China 22kw Evi Split Air to Water Heat Pump -35degrees Ambient, Find details about China Inverter Heat Pump, Evi Inverter Heat Pump from 22kw Evi Split Air to Water Heat Pump -35degrees Ambient
1) Extended working range down to -35°C ambient (low ambient type)
2) 5 modes: heating only, heating+DHW, cooling only, cooling+DHW, DHW only
3) Low running costs and high efficiency
4) Long-life and corrosion resistant composite cabinet stands up to severe climates
5) Famous compressor ensures outstanding performance and durability
6) Intelligent LCD display with self-diagnostic control function
7) With control output for three-way valve
8) Easy operation and simple installation
9) WIFI control function is optional
The units are supplied with micro processor based digital controller with LCD display. The controller is programmed to provide a maximum protection to the heat pump system and accurate temperature control. The control panel is completely factory wired with all accessories and terminals included.
High corrosion resistance
High thermal efficiency
High working temperature
High efficienty and energy saving
Quiet operation due to less moving parts
Adopt famous brand rotary or scroll compressor
Energy saving pump with constant volume or pressure adjustment function. German Wilo or Chinese Shinoo water pump is optional.
Split Type:
Options: EVI Low Ambient Heat Pump (On-Off, Split & Monoblock Type)
EVI On-Off Low Ambient Heat Pump (Split) | ||||||||
Model | EHP-09S | EHP-13S | EHP-17S | EHP-17S | EHP-22S | EHP-28S | ||
HP | 3 | 5 | 6 | 6 | 8 | 10 | ||
Power supply | Indoor unit | V/Ph/Hz | 220-240/50/1, 380-415/50/3 | |||||
Outdoor unit | V/Ph/Hz | 220-240/50/1 | 220-240/50/1, 380-415/50/3 | |||||
+7°C/35°C Floor heating | Heating capacity | kW/h | 9.5 | 14.0 | 17.0 | 17.0 | 22 | 28.5 |
Power input | kW | 2.6 | 3.4 | 4.1 | 4.0 | 5.1 | 7 | |
+2°C/35°C Floor heating | Heating capacity | kW/h | 8.5 | 12.3 | 15 | 15 | 19.5 | 26 |
Power input | kW | 2.5 | 3.2 | 3.9 | 3.9 | 5.0 | 6.9 | |
-7°C/35°C Floor heating | Heating capacity | kW/h | 6.8 | 10.6 | 12.5 | 12.5 | 16.5 | 22 |
Power input | kW | 2.3 | 3.6 | 4.3 | 4.2 | 5.7 | 7.7 | |
+7°C/45°C Radiators | Heating capacity | kW/h | 9 | 13 | 16 | 16 | 20.5 | 25.5 |
Power input | kW | 2.9 | 3.9 | 4.9 | 4.6 | 6 | 8 | |
-12°C/41°C Floor heating | Heating capacity | kW/h | 5.8 | 9 | 10.5 | 10.5 | 13 | 17 |
Power input | kW | 2.5 | 3.8 | 4.6 | 4.5 | 5.6 | 7.6 | |
+35°C/7°C Fan coil | Cooling capacity | kW/h | 6 | 10 | 11.8 | 11.8 | 20 | 25 |
Power input | kW | 2.3 | 3.6 | 4.5 | 4.4 | 7.4 | 9.6 | |
Heating operation range | Ambient | °C | -25~25 | |||||
Water side | °C | 18~55 | ||||||
Cooling operation range | Ambient | °C | 10~43 | |||||
Water side | °C | 7~22 | ||||||
Domestic hot water operation range | Ambient | °C | -25~25 | |||||
Water side | °C | 25~55 | ||||||
Rated water flow rate | m³/h | 1.6 | 2.4 | 2.9 | 2.9 | 3.8 | 4.9 | |
Rated pressure drop | kPa | 30 | 40 | 45 | 45 | 45 | 40 | |
Max. working pressure | Refrigerant | Bar | 44 | 44 | 44 | 44 | 44 | 44 |
Water | Bar | 7 | 7 | 7 | 7 | 7 | 7 | |
Controller | - | Micro processor based digital wire controller with LCD display | ||||||
External cabinet | - | Galvanized steel with powder coating | ||||||
Compressor | Type | - | Rotary | Scroll | ||||
Qty. | Nos. | 1 | 1 | 1 | 1 | 1 | 1 | |
Refrigerant | - | R410a | ||||||
Water heat exchanger | - | SUS 316 Brazed plate heat exchanger | ||||||
Water pump | - | Wilo/Shinhoo | ||||||
Expansion tank | L | 5 | 8 | 8 | 8 | 10 | 10 | |
Electric heater | kW | 3/6 | 6 | |||||
Water connection | Inlet&Outlet | inch | 1" | 1" | 1" | 1" | 1" | 1-1/4" |
Noise level | Indoor Unit | dB(A) | 42 | 42 | 42 | 42 | 42 | 42 |
Outdoor Unit | dB(A) | 52 | 53 | 55 | 55 | 55 | 56 | |
Net dimension (W*D*H) | Indoor Unit | mm | 522*296*863.5 | 522*296*863.5 | 522*296*863.5 | 522*296*863.5 | 522*296*863.5 | 602*308*880 |
Outdoor Unit | mm | 950*445*800 | 976*410*1273 | 940*448*1365 | 940*448*1365 | 1150*480*1565 | 1405*590*1626 | |
Net weight | Indoor Unit | kg | 50 | 50 | 50 | 50 | 50 | 70 |
Outdoor Unit | kg | 55 | 80 | 90 | 90 | 110 | 165 | |
Notes: 1.The values of heating (cooling) capacity/power input/COP (EER) are based on measurement of EN14511 standard. Usage environment, such as operation of the heating equipment, room temp. & controller adjustments, may cause disparities between practically determined and these values; 2.Sound pressure level measured at distance of 1m from the devices; 3.For wall-mounted type, the compressor is located in the outdoor unit. Blueway reserves the rights to modify the above specifications without notice for product improvement. Please contact us for updated information. |
EVI On-Off Low Ambient Heat Pump (Monoblock) | ||||||||
Model | EHP-09M | EHP-13M | EHP-17M | EHP-17M | EHP-22M | EHP-28M | ||
HP | 3 | 5 | 6 | 6 | 8 | 10 | ||
Power supply | V/Ph/Hz | 220-240/1/50 | 380-415/3/50 | |||||
+7°C/35°C Floor heating | Heating capacity | kW/h | 9.5 | 14.0 | 17.0 | 17.0 | 22 | 28.5 |
Power input | kW | 2.6 | 3.4 | 4.1 | 4.0 | 5.1 | 7 | |
+2°C/35°C Floor heating | Heating capacity | kW/h | 8.5 | 12.3 | 15 | 15 | 19.5 | 26 |
Power input | kW | 2.5 | 3.2 | 3.9 | 3.9 | 5.0 | 6.9 | |
-7°C/35°C Floor heating | Heating capacity | kW/h | 6.8 | 10.6 | 12.5 | 12.5 | 16.5 | 22 |
Power input | kW | 2.3 | 3.6 | 4.3 | 4.2 | 5.7 | 7.7 | |
+7°C/45°C Radiators | Heating capacity | kW/h | 9 | 13 | 16 | 16 | 20.5 | 25.5 |
Power input | kW | 2.9 | 3.9 | 4.9 | 4.6 | 6 | 8 | |
-12°C/41°C Floor heating | Heating capacity | kW/h | 5.8 | 9 | 10.5 | 10.5 | 13 | 17 |
Power input | kW | 2.5 | 3.8 | 4.6 | 4.5 | 5.6 | 7.6 | |
+35°C/7°C Fan coil | Cooling capacity | kW/h | 6 | 10 | 11.8 | 11.8 | 20 | 25 |
Power input | kW | 2.3 | 3.6 | 4.5 | 4.4 | 7.4 | 9.6 | |
Heating operation range | Ambient | °C | -25~25 | |||||
Water side | °C | 18~55 | ||||||
Cooling operation range | Ambient | °C | 10~43 | |||||
Water side | °C | 7~22 | ||||||
Domestic hot water operation range | Ambient | °C | -25~25 | |||||
Water side | °C | 25~55 | ||||||
Rated water flow rate | m³/h | 1.6 | 2.4 | 2.9 | 2.9 | 3.8 | 4.9 | |
Rated pressure drop | kPa | 30 | 40 | 45 | 45 | 45 | 40 | |
Max. working pressure | Refrigerant | Bar | 44 | 44 | 44 | 44 | 44 | 44 |
Water | Bar | 7 | 7 | 7 | 7 | 7 | 7 | |
Controller | - | Micro processor based digital wire controller with LCD display | ||||||
External cabinet | - | Galvanized steel with powder coating | ||||||
Compressor | Type | - | Rotary | Scroll | ||||
Qty. | Nos. | 1 | 1 | 1 | 1 | 1 | 1 | |
Refrigerant | - | R410a | ||||||
Water heat exchanger | - | Brazed plate heat exchanger | ||||||
Water pump (optional) | - | Wilo/Shinhoo | ||||||
Expansion tank (optional) | L | 5 | 8 | 8 | 8 | 10 | 10 | |
Electric heater (optional) | kW | 3/6 | 6 | |||||
Water connection | Inlet&Outlet | inch | 1" | 1" | 1" | 1" | 1" | 1-1/4" |
Noise level | dB(A) | 52 | 53 | 55 | 55 | 55 | 58 | |
Net dimension (W*D*H) | mm | 1160*430*820 | 1079*430*1273 | 1079*430*1368 | 1079*430*1368 | 1150*480*1565 | 1405*590*1626 | |
Net weight | kg | 70 | 110 | 110 | 125 | 135 | 210 | |
Notes: 1.The values of heating (cooling) capacity/power input/COP (EER) are based on measurement of EN14511 standard. Usage environment, such asoperation of the heating equipment, room temp. & controller adjustments, may cause disparities between practically determined and these values; 2.Sound pressure level measured at distance of 1m from the device; 3.If local ambient temperature will be below 0°C in winter, please use an approved antifreeze solution. Blueway reserves the rights to modify the above specifications without notice for product improvement. Please contact us for updated information. |
1.Blueway has around 30 years of rich HVAC manufacturing experience.
2.Over 1000 original R&D products, Blueway is qualified to be OEM/OBM/ODM.
3.Over 10000 engineering solutions with great success provided by Blueway.
4.Online technical service is available twenty-four hours a day without break.
5.Blueway intelligent control system with precise timing, temperature control & remote monitoring function.
With advanced technology and R&D capacity, Blueway has obtained over more than 20 patents and become one of the leading HVAC manufacturers in China. Meanwhile, 70% of Blueway products have been exported to oversea markets, including Australia, Europe, North America, Middle East, South Africa, South America and obtained worldwide recognition. Additionally, it has over 20 representative offices located in different cities of China, and also has its authorized distributors in Europe, Middle East, North America and South America.
So far, Blueway has already provided over 10000 engineering solutions with great success. What's more, Blueway is also the recommended brand by Hilton Hotel in Chinese market. Blueway will continue its endeavor and commitment to serve its worldwide partners by providing solutions and innovative products of high efficiency.
Q: Any optional compressor brand?
A: For on/off EVI type, we adopt Panasonic compressor (R410a). For inverter EVI type, Mitsubishi or Panasonic brand (R32/R410a). If you wanna get more details about inverter low ambient heat pump, please kindly refer to the "DC Inverter Heat Pump" series.
Q: How about the package?
A: Carton & export wooden pallet.
Q: What's the refrigerant option?
A: Generally, we adopt R410a for this product.
Q: Any recommended model?
A: EHP-13S is the split type, with built-in water pump, expansion valve & electric heater.
Q: How to be Blueway Authorized Distributor?
A: Please contact us via mail/wechat/whatsapp for further communication.
Q: Coud you indicate the product warranty?
A: One year for the whole unit, three years for the compressor.
Q: How can we contact your distributor?
A: Please kindly let us know your detail contact information, then we will ask related people to contact you in a short time.