ISO 9705 Room Corner Burning Testing Equipment for Building Materials

China ISO 9705 Room Corner Burning Testing Equipment for Building Materials, Find details about China Room Corner Tester, ISO 9705 Room Corner Burning Testing Equipment from ISO 9705 Room Corner Burning Testing Equipment for Building Materials

Model NO.
GD 9705
Control Way
Computer
Utilities
Propane Gas Valve System, Ignition System
Exhaust
3.5m3/S
Size
3, 600 (W) *2, 400 (D) * 2, 400 (H)
Consumption and Yield Measurement
O2, Co and CO2
Manual
Provide
Shipping Port
Shanghai
Delivery Time
to Be Negotiated
Oversea Training
Supply
Trademark
GOLD
Transport Package
Plywood
Origin
Chongqing China(Mainland)
HS Code
9031809090
Model NO.
GD 9705
Control Way
Computer
Utilities
Propane Gas Valve System, Ignition System
Exhaust
3.5m3/S
Size
3, 600 (W) *2, 400 (D) * 2, 400 (H)
Consumption and Yield Measurement
O2, Co and CO2
Manual
Provide
Shipping Port
Shanghai
Delivery Time
to Be Negotiated
Oversea Training
Supply
Trademark
GOLD
Transport Package
Plywood
Origin
Chongqing China(Mainland)
HS Code
9031809090
ISO 9705 Room Corner Burning Testing Equipment For Building Materials

Image:
ISO 9705 Room Corner Burning Testing Equipment for Building Materials

Introduction:

(RCT), as ISO's evaluation of the fire-resistance performance of building materials, measures heat release rate (H.R.R), smoke generation rage, oxygen consumption, CO, CO2 production and so on. 
As the basis of ISO 9705(ISO 9705 Room Corner Burning Testing Equipment For Building Materials), RCT is the test that reproduces local fire conditions by flame combustion in the small room of building structure and measures fire movement and combustion diffusion in the building structure. 


International standards:

ISO 9705: Fire tests - Full-scale room test for surface products. 
• ISO 13784-1: Reaction to fire tests for sandwich panel building systems. 
• ASTM E 1537:  Standard Test Method for Fire Testing of Upholstered Furniture. 
• ASTM E 603:  Standard Guide for Room Fire Experiments. 
GB/T 25207-2010: Fire test methods for soil room fire test for surface products
NFPA 265: Standard Methods of Fire Tests for Evaluating Room Fire Growth Contribution of Textile Coverings on Full Height Panels and Walls. 
NFPA 286: Standard Methods of Fire Tests for Evaluating Contribution of Wall and Ceiling Interior Finish to Room Fire Growth.


Features:

-Measuring Section. 
- Bi-Directional Probes & DPT (Differential Pressure Transducer) for measuring flow rate in the duct. 
- Thermocouples for measuring temperature in the duct.
- Sampling Port & Analyzer (O2, CO2, CO) for collecting and analyzing generated gases. 
- The laser used to measure the amount of smoke. 
- Rapid cooling system (Cold Trap) used to remove moisture for analyzing pure gas. 
- Pressure (DPT) Line for measuring flow rate and Gas Sampling for gas collection. 
- Filtering System for delivering reliable gases with no impurities into the analyzer. 
- Module for data collection (Data Logger, DAQ System). 
- PC for auto control and data monitoring. 
- MFC(Mass Flow Controller) for automatically controlling the flow of propane gas. 
- Auto Valve System for opening/closing propane gas. 
- Ignition System for auto-ignition. 


specification

Product nameISO 9705 Room Corner Burning Testing Equipment For Building Materials
control waycomputer
Power220VAC 3A 50Hz
Weight 700KG
ModelGD9705

Company Information:
ISO 9705 Room Corner Burning Testing Equipment for Building Materials