China 120W Single Output Switching Power Supply, Find details about China Switching Power Supply, Power Supply from 120W Single Output Switching Power Supply
Model / Specification | S-120-12 | S-120-15 | S-120-24 | S-120-48 | |
DC output voltage | 12V | 15V | 24V | 48V | |
Output voltage error (Note2) | ± 1% | ± 1% | ± 1% | ± 1% | |
Rated output current | 10A | 8A | 5A | 2.5A | |
Output current rage | 0-10A | 0-8A | 0-5A | 0-2.5A | |
Wave and noise(Note3) | 120mVp-p | 125mVp-p | 150mVp-p | 150mVp-p | |
Inlet stability(Note4) | ± 0.5% | ± 0.5% | ± 0.5% | ± 0.5% | |
Load stability(Note5) | ± 0.5% | ± 0.5% | ± 0.5% | ± 0.5% | |
DC output power | 120W | 120W | 120W | 120W | |
Efficiency | 80% | 81% | 83% | 84% | |
Adjustable range for DC voltage | ± 10% | ± 10% | ± 10% | ± 10% | |
AC input voltage range | 88~132VAC/ 176~264VACselected by switch 47~63Hz; 255~370VDC | ||||
Input current | 2.6A/115V 1.3A/230V | ||||
AC impulse current | Cold-start current 30A/115V 60A/230V | ||||
Leakage current | < 1mA/240VAC | ||||
Overload protection | 105%~150%Type: TOLDBACK Reset: auto recovery | ||||
Over-voltage protection | ^ ^ | ||||
High-temperature protection | ^ ^ | ||||
Temperature coefficient | ± 0.03% degrees Celsius (0~50 degrees Celsius) | ||||
Setup rise hold up time | 200ms, 50ms, 20ms | ||||
Vibration | 10~500Hz, 2G 10min. /1cycle, Period for 60min, Each axes | ||||
Withstand voltage | Input and output interval: 1.5KvAC Input and enclosure: 1.5KvAC Output and enclosure: 0.5KvAC | ||||
Isolation resistance | Input and output interval: Input and enclosure, Output and enclosure: 500VDC/100 M Ω | ||||
Working temperature and humidity | -10 degrees Celsius~+60 degrees Celsius, 20%~90%RH | ||||
Store temperature and humidity | -20 degrees Celsius~+85 degrees Celsius, 10%~95RH | ||||
Overall dimension | 199*98*38mm | ||||
Weight | 0.66Kgs | ||||
Safety standards | UL1012 TUV 60950( IEC950, UL1950) | ||||
EMC standards | CLSPR22(55022), IEC801-2, 3, 4, IEC555-2 | ||||
Note: 1. The testing condition for the parameter above is: 230VAC input, rated load, 25 degrees Celsius 70%Rh, Humidity 2. Error, include the setting error, line stability and load stability. (Note: 5) 3. Wave test: adopting" A12" double wire for 20MHz, and 0.1uF& uF capacitor short-circuit for interrupting 4. Inlet voltage stability test: when is over load, the lowest voltage of inlet is representative to the highest voltage. 5. Load stability test: The load is from 0% to 100%, others 60%. 6. C2, 3, 11must be knocked down. |