China 40 TPH Asphalt Mixing Plant Easy to Install and Disassemble, Find details about China Batch, Cold Feeder from 40 TPH Asphalt Mixing Plant Easy to Install and Disassemble
Equipment Name | Asphalt mixing plants |
Rated production capacity | 40t/h |
Model | QCQ40 |
Rated working condition | Asphalt mix is medium grain size (AC-20) |
Aggregate Specification | |
Pass through 40mmscreen | 100% |
Pass through 3mm screen | 40% |
Dryer drum outlet temperature | 160ºC |
Ambient atmospheric pressure | 760 mmHg |
Ambient temperature | 20ºC |
Aggregate density | 1650 kg/m3 |
Aggregate moisture content | ≤5% |
Aggregate specific heat | 0.21 Kcal/kgºC |
Powder content | 5% |
Asphalt content | 5% |
Fuel calorific value | |
Heavy oil | 9,850 Kcal/kg |
Diesel | 10,500 Kcal/kg |
Electrical Design | |
Single phase | 220v |
Three phase | 380v |
Frequency | 50HZ |
Productivity | 40t/h | |
Feeding bin volume | 1200kg | |
Mixture output | 1.8t/bin | |
Agg. size | <=50mm | |
Agg. bins | 3 bins, single volume:5m3, cumulative measurement | |
Weighing range and precision | Agg. | ≤2000kg±2.5% |
Filler | ≤200kg±2.0% | |
Bitumen | ≤200kg±2.0% | |
Products temp | 120~170 ºC, (adjustable) |
No. | Item name | Technical parameter | |
1 | rated capacity | 40t/h(working standard) | |
2 | charge-in capacity | 1.2 m3 | |
3 | charge-in weighting | 1.8t/hodful | |
4 | out-put temp | 120-170ºC(Adjustable) | |
5 | applicability | Bitumen, asphalt dinas, asphalt sand | |
6 | fuel consumption | fuel oil:5.5-7.5kg/t | |
7 | drying drum rotate speed | 20.2 Turn/min | |
8 | assort total power | 153.5kW(Wet dust filter,Asphalt tank) 165.5kW(Bag dust removal system,Asphalt tank) | |
9 | mixer power | 22 kw ×2 | |
drum-drive power | 18.5 kw (Variable frequency starting) | ||
burner power | 7 kw | ||
fan power | Wet dust filter (22 kw) Bag dust removal system(45KW) | ||
coarse ash power | 5.5kw | ||
aggregate elevate power | 7.5 kw | ||
asphalt tank power | 11 kw | ||
filler screw conveyor power | 3 kw | ||
finished product elevate power | 7.5 kw | ||
aggregate weight conveyor power | 5.5 kw | ||
air compressor power | 11 kw | ||
submersible pump | 5.5kw×2 | ||
10 | control-drive way | PLC Programmable electrical control | |
11 | Measuring precision | aggregate | ±2.5% |
filler | ±2% | ||
bitumen | ±2% | ||
12 | Power | voltage | A.C 380V |
frequency | 50HZ |