Maxwel manufacture Semi Conducting Tape ( KE40 )

China Maxwel manufacture Semi Conducting Tape (KE40), Find details about China Semi Conductive Tape, Semi Conducting Tape from Maxwel manufacture Semi Conducting Tape (KE40)

Model NO.
KE40
Certification
ISO9001
Color
Black
Brand
Maxwel
Colour
Black
Raw Material
Semi Epr
Function
Shield
Normal Size
25mm*0.76mm*5m
Trademark
Maxwel
Transport Package
100rolls/CTN
Specification
25mmx0.76mmx5m
Origin
Wenzhou
HS Code
5906101000
Model NO.
KE40
Certification
ISO9001
Color
Black
Brand
Maxwel
Colour
Black
Raw Material
Semi Epr
Function
Shield
Normal Size
25mm*0.76mm*5m
Trademark
Maxwel
Transport Package
100rolls/CTN
Specification
25mmx0.76mmx5m
Origin
Wenzhou
HS Code
5906101000
High Voltage EPR Tape (KE40)

Semi-Conducting Tape is high-voltage splicing tape, made from semi EPR(Ethylene Propylene Rubber), they are non-vulcanizing and shelf-stable conductivity over a wide temperature range. Its conductivity is not affected, except by low-viscosity oils.

Features
Semi-conducting (low resistivity) 
Retains conductivity with strength 
Elongates easily to conform to irregular shapes 
Stable at elevated temperatures (130°C / 266°F) 
Compatible with most solid dielectric cable insulations and conductors 
Excellent resistance to cracking or checking from solvents, UV, or moisture
Compatible with high-voltage splicing and terminating materials
Usable for indoor or outdoor applications

Application
1.To electrically round out high-voltage connectors and to bond to insulating materials to minimize electrical stresses 
2.Continue semi-conducting strand shielding found in solid dielectric (polyethylene, XLP, EPR, etc.) cables at 5 kV and above 
3.Provide shielding for cable joints on solid dielectric insulated power cables (shielded or concentric neutral) 
4.Replace semi-conducting layer beneath metallic shield of similar cables in case of damage (screening) 
5. Make conductive portion of stress cone of power cable termination on solid dielectric insulated power cables 
6.Maintain positive connection between concentric neutral semi-conducting jackets of power cables and semi-co
nducting surfaces of plug-in units 
7.Establish a more positive contact between concentric neutral wires and pre-molded devices already installed with too much jacket exposed 
8.Round out bolted connections on insulated bus bars 

Size
19mmx0.76mmx4.5m
25mm X 0.76mm X 5m
Special size available
                                                                               
DescriptionUnitSpec
Tensile StrengthMpa≥1.0
Elongation%≥500
Self Adhesion/Not loose
Thermal Stress Resistance/Pass
UV Exposure Resistance/No cracks
Volume ResistivityΩ\cm≥100~1000