Sy2000 Economical Vector Control 3 Phase 380V/400V/415V 5.5kw AC Drive Variable Frequency Drive for Fan and Pump

China Sy2000 Economical Vector Control 3 Phase 380V/400V/415V 5.5kw AC Drive Variable Frequency Drive for Fan and Pump, Find details about China Frequency Inverter, AC Drive from Sy2000 Economical Vector Control 3 Phase 380V/400V/415V 5.5kw AC Drive Variable Frequency Drive for Fan and Pump

Model NO.
SY2000-5R5P-4
Link of Transformation
AC-DC-AC Variable-Frequency Drive
Nature of DC Power
Voltage Variable-Frequency Drive
Function
Simple Type
Brand
Sanyu
Trademark
SANYU
Transport Package
Carton and Wooden
Specification
38.5*38*53
Origin
Shanghai
Model NO.
SY2000-5R5P-4
Link of Transformation
AC-DC-AC Variable-Frequency Drive
Nature of DC Power
Voltage Variable-Frequency Drive
Function
Simple Type
Brand
Sanyu
Trademark
SANYU
Transport Package
Carton and Wooden
Specification
38.5*38*53
Origin
Shanghai
 
Sy2000 Economical Vector Control 3 Phase 380V/400V/415V 5.5kw AC Drive Variable Frequency Drive for Fan and Pump
Sy2000 Economical Vector Control 3 Phase 380V/400V/415V 5.5kw AC Drive Variable Frequency Drive for Fan and Pump
Sy2000 Economical Vector Control 3 Phase 380V/400V/415V 5.5kw AC Drive Variable Frequency Drive for Fan and Pump
Sy2000 Economical Vector Control 3 Phase 380V/400V/415V 5.5kw AC Drive Variable Frequency Drive for Fan and Pump
Sy2000 Economical Vector Control 3 Phase 380V/400V/415V 5.5kw AC Drive Variable Frequency Drive for Fan and Pump
Sy2000 Economical Vector Control 3 Phase 380V/400V/415V 5.5kw AC Drive Variable Frequency Drive for Fan and Pump
Sy2000 Economical Vector Control 3 Phase 380V/400V/415V 5.5kw AC Drive Variable Frequency Drive for Fan and Pump
Sy2000 Economical Vector Control 3 Phase 380V/400V/415V 5.5kw AC Drive Variable Frequency Drive for Fan and Pump
 

Features:

Advanced control technologies include V/F control, advanced VF control, separate VF control, VF square curve control, without PG current vector control
Output frequency up to 999.9HZ
Stable operation and low price, it is a cost-effective and economical product.
Aluminum alloy heat dissipation, compact structure, saving installation space, suitable for various working conditions.
Torque compensation, multiple braking, undervoltage suppression, automatic current limiting and pressure limiting and other functions ensure safe and stable operation.
Standard RS485, MODBUS communication, detachable control panel, remote control
PID, counter, speed tracking and other special functions make the control more abundant.
Complete functions, widely used in fans, pumps and other occasions

Specification:
ItemDescription
InputRated voltage frequency380V or 220V:50HZ/60HZ
Allowable voltage working rangeFluctuation range: ±20%; voltage unbalance rate: <3%; frequency: ±5%
OutputRated voltage0~380V or 0 ~220V
Frequency0~999.9HZ
Overload capacity150% rated current for 1 minute
Main control performanceControl modelV/F control, advanced VF control, separate VF control, VF square curve control, without PG current vector control
ModulationSpace voltage vector PWM modulation
Speed range1: 100 (without PG vector control)
Starting torque150% rated torque at 3.0 Hz (Advanced VF control)
Speed stabilization accuracy±0.2% rated synchronous speed
Speed fluctuation±0.5% rated synchronous speed
Torque response50ms without PG vector control
Torque controlSupport torque control without PG vector control mode
Torque control accuracy:±5%
Frequency accuracyDigital setting: maximum frequency×±0.01%;
Analog setting: maximum frequency×±0.2%
Frequency resolutionDigital setting: 0.01Hz;
Analog setting: maximum frequency×0.05%
Torque boostAutomatic torque boost, manual torque boost 0.1%~30.0%
V/F curve6 control modes: 1 user setting V/F curve mode, 4 torque reduction characteristic curve modes (2.0 power, 1.7 power, 1.5 power, 1.3 power) and linear curve, square curve, multi-point VF curve
Acceleration and deceleration curveLinear acceleration and deceleration. Time unit (minutes/second) optional, up to 999.9 seconds
DC brakingStarting frequency of DC braking at stop: 0.00-50.00HZ
Braking time: 0.0-30.0S; braking current: 0.0%-50.0% rated current
Automatic Voltage Adjustment (AVR)When the grid voltage changes, it can automatically keep the output voltage constant
Automatic current limitAutomatically limit the current during operation to prevent frequent overcurrent fault tripping
Voltage stallControl the voltage during deceleration to prevent overvoltage protection from stopping
Automatic carrier adjustmentAutomatically adjust carrier frequency according to load characteristics and temperature characteristics; multiple carrier modes are optional
Customization functionSeparate VF controlEasy to implement various power supply designs
Textile swing frequencyTextile swing frequency control, can realize fixed swing frequency and variable swing frequency .
Frequency combination functionThe running command channel and frequency reference channel can be combined arbitrarily
JogThe jog forward rotation frequency can be set and the jog priority is enabled. The jog frequency range: 0.00Hz~50.00Hz; the jog acceleration and deceleration time can be set from 0.1 to 999.9s, and the jog interval time can be set from 0.1 to 999.9s .
Multi-speed operationAchieve multi-speed operation through built-in PLC or control terminal
Built-in process closed-loop controlCan easily form a closed-loop control system.
Water supply burst detectionBurst detection delay time, high pressure detection threshold, low pressure detection threshold
Operation functionRun command channelOperation panel. Bolt terminal, serial communication port, can be switched in various ways
Frequency given channel2 kinds of digital setting, analog voltage setting, analog current setting, pulse setting, terminal setting, multi-speed setting, etc.
Auxiliary frequency settingAchieve flexible auxiliary frequency fine-tuning and frequency synthesis
Pulse output terminal0~50kHz pulse square wave signal output, can realize the output of physical quantities such as set frequency and output frequency
Analog output terminal2 analog signal outputs. The output range is flexibly set between 0~20mA or 0~1OV, which can realize the output of physical quantities such as set frequency and output frequency
Operating
Panel
LED displayCan display 26 parameters such as set frequency, output frequency, output voltage, output current, etc.
Key function selectionDefine the action range of some keys to prevent misoperation
Protective functionPhase loss protection (optional), over-current protection, over-voltage protection, under-voltage protection, over-temperature protection. Overload protection, load loss protection, etc.
EnvironmentLocationIndoor. Free from direct sunlight, dust, corrosive gas, flammable gas, oil mist, water vapor, dripping or salt etc.
AltitudeUse derating above 1000 meters, derate 10% for every 1000 meters raised
Ambient temperature-10C~+40C (If ambient temperature is 40C-50C, please use derating)
Humidity5%~95%RH, no condensation
VibrationLess than 5.9m/s( 0.6g)
Storage temperature-40C~+70C
StructureProtection levelIP20
Cooling methodAir-cooled, with fan control
 Efficiency7.5KW and below>93%
   

Model Selection
Sy2000 Economical Vector Control 3 Phase 380V/400V/415V 5.5kw AC Drive Variable Frequency Drive for Fan and Pump
Input voltageModelCapacityInput CurrentAdapted motor
(KVA)(A)(KW)
220V 1-phaseSY2000-0R7G-S21.440.75
SY2000-1R5G-S22.671.5
SY2000-2R2G-S23.8102.2
SY2000-004G-S28.8164
SY2000-5R5G-S211225.5
380V 3-phaseSY2000-0R7G-41.52.30.75
SY2000-1R5G-43.73.71.5
SY2000-2R2G-44.752.2
SY2000-004G/5R5P-45.9/8.910.5/14.64/5.5
SY2000-5R5G/7R5P-48.9/1114.6/205.5/7.5
SY2000-7R5G/011P-411/1520/27.57.5/11
     

Dimension and Installation:
Sy2000 Economical Vector Control 3 Phase 380V/400V/415V 5.5kw AC Drive Variable Frequency Drive for Fan and Pump

 
ModelDimension(mm)net weight
WHDW1H1D1φd(kg)
SY2000-0R7G-S2100151141.589140129.551.1
SY2000-1R5G-S2100151141.589140129.551.1
SY2000-2R2G-S2100151141.589140129.551.1
SY2000-004G-S212021516510820215552
SY2000-0R7G-4100151141.589140129.551.1
SY2000-1R5G-4100151141.589140129.551.1
SY2000-2R2G-4100151141.589140129.551.1
SY2000-004G-412021516510820215552
SY2000-5R5G-412021516510820215552
SY2000-7R5G-412021516510820215552
         


Wiring and Diagram:

Sy2000 Economical Vector Control 3 Phase 380V/400V/415V 5.5kw AC Drive Variable Frequency Drive for Fan and Pump

Panel:
Sy2000 Economical Vector Control 3 Phase 380V/400V/415V 5.5kw AC Drive Variable Frequency Drive for Fan and Pump