Tub Faucet Infrared Induction Solenoid Valve Fd-Szc

China Tub Faucet Infrared Induction Solenoid Valve Fd-Szc, Find details about China Tub Faucet Switch, Multifunction Valve from Tub Faucet Infrared Induction Solenoid Valve Fd-Szc

Model NO.
FD-SZC
Structure
Single Hole
Function
Induction, Magnetization
Functional Design
Double Handle, Single Handle, Lifting, Revolving
Number of Handles
Single Handle
Capacity
6 Quart
Certification
CE, RoHS, CB
Trademark
Fuxin
Transport Package
Carton
Specification
Ordinary
Origin
Prc
HS Code
8481802190
Model NO.
FD-SZC
Structure
Single Hole
Function
Induction, Magnetization
Functional Design
Double Handle, Single Handle, Lifting, Revolving
Number of Handles
Single Handle
Capacity
6 Quart
Certification
CE, RoHS, CB
Trademark
Fuxin
Transport Package
Carton
Specification
Ordinary
Origin
Prc
HS Code
8481802190

Sensor Sanitary Ware Faucet Solenoid Valve FD-160PC
New Type 2021 Low Water Hammer and Sea Water Function .


The valves are applied in the automatic system for Infrared faradic sanitary of faucet, Urinal flusher and so on. There are three cavities in the valve body to adjust the pressure ,reduce the resistance when the valve core is moving in the cavity ,also absorb the impact of medium to valve body while switching. Which improve the stability of valve and extend the service life, narrow the pulse width upon the max or min pressure . Special self-clean feature makes the easy anti-blocking ability .

Technical Feature  160 series

Instruction
 
Rated VoltageDC3VDC6VDC12VDC24V
Coil resistance10Ω15.5Ω36Ω130Ω
Min current300mA258mA250mA138mA
Switch modeDC pulse(latching type)
 
Pulse width20-40ms
Operating pressure0.02Mpa-0.8Mpa
Media temperature1ºC--75ºC
Responding timeOpen ≤0.3s  close≤1s
Pressure(Mpa)0.020.050.10.20.30.40.50.60.70.8
Flow(L/min)0.59.716.323.528.23235.638.94244.9
Performance test 
Strength testWater pressure 2.5MPa/1min
No-load testVoltage 3.6V pulse width 20msPermissible limiting voltage V*1.15
High water pressure start and closeAt water pressure 0.8MPa,voltage DC4.5V,pulse width 20ms,the solenoid valve can be started and closed normally
low water pressure start and closeAt water pressure 0.02MPa,voltage DC4.5V,pulse width 20ms,the solenoid valve can be started and closed normally
Leakage upon high water pressure1.2MPa without leakage
Leakage upon low water pressure0.02Mpa leakage≤0.1ml/min
Electric strengthAmong conductive part, mounting hole and nonconductive metal, it can withstand 500V/50Hz,leakage current 0.75mA for 1 min without the breakdown
Insulation resistanceThe resistance between the charged part and nonconductive metal part tested by megohm meter of 500V ≥20MΩ
 
 
 
Sealing test
 
 
 
Static pressure
AirHigh pressure1MPa
   Low pressure0.02MPa
  Cold waterHigh pressure1.2MPa
   Low pressure0.02MPa
  Hot waterHigh pressure0.8MPa
   Low pressure0.02MPa
Service life≥1000000 cycles(CJ/T 194-2004)

Requirements of working environment
Temp of working environment1ºC--60ºCPermissible limiting pressure(water)≤1.2MPa
Humidity of working environment35%-90% RHMounting directionIt is mounted in vertical. The inclination do not exceed 15 degrees
Storage temp-5--80ºC( no freezing state)Storage humidity25%--95% RH(No condensation state)