China Online Module UPS Three Phase Pure Sine Wave 40kVA Low Frequency Module UPS, Find details about China Low Frequency Online UPS, UPS with Inverter Charger from Online Module UPS Three Phase Pure Sine Wave 40kVA Low Frequency Module UPS
MODEL | TC10K | TC15K | TC20K | TC30K | TC40K | TC60K | TC80K | TC100K | TC120K | |
Capacity | 10KVA | 15KVA | 20KVA | 30KVA | 40KVA | 60KVA | 80KVA | 100KVA | 120KVA | |
Power | 8KW | 12KW | 16KW | 24KW | 32KW | 48KW | 64KW | 80KW | 96KW | |
Power Factor | 0.8 | |||||||||
Input | Phase | 3 phase 4 wire and ground | ||||||||
Voltage Range | 380V±20%(3 phase), phase voltage 220V | |||||||||
Frequency Range | 45 - 65Hz | |||||||||
Rectifier | 3 phase 6 pulses, 12 pulses is optional | |||||||||
Output | Phase | 3 phase 4 wire and ground | ||||||||
Wave form | Pure sine wave | |||||||||
Crest Factor | 3:01 | |||||||||
Rated voltage | 380/400/415Voptiona+ -1% for static load, 5% forfluctuant load | |||||||||
Phase voltage setting | 200 - 244VAC, pls confirm when order | |||||||||
Transient response | +/-5%, 10ms | |||||||||
Frequency | 50 / 60 Hz + / - 0.05% | |||||||||
Total harmonic distortion | < 3%(linear load, < 5%( nonlinear load) | |||||||||
Short circuit current | Short current for 0.1s (200% current) | |||||||||
Overload capacity | Overload 125% for 10 Mins, 125%-150% for 1min .automatically resume when load become normal | |||||||||
Battery | Battery | Maintenance free lead-acid cell | ||||||||
DC Voltage | 384VDC | 396VDC | ||||||||
Max Charge Current | 6-30A adjustable | |||||||||
Bypass | Type | Static state + manual maintenance bypass | ||||||||
Input Phase | 3 phase 4 wire and ground | |||||||||
Input voltage range | 15% - 25% (the front control panel selectable) | |||||||||
Transfer time | Inverter / bypass transfer switch time(Overload): 0ms inverter / bypass transfer switch time (fault inverter) 1ms | |||||||||
Efficiency | Whole unit | >80% | ||||||||
Inverter | 91 | 91 | 92 | 92 | 93 | 93 | 95 | 95 | 95 | |
Remote signaling | Dry contact (battery low, battery discharging, bypass/ fault); output 12Vdc/80mA,Optional parts | |||||||||
Communication interface | RS232 ( SNMP , modem optional ) | |||||||||
Running temperature | 0-40 degree Celsius | |||||||||
Relative Humidity | Less than 95% (without condensing) | |||||||||
Noise at 1 M | less than 60 dB | |||||||||
Degree of protection | IP20 | |||||||||
Applicable Standards | EN50091-1-EMC EN50091-2liv.A | |||||||||
Product size(mm) | 780*580*1170 | 1000*660*1450 | 1200*900*1820 | |||||||
product weight(Kg) | 180.00 | 280 | 380 | 440 | 520 | 670 | 690 | 790 | 790 | |
Package size(mm) | 945*745*1395 | 1135*810*1755 | 1450*1110*1880 | |||||||
Package weight(Kg) | 200.00 | 300 | 400 | 460 | 550 | 700 | 750 | 850 | 850 |