These cables are constructed with a central tube filled with water blocking jelly giving it excellent water
and moisture resistance. Two corrugated steel armouring and two steel wires strengthening with in the
inner PE sheath and an outer PE sheath give this cable excellent tensile strength, mechanical and
environmental protection.
They have small diameter, light weight and installation friendly since they come in a single tube with loose
tube fiber count up to 12 fibers. Their compact construction protects the loose tube from shrinking, the
double armour makes it crush, rodent and impact resistance, the outer PE sheath gives it ultraviolet protection.
This cable is suitable for outdoor distribution through ducts, conduits or aerial pipe lines. They come in larger
delivery length, so can also be used in long distance communication system, service drop cables, building interconnections.Complied With Or Exceeds Standard
. ITU-T G652.D . ITU-T G651.1 OM1 OM2 OM3 OM4
. ITU-T G657.A . IEC60793-2-10 type A1a.1/A1b OM1/OM2
. IEC60793-2-10 type A1a.2 OM3 . IEC60793-2-10 type A1a.3 OM4
. ISO/IEC 11801 , ISO/IEC 24702 . IEEE 802.3z Gigabit Ethernet
. ANSI/TIA/EIA 568C.3 . ROHS Compliant Directive 2011/65/EU(ROHS2.0)Mechanical & Environmental Characteristics ITEM | Value |
Max. Tensile Load (Short Term) | 3000N |
Max. Tensile Load (Long Term) | 1000N |
Max. Crush Load (Short Term) | 1500N/100mm |
Max Crush Load (Long Term) | 500N/100mm |
UL Fire Rated | OFNR |
Operating Temperature | -20°C to +60°C |
Storage Temperature | -40°C to +85°C |
Sheath Material | Standard: PE Optional: LSZH or other |
ANSI/TIA/EIA-598-B Standard Fiber Color CodeFiber Number Fiber Color Fiber Number Fiber Color
Fiber 1 Blue Fiber 7 Red
Fiber 2 Orange Fiber 8 Black
Fiber 3 Green Fiber 9 Yellow
Fiber 4 Brown Fiber 10 Violet
Fiber 5 Slate Fiber 11 Rose
Fiber 6 White Fiber 12 Aqua
Fiber 13 and higher The color code is repeated with added black stripe or dash
Note: Fiber Tube color will be followed with same order.Optical Characteristics
Of all the differences between multimode & singlemode fiber, the most fundamental differences are the
size of the fiber's core and the associated attenuation or loss and bandwidth of the fiber. The smaller the
core diameter, the higher the fiber's bandwidth and the lower the attenuation (loss in dB per kilometer).
The fiber's attenuation and bandwidth are also dependent on wavelength.
Singlemode was for high-speed longdistance transmission and multimode (in either the 50 µm or 62.5 µm
core diameters) was used for lower speed short distance applications. Multimode 50 µm fiber had a lower
cost and higher modal bandwidth than multimode 62.5 µm core fiber. Bandwidth is a measurement of the
data carrying capacity of the fiber. A higher bandwidth fiber carries more data. See table below. Fiber Type | Max. Attenuation (dB/km) | Min.Overfill Launch Bandwidth (Mhz.km) | Min.Gigabit Ethernet Link Distance (m) |
Gigabit | 10Gigabit |
850nm | 1300nm | 1310nm | 1550nm | 850nm | 1300nm | 850nm | 1300nm | 850nnm |
OM1 62.5/125µm | ≤2.7 | ≤0.6 | - | - | ≥500 | ≥600 | 275 | 550 | - |
OM2 50/125µm | ≤2.3 | ≤0.6 | - | - | ≥500 | ≥500 | 750 | 600 | 150 |
OM3 50/125µm | ≤2.3 | ≤0.6 | - | - | ≥1500 | ≥500 | 1000 | 600 | 300 |
OM4 50/125µm | ≤2.3 | ≤0.6 | - | - | ≥3500 | ≥500 | 1100 | 600 | 550 |
G652D 9/125µm | - | - | ≤0.30 | ≤0.18 | - | - | - | - | - |
G657A 9/125µm | - | - | ≤0.35 | ≤0.21 | - | - | - | - | - |
Ordering Information
Part Number: OC-XX-ABCDCL
Ordering Guide XX | A | B | C | D | CL |
Cable Type | Jacket | Fiber/Tube | Fiber Count | Fiber Type(FXX) | Jacket Color(CL) |
GYXTW53 | 1=PVC 2=LSZH 3=PE | 01=01 Fiber/T 02=02 Fiber/T ... 11=11 Fiber/T 12=12 Fiber/T | No. Of Fiber 004F,048F | OM1=62.5/125 OM1 OM2=50/125 OM2 OM3=50/125 OM3 OM4=50/125 OM4 G652D=9/125 G652D G657A=9/125 G657A | As noted in Color code chart |
Ordering SamplePart Number | Description |
OC-GYXTW53-31212G652DBK | 12 cores Singlemode G652D GYXTW53 Fiber Optic Cable, 12 Fiber/Tube, PE jacket, Black color. |