China 60W 24V 2.5A AC to DC Industrial Model Dr-60-24 DIN Rail Switching Power Supply 24 Volt 2.5 Ampere LED Power Driver, Find details about China Switching Power Supply, Switched-Mode Power Supply from 60W 24V 2.5A AC to DC Industrial Model Dr-60-24 DIN Rail Switching Power Supply 24 Volt 2.5 Ampere LED Power Driver
Wenzhou Funelec Electric Co., Ltd. is a high-tech enterprise which is engaged in the design, development, production switching power series products. we are a professional manufacturer of power supplies ,all of our products have approved CE CB and ISO9001.
The EFC capacitors and our own transformers make our products have 3 years warranty,The payment terms which we accept L/C T/T westion union and paypal !
We get a good feedback from our customers ,what we want to do is make your business easy ,
We accept OEM and Sample order,MOQ IS 1PC .
Here take 30W for example !
MODEL | DR-60-5 | DR-60-12 | DR-60-15 | DR-60-24 | |
DC VOLTAGE | 5V | 12V | 15V | 24V | |
RATED CURRENT | 6.5A | 4.5A | 4A | 2.5A | |
CURRENT RANGE | 0-6.5A | 0-4.5A | 0-4A | 0-2.5A | |
RATED POWER | 32.5W | 54W | 60W | 60W | |
RIPPLE & NOISE (max.) Note.2 | 80mVp-p | 120mVp-p | 120mVp-p | 150mVp-p | |
OUTPUT | VOLTAGE ADJ. RANGE | 4.75-5.5V | 11.1 -13.2V | 13.5-16.5V | 21.6-26.4V |
VOLTAGE TOLERANCE Note.3 | ±2.0% | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
LOAD REGULATION | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
SETUP, RISE TIME | 100ms, 30ms/230VAC 200ms, 30ms/115VAC at full load | ||||
HOLD UP TIME (Typ.) | 100ms/230VAC 23ms/115VAC at full load | ||||
VOLTAGE RANGE | 88 - 264VAC 124-370VDC | ||||
FREQUENCY RANGE | 47 ~ 63Hz | ||||
INPUT | EFFICIENCY (Typ.) | 76% | 82% | 83% | 84% |
AC CURRENT (Typ.) | 1.2A/115VAC 0.8A/230VAC | ||||
INRUSH CURRENT (Typ.) | COLD START 18A/115VAC | 36A/230VAC | |||
OVERLOAD | 105 -160% rated output power | ||||
PROTECTION | Protection type: Constant current limiting, recovers automatically after fault condition is removed | ||||
OVERVOLTAGE | 5.75-6.9V | 13.8-16.2V | 17.25-20.25V | 27.6-32.4V | |
Protection type: Shut down o/p voltage, re-power on to recover | |||||
WORKING TEMP. | -20 - +60'C (Refer to "Derating Curve") | ||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | ||||
ENVIRONMENT | STORAGE TEMP., HUMIDITY | -40 ~ +85'C, 10 ~ 95% RH | |||
TEMP. COEFFICIENT | ±0.03%/-C(0~50-C) | ||||
VIBRATION | 10 - 500Hz, 2G 10min./1 cycle, period for60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6 | ||||
SAFETY STANDARDS | UL60950-1, TUV EN60950-1 approved, Design refer to EN50178 | ||||
SAFETY & | WITHSTAND VOLTAGE | l/P-0/P:3KVAC | |||
EMC | ISOLATION RESISTANCE | l/P-0/P:100M Ohms / 500VDC / 25'C/ 70% RH | |||
(Note 4) | EMC EMISSION | Compliance to EN55011, EN55022 (CISPR22) Class B, EN61000-3-2,-3 | |||
EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2, EN61204-3, heavy industry level, criteria A | ||||
MTBF | 216.2K hrs min. MIL-HDBK-217F (25"C) | ||||
OTHERS | DIMENSION | 78*93*56mm (W*H*D) | |||
PACKING | 0.3Kg; 48pcs/15.4Kg/1.02CUFT | ||||
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 To of ambient temperature. | |||||
2.Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1 uf & 47uf parallel capacitor. | |||||
3.Tolerance : includes set up tolerance, line regulation and load regulation. | |||||
NOTE | 4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. |