China 15kVA 20kVA 30kVA 45kVA 60kVA Electric Power Inverter, Find details about China 60kVA Electric Power Inverter, 45kVA Electric Power Inverter from 15kVA 20kVA 30kVA 45kVA 60kVA Electric Power Inverter
Model | ACME220 -1010 | ACME220 -1030 | ACME220 -1050 | ACME220 -1075 | ACME220 -1100 | ||||
DC input | Rated voltage (VDC) | 220 | |||||||
Input rating current (A) | 5.0 | 15.2 | 25 | 38 | 50 | ||||
Input DC voltage range (VDC) | 180-300 | ||||||||
Bypass input | Voltage(VAC) | 220v±15% | |||||||
Rated current(A) | 4.5 | 13.6 | 22.7 | 34.1 | 45.5 | ||||
Switching time | Bypass-inversion(MS) | ≤4 | |||||||
AC output | Rating capacity (KVA) | 1 | 3 | 5 | 7.5 | 10 | |||
Output rating power (KW) | 0.8 | 2.4 | 4.0 | 6.0 | 8.0 | ||||
Output rating voltage and frequency | 220VAC, 50HZ | ||||||||
Output rating current (A) | 4.5 | 13.6 | 22.7 | 34.1 | 45.5 | ||||
Output voltage precision(V) | 220±3% | ||||||||
Output frequency precision(Hz) | 50±0.05 | ||||||||
THD | ≤3% | ||||||||
Dynamic response (load 0←→100%) | 5% | ||||||||
Power factor(PF) | 0.8 | ||||||||
Load ability | 150%,10scends | ||||||||
Crest factor (CF) | 3:1 | ||||||||
Inversion efficiency | 92% | ||||||||
Working environment | Insulation strength(input and output) | 1500VAC,1minute | |||||||
Noise(1meter) | ≤50dB | ||||||||
temperature | -10ºC~+50ºC | ||||||||
Humidity | 0~90%,no condensing | ||||||||
Altitude(m) | ≤2000 | ||||||||
Protection function | Input reversing protection input low-voltage protection output over-load protection output short-circuit protection, over-heat protection | ||||||||
Other | Industrial isolation transformer, pure sine wave output, strong load capacity. |
Model | ACME220 -1150 | ACME220 -1200 | ACME220 1300 | ACME220 -1450 | ACME220 -1600 | |
DC input | input rating voltage (VDC) | 220 | ||||
Input rating current (A) | 75 | 99 | 148 | 225 | 250 | |
Input DC voltage allowing range (VDC) | 180~300 | |||||
AC bypass input | Allowing input voltage range(VAC) | 220±15% | ||||
Input rating current (A) | 67.5 | 91 | 136 | 202 | 273 | |
Bypass switch time (ms) | ≤4 | |||||
AC output | Rating capacity (KVA) | 15 | 20 | 30 | 45 | 60 |
Output rating power (KW) | 12 | 16 | 24 | 36 | 48 | |
Output rating voltage and frequency | 220VAC, 50HZ | |||||
Output rating current (A) | 67.5 | 91 | 136 | 202 | 273 | |
Output voltage precision(V) | 220±3% | |||||
Output frequency precision(Hz) | 50±0.05 | |||||
Waveform deviation factor (THD)(liner load) | ≤3% | |||||
Dynamic response (load 0←→100%) | 5% | |||||
Power factor(PF) | 0.8 | |||||
Load ability | 150%,10scends | |||||
Crest factor (CF) | 3:1 | |||||
Inverted efficiency | 92% | |||||
Working environment | Insulation strength(input and output) | 1500VAC,1minute | ||||
Noise(1meter) | ≤50dB | |||||
using condition temperature | -10ºC~+50ºC | |||||
temperature | 0~90%,no condensing | |||||
Using altitude(m) | ≤2000 | |||||
Protection function | Input reversing protection, input low-voltage protection, output over-load protection, output short-circuit protection, over-heat protection |