KONNEN AIR SOURCE HEAT PUMP, AIR TO WATER HEAT PUMP, COMMERCIAL USE:
* Panasonic compressor & R410a refrigerant, OR Copeland compressor and R417a refrigerant;
* Stainless steel 304 for all fasteners, for side covers of evaporator;
* Preservative oil for copper tubes and all important part of cabinet;
* Chinese No.1 brand "ND" shell & tube heat exchanger;
* Japan "Saginomiya"  or "Sanhua" electronic expansion valve;
* "Sanhua" 4-way valve;
* "Schneider" AC contactor & Relay
* LCD controller;
* Delivery time: 20~25 days;
* Payment term: T/T 30% in advance and T/T 70% before delivery;
* Warranty time: 24 months after delivery.

WE SUPPLY OEM SERVICE!

KONNEN NEW FACTORY(HEAT PUMP + WATER TANK + CONTROLLER):
Home Use Water Heater (circulating heating)
WHY US:
Home Use Water Heater (circulating heating)
KONNEN NEW PROJECTS:
Home Use Water Heater (circulating heating)
WORLD FAMOUS BRANDS WE COOPERATED FOR OUR HEAT PUMPS:
Home Use Water Heater (circulating heating)
KONNEN HEAT PUMPS LOADING:
Home Use Water Heater (circulating heating)
PARAMETERS TABLE:

 A02H series (Air source heat pump water heater circulation type)                                                                                                                                          
 HW03Ps-E3HW05Ps-E5HW03P-E3 HW05P-E5HW07P-E5HW10P-C24HW14P-C24HW20P-C48HW24P-C48HW30P-C48HW36P-C48HW48P-C96
Rated heating capacitykW12191219253550 7585105125165
Rated input powerkW2.75 4.39 2.75 4.37 5.75 8.10 11.57 17.20 19.60 24.20 28.90 38.10 
Rated input currentA14.05 23.10 5.17 8.34 10.77 15.00 23.86 31.80 37.00 46.10 53.50 72.30 
Maximum input powerkW3.38 5.40 3.38 5.38 7.07 9.96 14.23 21.16 24.11 29.77 35.55 46.86 
Maximum input currentA18.28 29.19 6.43 10.21 13.44 18.93 27.05 40.20 45.81 56.56 67.54 89.04 
Performance coefficient(COP)/4.36 4.33 4.36 4.35 4.35 4.33 4.32 4.36 4.34 4.34 4.33 4.33 
Rated hot water output temp.ºC55 
Max. hot water output temp.ºC60 
Rated hot water produce capacityL/H258408258408537752.510751612.51827.52257.52687.53547.5
Power supply1N 220V/50Hz3N 380V/50Hz
CompressorTypeFully closed scroll type
Start ModeDirectly start
QuantitySet111112242334
Water side heat exchangerTypeShell & coil(tube) heat exchanger
Water flowm3/h2.1 3.3 2.1 3.3 4.3 6.0 8.6 12.9 14.6 18.1 21.5 28.4 
Water Pressure DropkPa≤50≤55≤50≤55≤55<60<60<65<65<65<65<65
Pipe sizeDNDN20DN25DN20DN25DN25DN32DN32DN50DN50DN50DN65DN80
Protections1. High pressure and low pressure protection, 
2. Anti-freezing protection, 
3. High temperature protection, 
4. Too big of the water temperature difference for outlet and inlet protection, 
5. Overload protection, 
6. Lack phase protection, 
7. Reverse phase protection, etc.. 
RefrigerantThrottle TypeElectronic expansion valve
Quantitykg1.92.81.92.84.12.8×24.1×23.2×47.6×26.2×37.6×37.6×4
NoiseDB(A)≤55≤63≤55≤63≤65≤65≤68≤70≤72≤73≤74≤78
Dimensionmm700×680×
875
820×695×
1060
700×680×
875
820×695×
1060
820×695×
1060
1000×1000×18581000×1000×18581000×2050×19001000×2050×19001000×2050×19801000×2050×19802000×2050×1980
Net Weightkg1001601001601903104006056508358401230
Testing conditions: 
1. Application side initial water temperature: 15ºC, end temperature 55ºC, max. temperature 60ºC.
2. Ambient temperature dry bulb 20ºC, wet bulb 15ºC. 
The above parameters are based on Refrigearnt R410a, for parameters based on other refrigerant please contact us.
The above parameters may have some differences from the final product because of products updating, so above information is not the provision of any business contract. Please refer to final product label when buy, or refer to us for any information. Our company keeps the right to interpret.
Domestic Air Source Heat Pump Water Heater
Air Source Heat Pump
Air to water Heat Pump
Air-source heat pump Cycling Water Heater Home Use Series:
Suitable for households of 2-13 people
By creating comfortable living conditions
So that you can enjoy
Hot water bath
And fashionable life
In your own house

Features:
Split-type design and independent water tanks for flexible and convenient connection of water pipes.
Flexible installation of main unit and water tank.
Dynamic heat exchange between water and coolant as there is no coolant pipe in the water tank. This will reduce the damping of the heat exchanger and thus ensure adequate flow of water, prevent leakage caused by corrosion of copper tube, and reduce scale formation in the system.
Free selection of water tank sizes.
Stainless steel water tank with good insulation and less scale formation to ensure the quality of water.
Isolated water and electricity system to ensure operating safety.
Constant Outlet Water Temperature

Water temperature can be set between 40 degrees and 60 degrees, with an difference of less than 1degrees. The outlet temperature can be easily controlled and the adjustment will cause no significant change in water temperature. Whether the outlet quantity is increased or decreased, the water temperature will remain unchanged.

The RL series can produce constant temperature water no matter how the flow is adjusted. In the case of common gas water heaters, the water temperature will change when the flow is adjusted. The temperature will go down when the outlet flow is decreased; Otherwise, it will go up. A sudden rise in water temperature may cause skin burns. When the water flow is too small, the heater may be choked off. For those with a complicated pipe system, the water temperature will be more difficult to control.

Convenient Use of Hot Water.
Air Source Heat Pump Domestic Type (circulation type)
                              Model                                    ParameterKXRS-3.5 IHKXRS-5.0 IHKXRS-7.0 IHKXRS-9.0 IH
Rated Heating capacity   (KW)3.5579
Rated outlet hot water quantity (L/H)75107150193
Outlet water rated temp  ( C )55
Outlet water max temp  ( C )60
Electricity Parameter Rated power   (KW)0.91.241.712.26
Rated current   (A)4.15.67.810.3
Power supply220V~/50HZ
Max power   (KW)1.251.582.252.72
Max current    (A)5.77.210.312.4
RefrigerantR410a(R134a/R407c/R22)
Dimensions mm950*360*5601010*360*630
Weight KG 40606772
Waterproof gradeIPX4
Defend electric shock gradeGRADE 1
Noise Db50Db 53Db 
CompressorPanasonic
Testing Conditions           Ambient Temperature              Water Inlet/Outlet Temp.
Dry Bulb Temp.Wet Bulb Temp.Water Inlet Temp.Water Outlet Temp.
20C15C15C55C
 
Water Tank
Specifications150L200L300L500L
Pipe size (mm)2 x DN152 x DN20
Water Tank Sizeφ470 x 1390φ520 x 1535φ620 x 1455φ700 x 1775
Installation floor type
Concurrent User3-4 people4-5 people6-8 people10-13 people