490 KW hot selling industrial flooded type screw water chiller
1. High Efficiency2. Reliable Operation3. Intelligent Control
4. Easy Installation and Maintenance
5. Non-Standard Design AvailablesignProfile: SANHER SHKL-Y series flooded type screw chiller is an energy-saving and high-efficiency central air-conditioning chiller which designed and manufactured by SANHE. All SANHE chillers are factory tested under load conditions to ensure easy installation for users. The unit adopts a high-efficiency oil separator with the impacts and intercepts oil separation technology. The evaporator adopts the ejector oil return technology. That makes the EER above 5.2, and the EER of the variable frequency flooded chiller can reach 7.0.This series is suitable for various industrial and civil buildings such as hotels, restaurants, shopping malls, hospitals, factories, etc.Features:1. High Efficiency- Using flooded type evaporator, saving energy by 15%~25% compared with similar dry type evaporator chillers.
- Using screw compressor, high efficiency heat-exchanger and electronic expansion valve, four components matched perfectly which make high efficiency of whole unit.
2. Reliable Operation- 7 safeguards can ensure the chiller stable operation.
- All chillers are tested by safety inspection system before delivery, to ensure the performance.
3. Intelligent Control- Intelligent microcomputer controller, provides simplest and thoughtful operation interface, send feedback of maintenance information timely.
- The chiller control system can be connected to the user's central control system, user can check the operation status at any time.
4. Easy Installation and Maintenance- The chiller is filled with refrigerant and lubricating oil before leaving the factory. The user only needs to connect the inlet and outlet pipes and the power supply to run.
- The control interface directly displays the fault item, which is convenient for timely know the faults and elimination.
5. Non-Standard Design Available- We provide R22,R407,R134a refrigerant options according to customer needs.
- We can also produce the special chillers such as anti-corrosion and explosion-proof units according to the customer's request.
Technical DataModel SHKL- | 400WSY | 490WSY | 540WSY | 610WSY | 740WSY | 850WSY | 970WSY | 1090WSY | 1180WSY | 1310WSY | 1600WSY | 1850WSY |
Refrigerant | R22 | R134a | R22 | R134a | R22 | R134a | R22 | R134a | R22 | R134a | R22 | R134a | R22 | R134a | R22 | R134a | R22 | R134a | R22 | R134a | R22 | R134a | R22 | R134a |
Nominal cooling capacity | ×1000kcal/h | 341.4 | 274.3 | 421.3 | 296.6 | 464.3 | 337.9 | 522.8 | 411.9 | 638 | 470.3 | 732.6 | 534.8 | 832.3 | 607.1 | 939 | 655.2 | 1014.6 | 725.7 | 1126.4 | 806.5 | 1374 | 880.5 | 1592.4 | 999.1 |
KW | 397 | 319 | 490 | 345 | 540 | 393 | 608 | 479 | 742 | 547 | 852 | 622 | 968 | 706 | 1092 | 762 | 1180 | 844 | 1310 | 938 | 1598 | 1024 | 1852 | 1162 |
USRT | 113 | 91 | 139 | 98 | 154 | 112 | 173 | 136 | 211 | 156 | 242 | 177 | 275 | 201 | 310 | 217 | 336 | 240 | 372 | 267 | 454 | 291 | 527 | 330 |
Input power | kw | 67.4 | 51.2 | 82.2 | 56 | 88.8 | 63.6 | 101.3 | 77.8 | 124.5 | 87.9 | 141 | 98.7 | 158.5 | 111.6 | 179.2 | 121.1 | 191.9 | 139.1 | 211.9 | 153.6 | 263 | 168.8 | 304 | 190.9 |
Comp.current(A) | 121.8 | 93.5 | 150.7 | 107.9 | 164.7 | 124.1 | 189.8 | 143.7 | 224 | 162.5 | 250 | 178.6 | 287 | 210 | 324 | 210 | 347 | 260 | 385 | 289 | 469.4 | 306.7 | 539.3 | 354.1 |
Power Supply | 3Phase-380V-50Hz | |
Protection Device | Reverse phase protection,phase loss protection,overcurrent protection,high and low voltage protection,low temperature protection,water flow protection |
Number Of Refrigeration Circuit | 1 |
Capacity Control(%) | stepless Capacity or 0,25,50,75,100 | stepless Capacity or 0,25,50,75,100 |
Refrigerant charge | 152 | 122 | 188 | 132 | 207 | 151 | 233 | 184 | 285 | 210 | 327 | 239 | 372 | 271 | 419 | 292 | 453 | 324 | 503 | 360 | 613 | 393 | 711 | 446 |
Condenser | Shell-and-Tube Type |
Water Side max Pressure(MPa) | 1 |
Dia.of pipe to Condenser(inch) | 4″ | 4″ | 5″ | 5″ | 5″ | 6″ | 6″ | 6″ | 8″ | 8″ | 8″ | 8″ |
Cooling Water Flow (m³/h) | 79.9 | 63.7 | 98.4 | 69 | 108.1 | 78.5 | 122 | 95.8 | 149 | 109.2 | 170.8 | 123.9 | 193.7 | 140.6 | 218.6 | 151.9 | 235.9 | 169.1 | 261.7 | 187.7 | 320 | 205.1 | 370.8 | 232.7 |
Condenser Water Pressure drop( Kpa) | 70 | 72 | 75 | 77 | 79 | 80 | 83 | 85 | 90 | 95 | 100 | 106 |
Evaporator | Flooded Type |
Water Side max Pressure(MPa) | 1 |
Dia.of pipe to Evaporator(inch) | 4″ | 4″ | 5″ | 5″ | 5″ | 6″ | 6″ | 6″ | 8″ | 8″ | 8″ | 8″ |
Chilled Water Flow(m³/h) | 68.3 | 54.9 | 84.3 | 59.3 | 92.9 | 67.6 | 104.6 | 82.4 | 127.6 | 94.1 | 146.5 | 107 | 166.5 | 121.4 | 187.8 | 131 | 202.9 | 145.1 | 225.3 | 161.3 | 274.8 | 176.1 | 318.5 | 199.8 |
Evaporator Water Pressure drop(KPa) | 75 | 76 | 78 | 79 | 80 | 82 | 85 | 88 | 95 | 100 | 107 | 110 |
Running noise Db(A) | 65 | 60 | 66 | 61 | 67 | 62 | 69 | 64 | 70 | 65 | 72 | 67 | 73 | 68 | 73 | 68 | 76 | 70 | 76 | 70 | 78 | 72 | 78 | 72 |
Total Weight(kg) | 1540 | 1420 | 1780 | 1650 | 2010 | 1950 | 2550 | 2410 | 2930 | 2760 | 3540 | 3320 | 4050 | 3840 | 4640 | 4450 | 5360 | 5200 | 6100 | 6000 | 6800 | 6500 | 7200 | 7000 |
Running Weight(kg) | 1850 | 1700 | 2140 | 1980 | 2410 | 2340 | 3060 | 2890 | 3520 | 3310 | 4250 | 3980 | 4860 | 4610 | 5570 | 5340 | 6430 | 6240 | 7320 | 7200 | 8160 | 7800 | 8640 | 8400 |
Model SHKL- | 800WDY | 980WDY | 1080WDY | 1220WDY | 1480WDY | 1700WDY | 1940WDY | 2180WDY | 2360WDY | 2620WDY | 3200WDY | 3700WDY |
Refrigerant | R22 | R134a | R22 | R134a | R22 | R134a | R22 | R134a | R22 | R134a | R22 | R134a | R22 | R134a | R22 | R134a | R22 | R134a | R22 | R134a | R22 | R134a | R22 | R134a |
Nominal cooling capacity | ×1000kcal/h | 682.7 | 548.6 | 842.6 | 593.3 | 928.6 | 675.8 | 1045.6 | 823.7 | 1276 | 940.7 | 1465.2 | 1069.6 | 1664.7 | 1214.1 | 1877.9 | 1310.4 | 2029.2 | 1451.4 | 2252.8 | 1613.1 | 2748.1 | 1761 | 3184.9 | 1998.3 |
KW | 794 | 638 | 980 | 690 | 1080 | 786 | 1216 | 958 | 1484 | 1094 | 1704 | 1244 | 1936 | 1412 | 2184 | 1524 | 2360 | 1688 | 2620 | 1876 | 3196 | 2048 | 3704 | 2324 |
USRT | 226 | 181 | 279 | 196 | 307 | 223 | 346 | 272 | 422 | 311 | 485 | 354 | 550 | 401 | 621 | 433 | 671 | 480 | 745 | 533 | 909 | 582 | 1053 | 661 |
Input power | kw | 134.8 | 102.4 | 164.4 | 112 | 177.6 | 127.2 | 202.6 | 155.6 | 249 | 176 | 282 | 197 | 317 | 223 | 358 | 242 | 384 | 278 | 424 | 307 | 526 | 338 | 608 | 382 |
Comp.current(A) | 243.6 | 187 | 301.4 | 215.8 | 329.4 | 248.2 | 379.6 | 287.4 | 448 | 325 | 500 | 357 | 574 | 420 | 648 | 420 | 694 | 520 | 770 | 578 | 939 | 613 | 1079 | 708 |
Power Supply | 3Phase-380V-50Hz |
Protection Device | Reverse phase protection,phase loss protection,overcurrent protection,high and low voltage protection,low temperature protection,water flow protection |
Number Of Refrigeration Circuit | 1 |
Capacity Control(%) | Stepless Capacity or 0,25,37.5,50,62.5,75,87.5,100 | stepless Capacity or 0,25,37.5,50,62.5,75,87.5,100 |
Refrigerant charge | 305 | 245 | 376 | 265 | 415 | 302 | 467 | 368 | 570 | 420 | 654 | 478 | 743 | 542 | 838 | 585 | 906 | 648 | 1006 | 720 | 1227 | 786 | 1422 | 892 |
Condenser | Shell-and-Tube Type |
Water Side max Pressure(MPa) | 1 |
Dia.of pipe to Condenser(inch) | 5″ | 6″ | 6″ | 8″ | 8″ | 8″ | 10″ | 10″ | 10″ | 10″ | 10″ | 12″ |
Cooling Water Flow (m³/h) | 159.7 | 127.3 | 196.8 | 137.9 | 216.3 | 157 | 244 | 191.5 | 298 | 218.4 | 341.5 | 247.9 | 387.4 | 281.2 | 437.2 | 303.7 | 471.8 | 338.1 | 523.4 | 375.4 | 640.1 | 410.2 | 741.5 | 465.3 |
Condenser Water Pressure drop( Kpa) | 80 | 85 | 87 | 90 | 94 | 96 | 100 | 105 | 110 | 115 | 118 | 125 |
Evaporator | Flooded Type |
Water Side max Pressure(MPa) | 1 |
Dia.of pipe to Evaporator(inch) | 5″ | 6″ | 6″ | 8″ | 8″ | 8″ | 10″ | 10″ | 10″ | 10″ | 10″ | 12″ |
Chilled Water Flow(m³/h) | 136.5 | 109.7 | 168.5 | 118.7 | 185.7 | 135.2 | 209.1 | 164.7 | 255.2 | 188.1 | 293 | 213.9 | 332.9 | 242.8 | 375.6 | 262.1 | 405.8 | 290.3 | 450.6 | 322.6 | 549.6 | 352.2 | 637 | 399.7 |
Evaporator Water Pressure drop(KPa) | 84 | 89 | 92 | 95 | 99 | 105 | 107 | 110 | 115 | 120 | 125 | 135 |
Running noise Db(A) | 70 | 65 | 71 | 66 | 73 | 67 | 75 | 70 | 77 | 72 | 79 | 74 | 79 | 74 | 80 | 75 | 77 | 72 | 79 | 74 | 79 | 74 | 80 | 75 |
Total Weight(kg) | 4200 | 4050 | 4900 | 4720 | 5520 | 5280 | 6230 | 6040 | 6780 | 6580 | 7200 | 7030 | 8060 | 7920 | 8850 | 8640 | 9320 | 9230 | 9910 | 9850 | 10800 | 10200 | 11500 | 11100 |
Running Weight(kg) | 5040 | 4860 | 5880 | 5660 | 6620 | 6340 | 7480 | 7250 | 8140 | 7900 | 8640 | 8440 | 9670 | 9500 | 10620 | 10370 | 11180 | 11080 | 11890 | 11820 | 12960 | 12240 | 13800 | 13320 |
Note:
1. Nominal cooling capacity based on: Evaporator inlet and outlet water temperature 12ºC/7ºC, Condenser inlet and outlet water temperature 30ºC/35ºC, Fouling coefficient 0.088m2.ºC/KW;
2. Chilled water temperature range: 5ºC ~ 15 ° C; R134a: 5ºC ~20ºC;
3. Cooling water temperature range: 15ºC ~ 40 ° C; R134a: 20ºC ~ 45ºC;
4. Specifications and dimensions will be subject to change without notice.About SANHER SANHE Freezing Machinery (Guangzhou)Co., Ltd. is a joint venture which was established by domestic Huizhuo and Japan Ronghe corporation with a total investment of 50 million Yuan in 2017. It located in Guangzhou Economic and Technological Development Zone . Combined with Japan R&D center and Guangdong University of Technology, We are committed to industrial chiller, central air conditioner, magnetic centrifugal chiller R&D and manufacture.
Our Main Product:1) Magnetic Bearing Centrigufal Chiller
2) Water cooled Screw Chiller, Air cooled screw Chiller, Flooded type Screw Chiller ,Evaporative Cooled Screw Chiller
3) Water cooled Scroll Chiller, Air cooled Scroll Chiller
4) Water-cooled Packaged air conditioner, Air-cooled Packaged air conditioner , clean constant temperature and humidity air conditioner, Precision air conditioning
5) Low temperature chiller(0ºC to -50ºC)
6) Anti-corrosion Chiller , Explosion-proof Chiller, etc. FACTORY SHOW
Testing Line
We have our own laboratories and prefessional testing Line. All SANHER chillers are factory tested under load conditions to ensure easy installation for users.
Cases
PACKAGEPlastic film + wooden frame/wooden boxFAQ
Q1: Are you a manufacturer?
A1: Yes, we have more than 10 years in water chiller business. New plant was bulit in 2017 in Guangzhou Economic&Technological Development Zone. Welcome to visit us anytime!
Q2: Could you help us to recommend the model for our project?
A2: Yes, we have engineer to check the details and make the scheme for you. Based on the following:1)Cooling capacity;2) Refrigerant;3) Ambient temperature;4)Voltage;5) For what industry6)The building drawing(if you have)7)Any other special requirements. Q3: How to ensure your product with good quality?
A3: We use the well-know brand accessories, such as Hanbell , copeland, danfoss compressor, Emerson expansion Valve, Siemens controller. All SANHER chillers are factory tested under load conditions to ensure good quality and easy installation for users.
Q4: What's the warrenty?
A4: 1 year warrenty for free if confirmed by both side damage in the quality reason. Q5: Whats your payment term?
A5: We accept TT, LC, Western Union, etc. Normally ,30% deposit for production, 70% balance before shipment.
Q6: How can I place an order?
A6: Contact us via made in China or contact below information.
Ms.Livia
Tel:0086 20 31600228-820
Mobile:0086 13590226431