China 48V 200A Manufacturer Lead Acid Battery Charge and Discharge Capacity Test Equipment Battery Charging Discharging Load Tester Testing Equipment, Find details about China Battery Diacharge Testing, Battery Discharge Tester from 48V 200A Manufacturer Lead Acid Battery Charge and Discharge Capacity Test Equipment Battery Charging Discharging Load Tester Testing Equipment
Suitable Battery | DC 48V |
Model No. | HDCF-4820 |
Discharge Voltage Range | DC32-60V |
Discharge Current Range | 0-200A |
Charge Voltage Range | DC42V-60V |
Charge Current Range | 0-200A |
Working mode | Standalone mode, parallel master mode, parallel slave mode, and remote controlled mode |
Protection performance | Over-voltage protection, under-voltage stop, over-current protection, reverse wiring protection, 65ºC over-temperature protection,-LCD prompt and buzzer alarm |
Cell voltage collection (optional) | Multi-band RF wireless module for communication distance of more than 100m, compatible with 2V/4V/6V/12V cell voltage monitoring, 1-25 groups of RF wireless monitoring modules for monitoring up to 300 batteries, and single wireless monitoring module for monitoring 12 cells |
Control precision | Discharge current≤±1%; group voltage≤±0.1%; cell voltage≤±0.05% |
PC communication | RS485 interface, USB interface |
Work Environment | |
Heat radiation | Forced air cooling |
Temperature | Working rage: -5-50ºC Storage temperature: -40-70ºC |
Humidity | Relative humidity 0-90% (40±2ºC) |
Elevation | Rated elevation of 4,000m |
Noise | <75dB |
Working Power Supply | |
Voltage | Power supply: single-phase AC220V (-20%-+30%), frequency: 45-65Hz; charging power supply: refer to nameplate parameters or case label |
Electric strength test | Input-shell: 2200Vdc 1min Input-output: 2200Vdc 1min Output-shell: 700Vdc 1min |
Safety | Compliance with EN610950 |