AC DC Current Sensor K3 50A 100A 200A 300A 400A 500A Hall Effect Sensors Electrical Current Transducer

China AC DC Current Sensor K3 50A 100A 200A 300A 400A 500A Hall Effect Sensors Electrical Current Transducer, Find details about China Current Sensor, Open Loop Hall Current Sensor from AC DC Current Sensor K3 50A 100A 200A 300A 400A 500A Hall Effect Sensors Electrical Current Transducer

Model NO.
K3
IP Rating
IP65
Certification
ISO
Customized
Customized
Rated Output
@IP=±ipn
Usage
Hall Sensor
Zero Voltage
Hall Sensor
Trademark
HEYI
Transport Package
Green Plastic Film
Specification
CE, ISO, Rohs
Origin
Liushi, Yueqing, Zhejiang Province, China
HS Code
8542390000
Model NO.
K3
IP Rating
IP65
Certification
ISO
Customized
Customized
Rated Output
@IP=±ipn
Usage
Hall Sensor
Zero Voltage
Hall Sensor
Trademark
HEYI
Transport Package
Green Plastic Film
Specification
CE, ISO, Rohs
Origin
Liushi, Yueqing, Zhejiang Province, China
HS Code
8542390000

K3 series hall effect current sensor is an open loop device based on the measuring principle of the hall effect, with a galvanic isolation between primary and secondary circuit. It provides accurate electronic measurement of DC, AC or pulsed currents.

Electrical data (Ta=25ºC±5ºC,RL=2KΩ,CL=10000PF)
 
TypeK3-50AK3-100AK3-200AK3-300AK3-400AK3-500AK3-600AUnit
Rated current(Ipn)±50±100±200±300±400±500±600A
Measure range(Ip)±100±200±400±600±800±900±900A
Rated output@Ip=±Ipn ±4±1%V
Supply voltage±12,±15V
Power Consumption<25mA
Offset voltage@Ip=0 ±25mV
Magnetic offset@Ip=±Ipn-0 ±30mV
Offset drift@ -40~+85ºC ≤±1mV/ºC
Output drift@ -40~+85ºC ≤±1mV/ºC
Linearity@Ip=0-±Ipn ≤1%FS
Response time@50A/μS, 10%-90% ≤5μs
Galvanic isolation@ 50HZ,AC,1min 2.5KV
Wire length650~750mm
 
Applications
·Variable speed drives
·Welding machine
·Battery supplied applications
·Uninterruptible Power Supplies (UPS)
·Electrochemical
AC DC Current Sensor K3 50A 100A 200A 300A 400A 500A Hall Effect Sensors Electrical Current Transducer

Remarks:
1. All dimensions are in mm.
2. General tolerance ±1mm.
3. Elucidation: 1:+15V 2:-15V 3:V0UT 4:0V
 
Directions for use
1. When the current will be measured goes through a sensor, the voltage will be measured at the output end.(Note: The false wiring may result in the damage of the sensor)
2. Custom design in the different rated input current and the output voltage are available.
Standards
·UL94-V0.
·EN60947-1:2004
·IEC60950-1:2001
·EN50178:1998
·SJ 20790-2000
General date
 
 ValueUnit
Operating temperature(TA)-40 to +85ºC
Storage temperature(TS)-40 to +125ºC
Mass(approx) (M)K3:55,K3R:80g