High Voltage Dynamic Response Test HV Circuit Breaker Analyzer

China High Voltage Dynamic Response Test HV Circuit Breaker Analyzer, Find details about China High Voltage Test, Dynamic Response Test from High Voltage Dynamic Response Test HV Circuit Breaker Analyzer

Model NO.
GDKC-15A
Operating temperature
-20ºC~+50ºC
Trademark
HV Hipot
Transport Package
Wooden Case
Specification
ISO, SGS
Origin
Wuhan China
HS Code
9030849000
Model NO.
GDKC-15A
Operating temperature
-20ºC~+50ºC
Trademark
HV Hipot
Transport Package
Wooden Case
Specification
ISO, SGS
Origin
Wuhan China
HS Code
9030849000
High Voltage Dynamic Response Test HV Circuit Breaker Analyzer
General Information

High voltage circuit breaker is one of the most important control equipment in the power system. GDKC-15A is used to test the dynamic characteristics of high voltage circuit breaker. It is easy to operate, with high accuracy.

 


Features
  1. Embedded industrial control computer. The main board is based on the CortexTM-A8, the main frequency is 1GHz and the flash memory is 1GB. The booting speed is only 16 seconds. 8.4-inch color screen, windows operating system, intuitive user-friendly interface, touch screen, support for Chinese and English input, easy to operate.
  2. High-speed thermal printer facilitate field printing of test data.
  3. Internal integrated power supply, no need for on-site secondary power supply, easy to use. Can provide DC10 ~ 260V adjustable power supply, current is 20A. Arbitrarily set the action voltage of the opening and closing coils, and can be used for low-voltage action test of circuit breaker.
  4. Equipped with a linear sensor, a rotation sensor, a universal sensor and a bracket, and a special fixed multifunctional joint, the installation is extremely convenient and simple.
  5. Applicable to all models of domestic and foreign production of SF6 switches, GIS combination appliances, vacuum switches, oil switches.
  6. Switch action once, get all the data and graphics.
  7. The host can store 30000 sets of field test data (extensible memory card), real-time clock inside the machine, easy to archive.
  8. Equipped with U disk interface, can directly save the data to U disk, upload it to the computer for analysis and storage.
  9. Able to measure 12 metal contacts, 6 main contacts, 6 auxiliary contacts, 6 closing resistor and 3(6) double-end grounded switch at the same time.
  10. Including enveloping line, through the numeric value of multi switch test (2-10) to generate standard enveloping line, carry out analysis and comparison, the analysis of switch vibration frequency can also be carried out.
  11. Fully automatic motor energy storage, motor power measurement function.
  12. Internal anti-interference circuit can meet the reliable use of 800KV substation.


 

Specifications

Timing measurement

12 contacts Inherent open (close) time

Open (close) in phase synchronization

Open(close) phase-to-phase synchronization

Close (open) bounce time (number of bounce)

Test range: 0.01ms to 18000ms, resolution: 0.01ms

Double-end grounded switch measurement

3(6) contacts Inherent open (close) time

Open (close) in phase synchronization

Close (open) bounce time and waveform

Velocity measurement

Just open (just close) velocity

Specified time period (travel or angle) average velocity

 Velocity measurement range

1mm sensor 0.01~25.00m/s

0.1mm sensor 0.001 to 2.50m/s

0.5°angle sensor 1 wave cycle / 0.5°

Travel measurement

Moving contact travel (travel)

Contact travel (open distance)

Travel overshoot and return (over-travel)

Sensor: 50mm, Resolution: 0.1mm

360 line sensor: 360º, resolution: 0.5º

Optional sensor: 300mm, 1000mm, acceleration sensor

Current display

Maximum current 30A, resolution: 0.01A

Instrument power supply

AC/DC 220V±10%; 50Hz±2%

DC power output

DC power output: DC20~260V continuously adjustable, DC110V≤30A (short-term), DC220V≤20A (short-term)

External trigger voltage

AC/DC10-300V, current≤120A

Isolated switch measurement range

Voltage output: DC10~260V (adjustable);

Power output time: 0.01-20 seconds (can be set);

The maximum acquisition time of the fracture signal is 200 seconds;

Measurable fracture open, close time, three phases different period, bounce time and time

Measurable fracture open, close time, three phases different period, bounce time and time

Host volume

360*260*170mm

Operating Environment

-20ºC~+50ºC


High Voltage Dynamic Response Test HV Circuit Breaker Analyzer
High Voltage Dynamic Response Test HV Circuit Breaker Analyzer
High Voltage Dynamic Response Test HV Circuit Breaker Analyzer