy Welding Rod
13 GB/T8110-1995: Welding wires for gas shielding arc welding of carbon and low alloy steels
14 GB/T10045-2001: Carbon steel flux cored electrodes for arc welding
15 JB/T7949-1999: Weld outer dimensions for steel construction
16 GB50205-2001: Test Standard for Acceptance of Steel Structure
17 GB/T470-1997: Zinc Ingot
18 GB3098.1-2000: Mechanical properties of fasteners-Part 1: Bolts, screws and studs
19 GB3098.2-2000: Mechanical properties of fasteners-Part2: Nuts, and thread
20 GB3098.3-2000: Mechanical properties of fasteners-Part3: Fastening screw
21 GB/T5780-2000: Helical Bolts Grade C
22 GB/T41-2000: Helical Nuts Grade C
23 GB/T90-2002: Flat Washer Grade C
24 GB/T13912-2002: Metal Coating, Technical Requirement