China Three Phase 60ka-250ka Voltage and Frequency Stabilizer, Find details about China 250kVA Frequency Stabilizer, 200kVA Frequency Stabilizer from Three Phase 60ka-250ka Voltage and Frequency Stabilizer
Model | ACME 50-33060 | ACME 50-33100 | ACME 50-33150 | ACME 50-33200 | ACME 50-33300 | ACME 50-33450 | |
Capacity | 6KVA | 10KVA | 15KVA | 20KVA | 30KVA | 45KVA | |
Circuit model | IGBT/SPWM pulse width adjustment mode | ||||||
Input | phase | three phase | |||||
voltage | 265V-495V | ||||||
frequency | 30Hz-70Hz | ||||||
Output | Phase | Three(three phase four wire or three phase three wire) | |||||
waveform | SINE WAVE | ||||||
voltage | 380V | ||||||
power stability | ≤1% | ||||||
load stability | ≤1% | ||||||
frequency | 50Hz/60Hz/±10% | ||||||
frequency stability | ≤0.01% | ||||||
Wave distortion | THD≤2% | ||||||
Efficiency | ≥94%(100%Load) | ||||||
Reaction time | ≤2mS | ||||||
Display | High precision LED display, Voltage current frequency power and PF | ||||||
Cooling method | Compulsive fan cooling | ||||||
Protection function | over voltage, over current, over temperature, over load, short circuit, and automatic alarm | ||||||
Insulation reactance | 500Vdc 10MΩ | ||||||
Pressure endurance | 1800Vac/5mA/1minute | ||||||
Environment | Working temperature | -15ºC-45ºC | |||||
Relative humidity | 0-90%(No condensing) | ||||||
Altitude | 1500meters |
Model | ACME 50-33600 | ACME 50-33750 | ACME 50-331000 | ACME 50-331500 | ACME 50-332000 | ACME 50-332500 | ||
Capacity | 60KVA | 75KVA | 100KVA | 150KVA | 200KVA | 250KVA | ||
Circuit mode | IGBT/SPWM pulse width adjustment mode | |||||||
Input | phase | three phase | ||||||
voltage | 265V-495V | |||||||
frequency | 30Hz-70Hz | |||||||
Output | Phase | three | ||||||
Waveform | SINE WAVE | |||||||
voltage | 380V | |||||||
power stability | ≤1% | |||||||
load stability | ≤1% | |||||||
frequency | 50Hz/60Hz/±10% | |||||||
frequency stability | ≤0.01% | |||||||
Wave distortion | THD≤2% | |||||||
Efficiency | ≥94%(100%Load) | |||||||
Reaction time | ≤2mS | |||||||
Ammeter display | High precision LED display , Voltage current frequency power and PF | |||||||
Cooling method | Compulsive fan cooling | |||||||
Protection function | over voltage, over current, over temperature, over load, short circuit, and automatic alarm | |||||||
Insulation reactance | 500Vdc 10MΩ | |||||||
Pressure endurance | 1800Vac/5mA/1minute | |||||||
Environment | Working temperature | -15ºC-45ºC | ||||||
Relative humidity | 0-90%(No condensing) | |||||||
Altitude | 1500meters |
Model | ACME 50-333000 | ACME 50-334500 | ACME 50-335000 | ACME 50-336000 | ACME 50-338000 | ||
Capacity | 300KVA | 450KVA | 500KVA | 600KVA | 800KVA | ||
Circuit model | IGBT/SPWM pulse width adjustment mode | ||||||
Input | phase | three phase | |||||
voltage | 265V-495V | ||||||
frequency | 30HZ-70Hz | ||||||
Output | Phase | three | |||||
waveform | SINE WAVE | ||||||
voltage | 380V | ||||||
power stability | ≤1% | ||||||
load stability | ≤1% | ||||||
frequency | 50Hz/60Hz | ||||||
frequency stability | ≤0.01% | ||||||
Wave distortion | THD≤2% | ||||||
Efficiency | ≥94%(100%Load) | ||||||
Reaction time | ≤2mS | ||||||
Display | High precision LED display, Voltage current frequency power and PF | ||||||
Cooling method | Compulsive fan cooling | ||||||
Protection function | over voltage, over current, over temperature, over load, short circuit, and automatic alarm | ||||||
Environment | Insulation reactance | 500Vdc 10MΩ | |||||
Pressure endurance | 1800Vac/5mA/1minute | ||||||
Working temperature | -15ºC-45ºC | ||||||
Relative humidity | 0-90%(No condensing) | ||||||
Altitude | 1500meters |