China SA2100 Portable Power Quality Analyzer with Hamonic Function, Find details about China Power Quality Analyzer, Power Meter from SA2100 Portable Power Quality Analyzer with Hamonic Function
Measurement Modes
1. Scope - View the voltage/current waveform and readings. Cursor Zoom function.
2. Dips & Swells - Capture the abnormal Event, such as Swells, Dips, Interruptions and Rapid Voltage change
3. Unbalance - Check the unbalance in 3 phases based on IEC61000-4-30 standards
4. Transients - Capture waveforms at high-resolution during a variety of disturbances, maximum 100 events, sample rate 20Ks/s
SpeficiationMeasurement Range | Resolution | Accuracy | ||
Voltage/Current/Frequency | ||||
Vrms(AC+DC) | 1 ~ 1000Vrms | 0.1Vrms | ±0.5% of nominal voltage | |
Vpk | 1 ~ 1400Vpk | 0.1Vpk | ±0.5% of nominal voltage | |
V(Crest Factor) | 1.0 ~ >2.8 | 0.01 | ±5% | |
Arms (AC) | 10mV/A | 0~ 100A | 0.1A | ±0.5% ± 0.2A |
1mV/A | 1~1000A | 0.1A | ±0.5% ± 0.2A | |
50mV(65mV)/1000A | 15~ 5000A | 1A | ±1% ± 2A | |
A(Crest Factor) | 1 ~ 10 | 0.01 | ±5% | |
Frequency | 42.5 ~ 57.5Hz (50Hz nominal) | 0.01Hz | ±0.01Hz | |
51 ~ 69Hz (60Hz nominal) | 0.01Hz | ±0.01Hz | ||
385~414Hz (400Hz nominal) | 0.01Hz | ±0.1Hz | ||
Dips & Swells | ||||
Vrms1/2 | 0 ~ 200% of nominal voltage | 0.1Vrms | ±1% | |
Arms1/2 | 1 ~ 3000A | 1A | ±1% ±2A | |
Duration | hour-minute-second-microsecond | 0.5 cycle | 1 cycle | |
Harmonic(IEC61000-4-7) | ||||
Harmonic Number | 1 ~ 50 | |||
Harmonic Voltage %f | 0.0 ~ 100.0% | 0.10% | ±0.1% ± nx0.1% | |
Harmonic Current %f | 0.0 ~ 100.0% | 0.10% | ±0.1% ± nx0.1% | |
THD | 0.0 ~ 100.0% | 0.10% | ±2.5% | |
Phase | -360° ~ 0° | 1° | ± nx1.5° | |
Power and Energy | ||||
Active Power/Apparent Power/Reactive Power | 1.0 ~ 20.00MW | 0.1kW | ±1.5±10 digits | |
KWh | 0.00kWh ~ 200GWh | 10Wh | ±1.5±10 digits | |
Power Factor | 0 ~ 1 | 0.01 | ±0.03 | |
Flicker (IEC61000-4-15) | ||||
Pst(1min),Pst,Plt,PF5 | 0.00 ~ 20.00 | 0.01 | ±5% | |
Unbalance | ||||
Voltage | 0.0 ~ 5.0% | 0.10% | ±0.5% | |
Current | 0.0 ~ 20.0% | 0.10% | ±1% | |
Voltage Phase | -360° ~ 0° | 1° | ±2digits | |
Current Phase | -360° ~ 0° | 1° | ±5digits | |
Voltage Transient | ||||
Vpk | ±6000Vpk | 1V | ±15% | |
Vrms | 10 ~ 1000Vrms | 1V | ±2.5% | |
Min. Test Time | 50us | |||
Inrush Current | ||||
Arms | 0~3000Arms | 0.1 | ±1% ± 5digits | |
Inrush Duration | 6s ~ 32min selectable | 10ms | ±20ms | |
Logger | ||||
Recording | user-defined parameters for 4 phases at the same time | |||
Memory | Data stored in Micro SD card, 8GB | |||
Duration Time | 2 hrs to 1 year, depends on the recording items and time interval | |||
Interval | 1s to 1 hrs | |||
Monitor | ||||
Support EN50160 in default or user-defined standard |
Channel(Voltage/Current) | 4/4 | ||||
Voltage Range | 1-1000Vrms, 6000V transient voltage | ||||
Current Range | depends on supplied current clamp | ||||
Micro SD card(bulid-in) | 8GB | ||||
Battery | NI-MH, 3800Ah/>7h | ||||
interface | USB Host, LAN | ||||
Screen | 5.6' TFT LCD with resolution320*240(SA2100) | ||||
Language | 9-Chinese, English, French, German, Korean, Polish, Portuguese , Spanish, Turkish | ||||
Dimension/Weight | 262*173*66mm/1.6kg | ||||
Wire Combinatios | 1Ø+NEUTRAL,1Ø SPLIT PHASE,1Ø IT NO NEUTRAL,3Ø WYE, 3Ø DELTA, 3Ø IT, 3Ø HIGH LEG, 3Ø OPEN LEG, 2-ELEMENT, 2 1/2-ELEMENT | ||||
Electrical Safety | IEC61010-1 ,Safety Degree: 600V CAT IV 1000V CAT III |