Thermal Cycle Chamber Humidity Temperature Test Chamber with Inner Glass Door Handle Holes

China Thermal Cycle Chamber Humidity Temperature Test Chamber with Inner Glass Door Handle Holes, Find details about China Test Chamber, Environmental Test Chamber from Thermal Cycle Chamber Humidity Temperature Test Chamber with Inner Glass Door Handle Holes

Model NO.
KMH-408E
Weight
100-500Kg
Power Source
AC380V
Temp. Range
-20°c~+150°c or -68°f~+302°f
Humidity Range
20-98%R.H.
Temp. Constancy
+/-0.5oc
Humidity Constancy
+/-2.5%R.H.
Temp. Uniformity
+/-2.0oc
Humidity Uniformity
+/-3.0%R.H.
Heat up Time
-20oc~ +100oc Within 35mins
Pull Down Time
+20 Oc~-20 Oc Within 45mins
Equipment Power
7.5kw
Trademark
KOMEG
Transport Package
Strong Plywood Case, Meet International Standards
Specification
Standard and customs made
Origin
Dongguan, China
HS Code
90321000
Model NO.
KMH-408E
Weight
100-500Kg
Power Source
AC380V
Temp. Range
-20°c~+150°c or -68°f~+302°f
Humidity Range
20-98%R.H.
Temp. Constancy
+/-0.5oc
Humidity Constancy
+/-2.5%R.H.
Temp. Uniformity
+/-2.0oc
Humidity Uniformity
+/-3.0%R.H.
Heat up Time
-20oc~ +100oc Within 35mins
Pull Down Time
+20 Oc~-20 Oc Within 45mins
Equipment Power
7.5kw
Trademark
KOMEG
Transport Package
Strong Plywood Case, Meet International Standards
Specification
Standard and customs made
Origin
Dongguan, China
HS Code
90321000
Aplications
Temperature and Humidity Test Chamber is able to provide rapid product temperature change rates and use varying levels of relative humidity to locate design problems prior to shipping your products, improving product quality and reliability.

Standard configuration
Sight window*1, cable port(portΦ 50mm)*1, shelves*2, chamber lamp*1, power cable *2m
No fuse breaker, over pressure, over heat and over current protection for compressor,
Over temperature protection, over load protect of blower, dry heat protection

KOMEG Advantages
Thermal Cycle Chamber Humidity Temperature Test Chamber with Inner Glass Door Handle HolesThermal Cycle Chamber Humidity Temperature Test Chamber with Inner Glass Door Handle HolesThermal Cycle Chamber Humidity Temperature Test Chamber with Inner Glass Door Handle HolesThermal Cycle Chamber Humidity Temperature Test Chamber with Inner Glass Door Handle HolesThermal Cycle Chamber Humidity Temperature Test Chamber with Inner Glass Door Handle HolesThermal Cycle Chamber Humidity Temperature Test Chamber with Inner Glass Door Handle HolesThermal Cycle Chamber Humidity Temperature Test Chamber with Inner Glass Door Handle HolesThermal Cycle Chamber Humidity Temperature Test Chamber with Inner Glass Door Handle HolesThermal Cycle Chamber Humidity Temperature Test Chamber with Inner Glass Door Handle Holes
1)More heating, cooling and air flow capacity than other models bring you to temperature quickly and with better uniformity
2)Responsive expansion valve and by pass refrigerant control put all of the refrigeration horsepower to work for you
3)Maintenance is simplified with full three sided access to base mounted system components
All models available with cyrogenic cooling
4)CE Certification on most KMH Models

Optional accessories
Cable Port: Φ 100mm cable port is available
Shelves
Ro-type water purifier: R-80/day
Provide to keep the humidifying heater and wet bulb wick free from scale.
Inner glass door with operation port
A glass door can be provided behind the main door so that specimens can be observed. Two operation ports of 130mm diameter are used for handing specimens inside the chamber without opening the glass door.
Dehumidifier
The rotation regenerating dehumidifier M-120 ensures precise control of low humidity (5º C 5%RH) for electrostatic reliability tests.
Temperature and humidity recorder
-100 to +150º C/0 to 100%RH 100mm with effective width 100mm and 2 pen
Temperature 1 pen and humidity 1 pen.
-100 to +150º C/0 to 100%RH 100mm with effective width 100mm and 6 dots
Temperature 3 dots and humidity 1 dot.
-100 to +150º C/0 to 100%RH 100mm with effective width 180mm and 12 dots
Temperature 6 dots and humidity 6 dots.
Defrosting circuit
The chamber automatically detects and melts the frost on the evaporator when operating below 0º C.
Liquid or infection
In order to rapidly decrease the temperature inside the chamber, a cylinder of liquid can be connected the chamber.


After-service
Thermal Cycle Chamber Humidity Temperature Test Chamber with Inner Glass Door Handle Holes
If you face any problems in future during testing process we promise we will give you a reply within 48 hours and solution provide within 3 working days. We can offer operation video and English operation muanual. We can provide video-conference. If customers require on-site service, the transport and travel expense shall be borne by customer.
Environmental Temperature and Humidity Chamber
Secifications ( at +20ºC room temp.  Or+25ºC water temp with empty load)
ModelKMH-R seriesKMH-L seriesKMH-S series
150R225R408R800R1000R150L225L408L800L1000L225S408S800S1000S
Temp. range -20ºC~150ºC -40 ºC~+150ºC -70ºC~+150ºC 
Interior sizelW(mm)600700700100010006007007001000100070070010001000
H(mm)600700750100010006007007501000100070075010001000
D(mm)460480800800100046048080080010004808008001000
Exterior sizeW(mm)880980980128012808809809801280128098098012801280
H(mm)17301890194021602160173018901940216021601890194021602160
D(mm)14001460174017501950140014601740175019501460174017501950
Power(KW)5.867.512.812.87.57.58.514.514.59.510.618.518.5
Weight(KG)240280400500580250300420530600330450550650
Humidity uniformity±3.0 % R.H±5.0 % R.H±3.0 % R.H±5.0 % R.H±3.0%R.H±5.0 % R.H
Heat up time -20ºC~+100ºC,within 35 min -40ºC~+100ºC, within 45 min -70ºC~+100ºC,within 60 min
Pull down time +20ºC~-20ºC, within 45 min +20ºC~-40ºC , within 60 min +20ºC~-70ºC,within 80 min
Standard accessoriesSight window*1,  cable port(portΦ50mm)*1,   shelves*2,    chamber lamp*1,    power cable *2m
Safety device  (standard)No fuse breaker, over pressure \ over heat and over current protection for compressor,
Over temp. protect, over load protect of blower, dry heat protection
Control SystemBalanced Temperature & Humidity Control System
Refrigeration systemAir Cooled  ( Water Cooled Type is option )
Hermetic compressor,Single stage refrigeration system,                          CFC-Free refrigerant(HFC-507/HFC-23)Hermetic compressor, Cascade Refrigeration ,             CFC free refrigerant                           (HFC-507/HFC-23)
ControllerPanel:7-inch LCD Touch panel,    Chinese or English display selectable
Operation model :Program or fix point running
Memory capacity :120programs,1200steps,
All repeat 999 cycles, part repeat 99 cycles
Humidity Range20 ~ 98 % R.H
Temp. constancy±0.5ºC   
Humidity constancy±2.5 % R.H
Temp. uniformity±2.0ºC
Interior materialStainless Steel Plate ( SUS 304 )
Exterior materialBaked Painting Steel Or Stainless steel(SUS304)
Insulation materialRigid polyurethane Foam and Glass Fiber Wool
Ambient Temp.+5ºC~+35ºC
Wiring method AC 380±10 %  50Hz ,3 phase 4 wires +Ground Wires
Note: 1. We reserve the right to change specifications without prior notice 2. Customized sizes and configurations available