China Must Home Use Mini Power Inverter 300W 600W 800W 1000W Price, Find details about China Sine Wave Power Inverter, DC AC Inverter from Must Home Use Mini Power Inverter 300W 600W 800W 1000W Price
EP2000 Rack Series (0.3-1KW)
This manual contains information regarding the installation, operation and use of the equipment.It is advised that this User's Manual be consulted before installation of the equipment, which operation shall only be carried out by qualified personnel. Thereafter, it shall be kept and referred to whenever it is neccessary to carry out work on the equipment.
Features:MODEL | EP20-300W | EP20-500W | EP20-600W | EP20-800W | EP20-1KW |
---|---|---|---|---|---|
Default Battery System Voltage | 12VDC | 12VDC/24VDC | 12VDC/24VDC | 12VDC/24VDC | |
INVERTER OUTPUT | |||||
Reted Power | 300W | 500W | 600W | 800W | 1000W |
Waveform | Pure sine wave | ||||
Nominal Output Voltage RMS | 100V/110V/120VAC 220V/230V/240VAC(±10% RMS) | ||||
Output Frequency | 5OHz/60Hz±0.3 Hz | ||||
Inverter Efficiency(Peak) | >80% | ||||
Line Mode Efficiency | >95% | ||||
Power Factor | 1.0 | ||||
Typical Transfer Time | Typical 2~6ms ,10ms max | ||||
AC INPUT | |||||
Voltage | 220VAC | ||||
Selectable Voltage Range | 96~132VAC 145~275VAC(For Personal Computers) | ||||
Frequency Range | 50Hz/60Hz (Auto sensing 44~68Hz) | ||||
BATTERY | |||||
Nominal Input Voltage | 12VDC | 12VDC/24VDC | 12VDC/24VDC | 12VDC/24VDC | |
Minimum Start Voltage | 10.5VDC /21.0VDC | ||||
Low Battery Alarm | 10.5±0.3V /21.0VDC±0.6V | ||||
Low Battery Cutoff | 10.0VDC±0.3V /20.0VDC±0.6V | ||||
High Voltage Alarm | 15.5VDC±0.3V /31.0VDC±0.6V | ||||
High Battery Voltage Recover | 15.0VDC±0.3V /30.0VDC±0.6V | ||||
CHARGER | |||||
Charger Voltage | 14.0V±0.2/28.0V±0.4 | ||||
Overcharge Protection S.D. | 15.5VDC/31.0VDC | ||||
Maximum Charge Current | 15A~25A | ||||
BYPASS & PROTECTION | |||||
Nominal Input Frequency | 50Hz or 60Hz | ||||
Overload Protection (SMPS Load) | IPS automatically shutdown if overload exceeds 120% ofnormal value for 30 seconds IPS automatically resume work if overload comes back to rated load | ||||
Output Short Circuit Protection | FUSE | ||||
Bypass Breaker Rating | 10A | ||||
Max Bypass Current | 10Amp | ||||
MECHANICAL SPECIFICATIONS | |||||
Dimensions (W*H*D) | 265*120*295mm | ||||
Net Weight (kg) | 7.0kg | 9.5Kg | 10.5kg | 12kg | 12.5kg |
Shipping Dimensions(W*H*D) | 316*185*377mm | ||||
Shipping Weight (kg) | 7.5kg | 10Kg | 11kg | 12.5kg | 13kg |
OTHER | |||||
Operation Temperature Range | 0°C to 40°C | ||||
Audible Noise | 60dB MAX | ||||
Display | LED or LCD Optional | ||||
Standard Warranty | 1 year |
Power Rate(w) | backup time(H) @1*100Ah | backup time(H)@2*100Ah | backup time(H)@4*100Ah | backup time(H)@4*200Ah |
300 | 3.5 | 7 | 14 | 28 |
500 | 2.1 | 4.2 | 8.4 | 16.8 |
600 | 1.75 | 3.5 | 7 | 14 |
800 | 1.3 | 2.6 | 5.2 | 10.4 |
1000 | 1 | 2.1 | 4.2 | 8.4 |