Vertical Flame Spread Flammability and Heat Release Tester

China Vertical Flame Spread Flammability and Heat Release Tester, Find details about China Vertical Flame Spread Tester, Flame Spread Tester from Vertical Flame Spread Flammability and Heat Release Tester

Model NO.
FIPEC
Gas Supplies
Propane and Compressed Air
Dimension of Wide Ladder
500(W) ×3, 500(H) mm
Dimension of Standard Ladder
800(W) ×3, 500(H)
Dimension of Exhaust Hole
300±30(W)X1,000±100(D)
Function
Vertical Flame Spread and Heat Release Measuring
Test Object
Cable and Wires
Trademark
AI
Transport Package
Plywood Case
Specification
Stainless steel
Origin
China
HS Code
9031809090
Model NO.
FIPEC
Gas Supplies
Propane and Compressed Air
Dimension of Wide Ladder
500(W) ×3, 500(H) mm
Dimension of Standard Ladder
800(W) ×3, 500(H)
Dimension of Exhaust Hole
300±30(W)X1,000±100(D)
Function
Vertical Flame Spread and Heat Release Measuring
Test Object
Cable and Wires
Trademark
AI
Transport Package
Plywood Case
Specification
Stainless steel
Origin
China
HS Code
9031809090

Introduction

EN 50399 specifies the tester and methods of test for the assessment of vertical flame spread, heat release and smoke production of vertically-mounted bunched wires or cables, electrical or optical, under defined conditions. EN 50399 details the apparatus and the arrangement and calibration of the instrumentation to be installed in order to measure the heat release and the smoke production during the fire test. Test procedures to be used for type approval testing for classification of cables in Euroclasses B1ca, B2ca, Cca and Dca are given.

EN 50399 Bunched Cable Flammability and Heat Release Tester is consist of IEC 60332-3 tester, heat release measurement, smoke density measurement and modified air inlet system. This is accomplished by fitting a small instrumented section of ducting into the exhaust system of the rig and using this with associated gas analysis instrumentation and software. The duct section houses all gas sampling probes, temperature and mass flow probes and has ports for the smoke measuring system.

 


Features
1.Test chamber has the dimension of 1,000±100(W) x 2,000±100(D) x 4,000±100(H) mm. The bottom surface of the test chamber is higher than the ground while the rear side is supplemented with insulated material to insulate it from heat.

2.At the lower section of the test chamber, there is a 800±20(W) x 400±10(D) sized hole at the 150±10mm position from the front side of the chamber to supply the air.

3.There is a 300±30(W)x1,000±100(D) sized exhaust hole at the rear corner of the top section of the test chamber to allow emission of the smoke during the test.

4.A flame trap is installed at the front side of the burner of the vertical flame spread tester to prevent backfire by propane to ensure the utmost safety.

5.Unlike the conventional IEC60332-3 equipment, the vertical flame spread tester records all control and test conditions with the computer to add user friendliness.

6.If stop the excessive combustion test due to Water Spray device installed for extinguish.

7.The program on the requirement on standard and 70,000Btu/h can be program.

8.Wide stainless steel ladder dimensions: 500(W) ×3, 500(H) mm.

9.Standard stainless steel ladder dimensions: 800(W) ×3, 500(H).

10.The heat measuring system is provided with two sets of standard propane burner and venturi mixtures.
11.Follow the standard category can program for select a test.

12.Exhaust system consists of smoke collection hood,exhaust duct, air inlet system, Centrifugal fan and frequency converter.

13.The duct section houses all gas sampling probes, temperature and mass flow probes and has ports for the smoke measuring system.

14.Paramagnetic oxygen analyzer, using the method of paramagnetic change to measure the concentration of oxygen in the gas. Concentration range of 0-25%.

15.Carbon Dioxide Analyser (infrared) for use in heat release measurement. Concentration range of 0-10%.
16.Soot filter, cold trap, drying column, pump and waste regulators for conditioning the sample gases prior to analysis.

17.Data acquisition system and software are supplied with EN50339 Bunched Cable Vertical Flame Spread Heat Release Smoke Production Tester.



Installation requirements
1Electrical110V AC 60Hz / 230V AC 50Hz, 5A
2Ambient TemperatureOperating 10°C to 35°C
3Gas SuppliesIndustrial propane and compressed air
4Dimension1120 mm (W) x 2200 mm (D) x 5600 mm (H)
5Weight12000KG



Factory overview

Vertical Flame Spread Flammability and Heat Release Tester
Customer Feedback 

Germany
Vertical Flame Spread Flammability and Heat Release Tester
USA
Vertical Flame Spread Flammability and Heat Release Tester
Transporation
Vertical Flame Spread Flammability and Heat Release Tester
FAQ

1.What's the delivery time?

About 2 or 3 months.

2.What's your payment terms?
30% paid by T/T in advance,70% paid by by T/T before shipping.

3.What's your guarantee terms?
The warranty of all products is 1 year.During this period,we are responsible for all faults caused by us.And we can supply life-long technical support. 

4.Can you supply training?
We can supply training in our factory and online training for free.If onsite installation and training are required,please pay for tickets,accommodation and salary USD150/Day for every person.