China Handheld Homecare Wrist Portable Patient Monitor Link with Phone Laptop, Find details about China Patient Monitor, Portable Patient Monitor from Handheld Homecare Wrist Portable Patient Monitor Link with Phone Laptop
Display: 2.4'' LCD screen (Resolution: 320*240)
ECG Leads: 3 Leads
ECG Range: 20bpm up to 250bpm
ECG Abnormal detection: Tachycardia, Bradycardia, VPB, SVPB, VTAC, RonT, Escape beat, Sinus arrest, Bigeminy and Trigeminy
Respiration Range: 0bpm up to 120 bpm
Blood pressure Measurement: SBP, DBP and MAP
Blood pressure Range: 30mmHg up to 280mmHg
SpO2 Range: 40% up to 99%
Pulse Rate Range: 30 times/min up to 240times/min
Resist electric shock : CF type
Build-in: 3.7V 1000mh
Power adapter: 5V/1A The 5V/1A 2W battery charger:
Power: 2W
Type:Non-AP / APG type Do not prevent inlet device
Work environment:
Temperature: 5 ºC~40 ºC
Humidity: 15% ~80%
Atmospheric pressure: 80kPa ~105kPa
Storage environment:
Temperature : -20 ºC ~55ºC
Humidity : 10%~90%
Atmospheric pressure : 50.0 kPa ~106.0kPa
6.1 ECG
ECG waveform gain: 0.5 mm / mV, 1.0 mm / mV, 2.0 mm / mV
Scanning speed : 7.5mm / s, 15mm / s
Heart rate and alarm range :
Adult: 30 bpm ~250 bpm (beats / min)
Precision of ECG: ±5%
Resolution: 1 bpm (Times/Minute)
Sensitivity: >200uV (Peak-to-Peak Value)
Trigger level threshold: 200nV (Lead II)
Resistance of differential input: >5MΩ
Common-mode rejection ratio : ≥ 90 dB
Electrode polarization voltage range: 300mV
Leakage current: <10uA
Input signal range: ±5mV
ECG abnormal types:
Tachycardia, Bradycardia, VPC, Bigeminal rhythm, Tirgeminal rhythm, RonT, VTAC, Escape Beat and Sinus arrest.
Alarm:
The voice audible alarm and screen visual alarm display dual alarm, under review.
Heart rate alarm range: 30~250 bpm
Alarm Mute: Less than 10 seconds
Alarm sound pressure: 45 to 65 db
Frequency response :
Flter : 0.67 Hz ~ 40Hz
Guardianship : 0.05 Hz~40Hz
Detection: 0.05 Hz~100Hz
Calibration signal : 6 mm / mV
ST segment measurement:
Measured range: -2.0mV~+2.0mV
Precise: -0.8mV~+0.8mV; ±0.02mV or±10%
Renew period: 10s
Pacing pulse suppression :
Range: ± 2mV to 500Mv
Width: 0.1ms ~ 2ms
Rise time: 10us ~ 100 μs
Inhibition of the pacing pulse detector for fast ECG signal : 2.5V/s
Can inhibit the T-wave amplitude: > 5mV
6.2 Respiratory
Measuring range : 0bpm ~ 80bpm
Measurement accuracy : ± 5%
6.3 Noninvasive blood pressure (NIBP)
Measurement: Oscillometric pressure when the blood
pressure measurement.Pressurized
automatic calibration zero
Measuring range : 30mmHg~280mmHg
Measurement accuracy : ±5mmHgor ±5%
Maximum cuff pressure: Cuff pressure does not exceed 300 mmHg,
The cuff pressure at 15 mmHg or more time is not
more than 3min.
Overvoltage protection: Yes
Alarm: Systolic / diastolic alarm error of ± 2 mmHg
Atrial premature functi
Measuring wrist Week 135mm ~ 215mm
6.4 Oxygen saturation (SpO2)
Measuring range : 40% ~ 99%
Measurement accuracy: 90% ~ 99% Tolerance ± 2%
70% ~ 89% Tolerance ± 4%
40% ~ 69% Tolerance ± 6%
Alarm range : 50% ~ 99%
6.5 Pulse rate
Measuring range : 30 Beats / min ~ 80 Beats / min ± 2
80 Beats / min ~150 Beats / min ± 4
150 Beats / min ~240 Beats / min ,± 5
Measurement accuracy: ± 5%
6.6 Size and Weight
Dimensions : 7cm (W) × 7cm (H) ×2.6cm (D) (does
not include a wrist strap)
Net Weight : 130g
Gross Weight: 0.5Kg