China SMPS 12V 24V 15W Single Output 120VAC 230VAC to 12VDC 1.25A 24VDC 0.62A Industrial DIN Rail DC Power Supply, Find details about China DC Power Supply, DIN Power Supply from SMPS 12V 24V 15W Single Output 120VAC 230VAC to 12VDC 1.25A 24VDC 0.62A Industrial DIN Rail DC Power Supply
Features:
Universal AC input/ full rangeSPECIFICATIONS | ||||
OUTPUT | ||||
Model | DR-15-5 | DR15-12 | DR-15-15 | DR-15-24 |
DC Voltage | 5V | 12V | 15V | 24V |
Rated Current | 2.4A | 1.25A | 1A | 0.63A |
Current Range | 0-2.4A | 0-1.25A | 0-1A | 0-0.63A |
Rated Power | 12W | 15W | 15W | 15.2W |
Ripple & Noise | 80mVp-p | 120mVp-p | 120mVp-p | 150mVp-p |
Voltage Adj. Range | 4.75-5.5V | 10.8-13.2V | 13.5-16.5V | 21.6-26.4V |
Voltage Tolerance | ±2% | ±1% | ±1% | ±1% |
Line regulation | ±1% | ±1% | ±1% | ±1% |
Load regulation | ±1% | ±1% | ±1% | ±1% |
Setup, Rise, Hold Up Time | 1000ms, 50ms/230VAC 1000ms, 50ms/115VAC at full load 70ms/230VAC 16ms/115VAC at full load | |||
INPUT | ||||
Voltage Range | 85 ~ 264VAC 120 ~ 370VDC | |||
AC Current | 0.88A/115VAC 0.48A/230VAC | |||
Efficiency | 77% | 84% | 83.50% | 85% |
Inrush Current | COLD START 35A/115VAC 65A/230VAC | |||
PROTECTION | ||||
Over Load | 105%~160% rated output power | |||
Protection type: Constant current limiting, recovers automatically after fault condition is removed | ||||
Over Voltage | 5.75-6.75V | 13.8-16.2V | 17.25-20.25V | 27.6-32.4V |
Protection type: Shut off o/p voltage, clamping by zener diode | ||||
ENVIRONMENT | ||||
Working Temp., Humidity | -20°~+60°; 20%~90% RH non-condensing | |||
Storage Temp., Humidity | -40°~+85°; 10%~95%RH | |||
Temp. Coefficient | ±0.03%/°(0~50°) | |||
Vibration | 10~500Hz, 2G 10min./1cycle, period for 60min, each along X, Y, Z axes, Mounting: Compliance to IE60068-2-6 | |||
SAFETY | ||||
Withstand Voltage | I/P-O/P: 3KVAC | |||
Isolation Resistance | I/P-O/P: 100M Ohms / 500VDC/ 25°/ 70%RH | |||
STANDARD | ||||
Safety Standard | Design refer to UL60950-1,TUV EN60950-1,EN50178 | |||
EMC Standard | Design refer to EN55011,EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11,EN55024,EN61000-6-2,EN61204-3, heavy industry level, criteria A | |||
OTHERS | ||||
Dimension | 25*93*56mm(W*H*D) | |||
Weight | 0.1Kg | |||
Packing | 140pcs/15KG/0.92CUFT | |||
NOTE | ||||
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25° of ambient temperature. | ||||
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μ & 47μ parallel capacitor. | ||||
3. Tolerance: includes set up tolerance, line regulation and load regulation. | ||||
4. The power supply is considered a component which will be installed into final equipment. The final equipment must be re-confirmed that it still meets EMC directives. |