Dry Method Distribution Laser Diffraction Particle Size Analysis Analyzer Analyze

China Dry Method Distribution Laser Diffraction Particle Size Analysis Analyzer Analyze, Find details about China Particle Size Analyze, Particle Size Analyzer from Dry Method Distribution Laser Diffraction Particle Size Analysis Analyzer Analyze

Model NO.
CY-2012
Light Source
High Performance He-Ne Laser (λ= 632.8nm
Output Parameter
D10, D50, D90, D100, S/V Referent Parameters
Max Diameter of Workpiece
<500mm
Mass Scope of Workpiece
<900kg
Maxcapacity
>1000kn
Accuracy Grade
0.5
Load Way
Electronic Load
Loading Method
Dynamic Load
Display
Needle
Control
Computer Control
Weight
0-100kg
Power Source
AC220V
Trademark
CYEEYO
Transport Package
Carton
Specification
75cm*65cm*70cm
Origin
Shan Dong
HS Code
9027500090
Model NO.
CY-2012
Light Source
High Performance He-Ne Laser (λ= 632.8nm
Output Parameter
D10, D50, D90, D100, S/V Referent Parameters
Max Diameter of Workpiece
<500mm
Mass Scope of Workpiece
<900kg
Maxcapacity
>1000kn
Accuracy Grade
0.5
Load Way
Electronic Load
Loading Method
Dynamic Load
Display
Needle
Control
Computer Control
Weight
0-100kg
Power Source
AC220V
Trademark
CYEEYO
Transport Package
Carton
Specification
75cm*65cm*70cm
Origin
Shan Dong
HS Code
9027500090
            dry method Laser Distribution Particle Analyzer TesterDry Method Distribution Laser Diffraction Particle Size Analysis Analyzer Analyze
Product Description

 

Dry Method Distribution Laser Diffraction Particle Size Analysis Analyzer AnalyzeTechnique parameter

1,Measurement range:0.1-600 u m

2,Error:< ± 1% ( national standard materials D50)

3,repetitiveness deviation:< ± 1% ( national standard materials D50)

4,Electrical requirement:AC 220 ± 10 V, 50 Hz, 200w

5,Dimensions:950 X 330 X 300 mm

6,Weight:40 kg

Working Principle

    The Laser particle size analyzer accords to the international standards ISO-13320 and the Full range Mie Scattering Theory.  The data of particles are calculated from the changes of scattering luminous intensity of different particles in different angles in consideration of the refractive index of the particles and dispersion medium.

The data of particles are calculated in two ways:  unconstrained fitting inversion and constrained fitting inversion.

    The constrained fitting inversion is a relatively simple way. The particle size distribution is inverted in the assumed rule of the particles. But the deviation exists between the assumption and reality, and the tested results through the constrained fitting inversion can not really reflect the true size distribution of the particles.

    In unconstrained fitting inversion way, no particles are assumed before the test, and the size distribution of the dust clusters is precisely calculated directly from the luminous intensity. In this way, the instrument requires high performance, reasonable sensor design and size grading. The particle size distribution are precisely calculated with Rise Laser particle size analyzer which uses the optimized  non-uniform cross 3D  fan shaped sensor array and the reasonable size.

Technical characteristics

    Basis of the stable test: The stability of the tested data is ensured by the stable optical signals from the system. The Rise Laser particle size analyzer uses He-Ne gas laser light source of 0.6328 micron wavelength. It works to offer stable laser source signals, and serves more than 25000 hours.

   

 

Specifications

 

Dispersion method

Specifications

Dimensions

Weight(Net)

CY-2002

Wet

1,measurement range:0.1-600μm

2,Error:1%(national standard materials D50)

3,Repetitiveness deviation: 1%(national standard                       materials D50)

1000×330×320mm

38kg

CY-2006

Wet

1,Measurement range:0.05-800μm

2,Error:1%(national standard materials D50)

3,Repetitiveness deviation: 1%(national standard materials D50)

CY-2008

Wet

1,Measurement range:0.02-1200μm

2,Error:1%(national standard materials D50)

3,Repetitiveness deviation: 1%(national standard materials D50)

CY-2009

Wet

1,Measurement range:0.02-2600μm

2,Error:1%(national standard materials D50)

3,Repetitiveness deviation: 1%(national standard materials D50)

 

 

CY-2012

Dry

       1,Measurement range:0.1-600μm

        2,Error:1%(national standard materials D50)

3,Repetitiveness deviation: 1%(national standard materials D50)

Main system: 1000×330×320mm

Dry sampling system:350×330×300mm

40kg

CY-2016

Dry

1,Measurement range:0.1-800μm

       2,Error:1%(national standard materials D50)

3,Repetitiveness deviation: 1%(national standard materials D50)

CY-2018

Dry

1,Measurement range:0.1-1200μm

        2,Error:1%(national standard materials D50)

3,Repetitiveness deviation: 1%(national standard materials D50)

CY-2019

Dry

1,Measurement range:0.1-2600μm

        2,Error:1%(national standard materials D50)

3,Repetitiveness deviation: 1%(national standard materials D50)

CY-2022

Wet/

Dry

1,Measurement range:0.1-600μm/

2,Error:1%(national standard materials D50)

3,Repetitiveness deviation: 1%(national standard materials D50)

Main system: 1000×330×320mm

Dry sampling system:350×330×300mm

Wet sampling system:350×330×300mm

 

50kg

CY-2026

Wet/

Dry

1,Measurement range:0.05-800μm(wet)

0.1-800μm(dry)

2,Error:1%(national standard materials D50)

3,Repetitiveness deviation: 1%(national standard materials D50)

CY-2028

Wet/

Dry

1,Measurement range:0.02-1200μm(wet)

0.1-1200μm(dry)

2,Error:1%(national standard materials D50)

3,Repetitiveness deviation: 1%(national standard materials D50)

CY-2030

Wet/

Dry

2,Measurement range:0.02-2600μm(wet)

0.1-1200μm(dry)

2,Error:1%(national standard materials D50)

3,Repetitiveness deviation: 1%(national standard materials D50)

Dry Method Distribution Laser Diffraction Particle Size Analysis Analyzer Analyze

 

Packaging & Shipping

Dry Method Distribution Laser Diffraction Particle Size Analysis Analyzer Analyze

Our Advantages

Dry Method Distribution Laser Diffraction Particle Size Analysis Analyzer Analyze

FAQ

Dry Method Distribution Laser Diffraction Particle Size Analysis Analyzer Analyze