Model | ACME220 -1010 | ACME220 -1030 | ACME220 -1050 | ACME220 -1075 | ACME220 -1100 | ||||
DC input | Rated voltage (VDC) | 220 | |||||||
Input rating current (A) | 5.0 | 15.2 | 25 | 38 | 50 | ||||
Input DC voltage range (VDC) | 180-300 | ||||||||
Bypass input | Voltage(VAC) | 220v±15% | |||||||
Rated current(A) | 4.5 | 13.6 | 22.7 | 34.1 | 45.5 | ||||
Switching time | Bypass-inversion(MS) | ≤4 | |||||||
AC output | Rating capacity (KVA) | 1 | 3 | 5 | 7.5 | 10 | |||
Output rating power (KW) | 0.8 | 2.4 | 4.0 | 6.0 | 8.0 | ||||
Output rating voltage and frequency | 220VAC, 50HZ | ||||||||
Output rating current (A) | 4.5 | 13.6 | 22.7 | 34.1 | 45.5 | ||||
Output voltage precision(V) | 220±3% | ||||||||
Output frequency precision(Hz) | 50±0.05 | ||||||||
THD | ≤3% | ||||||||
Dynamic response (load 0←→100%) | 5% | ||||||||
Power factor(PF) | 0.8 | ||||||||
Load ability | 150%,10scends | ||||||||
Crest factor (CF) | 3:1 | ||||||||
Inversion efficiency | 92% | ||||||||
Working environment | Insulation strength(input and output) | 1500VAC,1minute | |||||||
Noise(1meter) | ≤50dB | ||||||||
temperature | -10ºC~+50ºC | ||||||||
Humidity | 0~90%,no condensing | ||||||||
Altitude(m) | ≤2000 | ||||||||
Protection function | Input reversing protection input low-voltage protection output over-load protection output short-circuit protection, over-heat protection | ||||||||
Other | Industrial isolation transformer, pure sine wave output, strong load capacity. |
Model | ACME220 -1150 | ACME220 -1200 | ACME220 1300 | ACME220 -1450 | ACME220 -1600 | |
DC input | input rating voltage (VDC) | 220 | ||||
Input rating current (A) | 75 | 99 | 148 | 225 | 250 | |
Input DC voltage allowing range (VDC) | 180~300 | |||||
AC bypass input | Allowing input voltage range(VAC) | 220±15% | ||||
Input rating current (A) | 67.5 | 91 | 136 | 202 | 273 | |
Bypass switch time (ms) | ≤4 | |||||
AC output | Rating capacity (KVA) | 15 | 20 | 30 | 45 | 60 |
Output rating power (KW) | 12 | 16 | 24 | 36 | 48 | |
Output rating voltage and frequency | 220VAC, 50HZ | |||||
Output rating current (A) | 67.5 | 91 | 136 | 202 | 273 | |
Output voltage precision(V) | 220±3% | |||||
Output frequency precision(Hz) | 50±0.05 | |||||
Waveform deviation factor (THD)(liner load) | ≤3% | |||||
Dynamic response (load 0←→100%) | 5% | |||||
Power factor(PF) | 0.8 | |||||
Load ability | 150%,10scends | |||||
Crest factor (CF) | 3:1 | |||||
Inverted efficiency | 92% | |||||
Working environment | Insulation strength(input and output) | 1500VAC,1minute | ||||
Noise(1meter) | ≤50dB | |||||
using condition temperature | -10ºC~+50ºC | |||||
temperature | 0~90%,no condensing | |||||
Using altitude(m) | ≤2000 | |||||
Protection function | Input reversing protection, input low-voltage protection, output over-load protection, output short-circuit protection, over-heat protection |