Product Description
Model | BK-EA201 | BK-EA301 | BK-EA401 | BK-EA501 |
Measuring Range: | HC 0~10000×10-6(ppm)vol CO: 0~10×10-2(%)vol
| HC 0~10000×10-6(ppm)vol CO: 0~10×10-2(%)vol NOx: 0~5000×10-6(ppm)vol | HC 0~10000×10-6(ppm)vol CO: 0~10×10-2(%)vol CO2: 0~20×10-2(%)vol O2: 0~25×10-2(%)vol
| HC 0~10000×10-6(ppm)vol CO: 0~10×10-2(%)vol CO2: 0~20×10-2(%)vol O2: 0~25×10-2(%)vol NOx: 0~5000×10-6(ppm)vol |
Indicating Error | HC±12×10-6(ppm)vol CO±0.06×10-2(%)vol
| HC±12×10-6(ppm)vol CO±0.06×10-2(%)vol NOx±25×10-6 (ppm)vol | HC±12×10-6(ppm)vol CO±0.06×10-2(%)vol CO2±0.5×10-2(%)vol O2±0.1×10-2(%)vol
| HC±12×10-6(ppm)vol CO±0.06×10-2(%)vol CO2±0.5×10-2(%)vol O2±0.1×10-2(%)vol NOx±25×10-6 (ppm)vol |
Stability | Moment drift≤±3% | |||
Repeatability | ≤±2% | |||
Response time | 95% response is not more than 10 seconds | |||
Preheating time | 8min ( preheating 3min emergency detection ) | |||
Power supply | AC 110/220V±10%,50/60Hz | |||
Packing Size | 680 (L )×385(W)×265(H)mm | |||
Gross Weight | 12kg |