Automatic Hot Water Spray Sterilizer Retort

China Automatic Hot Water Spray Sterilizer Retort, Find details about China Autoclave, Retort Sterilizer from Automatic Hot Water Spray Sterilizer Retort

Model NO.
GT7C 2000
Designed Pressure of Autoclave
0.35mpa
Design Temperature
147 Degree C
Working Temperature
121 Degree C
Usage
Canned Food, Glass Jar, Pouch
Origin
Wenzhou China
Model NO.
GT7C 2000
Designed Pressure of Autoclave
0.35mpa
Design Temperature
147 Degree C
Working Temperature
121 Degree C
Usage
Canned Food, Glass Jar, Pouch
Origin
Wenzhou China
Automatic Hot Water Spray sterilizer Retort

Usage:
This sterilizer is widely used for the high-temperature sterilization in foodstuff, beverage, soft can, medical needle and etc. Especially for second sterilization for foodstuff which packed in pouch or flexible bag.

Water spray resorts is by direct injection steam, heat up the water of the hot water tank to the predetermined temperature, and then injection process tank, and make the process water pot continuously circulation, and through the water vapor mixer heating sterilization cycles. So as to shorten the sterilization time, improve work efficiency. Sterilization process water can be recycled, save the consumption of energy, time and manpower and material resources and reduce the production cost.

Characteristics
1. This equipment are new type products which developed by double sterilization kettle extension, its sterilization effect is the same as the double sterilization kettle, output 1 times higher than it.
2. Sterilization with hot water can be used in circulation between the two sterilization kettles; Users can greatly reduce the investment cost.
3. Use the screen can touch control
4. Pressure, temperature, sterilization time are automatic control, it's more accurate than manual control.
5. Pressure and temperature data in digital displayed on the touch screen.
6. With the temperature, pressure, curve record function and can print at any time.

Automatic Hot Water Spray Sterilizer Retort
Automatic Hot Water Spray Sterilizer Retort

Wenzhou wanyuan food machinery factory- - Autoclave sterilizer retort
The below is autoclave sterilizer retort specification
ModelGT7C 720 GT7C 1200GT7C 2000 GT7C 2400
CategoryElementary Pressure Vessel
Internal Diameter (mm)900100011001200
Volume( m³)1.223.54.2
Design Temperature143 degree C
Working Temperature123 degree C
Design Pressure0.3 MPa
Working Pressure0.15 MPa
Working Mediumwater\steam\compressed air
Main Pressure Part MaterialSS304
Welding Coefficient0.7
Corrosion Allowance1mm
Net Weight(kg)600110017002000
External Dimensions(mm)length2100280037004000
Width1300145016001600
height1650170018001900