China 4mm2 Electrical Cable Solar DC Cable Solar PV Cable, Find details about China Solar PV Cable, Electrical Cable from 4mm2 Electrical Cable Solar DC Cable Solar PV Cable
4mm2 Electrical Cable Solar DC Cable solar pv cable
Product Description
1. Construction: Tinned cooper, XLPE insulation, XLPE outer sheath.
2. Test Voltage: 6500V, 5min; rated voltage:1000/1800V DC.
3. Halogen free and low smoke, Rohs standard.
4. UV resistance.
5. Temperature rating:-40°C to 125°C, cold resistance.
6. UL and TUV certification, TUV2Pfg1169-1.
7. Power cable for photovoltaic system.
solar cable specifications
Core Conductor: | Tinned annealed copper(stranded core) |
Popular Sizes: | 1x2.5mm2,1x4mm²,1x6mm²,1x10 mm² , 2x2.5mm2,2x4mm²,2x6mm²,2x10 mm² |
Cable Conductor: | Stranded tinned annealed copper |
Insulation: | Electron-beam cross-linked Polyolefin(XLPE) |
Jacket: | XLPE(black, red) |
Nominal Volvatage: | Uo/U= 600/1000VAC, 1000/1800VDC |
Test Voltage: | 6500V, 50HZ, 5Min |
Tmperature Rating: | -45ºC upto +125ºC, -40ºF upto +257ºF |
Ambient Temperature: | 25 years( -40ºC upto +90ºC, -40ºF upto +194ºF) |
Max Short Circuit T: | 280ºC,+536ºF |
Fire Performance: | IEC 60332-1, UL1581 VW-1 |
Approval: | TUV Rheinland 2PfG 1169 1.5mm² to 50mm², UL. |
Bending Radius | Fixed installation>4X,Occasionally moved>5X |
Single-Core Cable
Type | Cross section | Strand design | Conductor diameter | Conductor diameter | Outer diameter | Rated voltage | Rated current |
mm² | No.x ø (mm) | mm | Ω /km | mm | VAC/DC | A | |
PV-1*1.5 mm² | 1.5 | 30x ø 0.25 | 1.6 | 13.9 | 4.5 | 1000/1800 | 20 |
PV-1*2.5 mm² | 2.5 | 48x ø 0.25 | 2.0 | 8.06 | 5.3 | 1000/1800 | 30 |
PV-1*4.0 mm² | 4.0 | 56x ø 0.3 | 2.6 | 4.97 | 6.2 | 1000/1800 | 50 |
PV-1*6.0 mm² | 6.0 | 81x ø 0.3 | 3.3 | 3.52 | 7.2 | 1000/1800 | 70 |
PV-1*10.0 mm² | 10.0 | 200x ø 0.25 | 4.4 | 2.12 | 8.3 | 1000/1800 | 95 |
PV-1*16 mm² | 16.0 | 224x ø 0.3 | 5.2 | 1.95 | 9.5 | 1000/1800 | 140 |
Dual-Core Cable
Type | Cross section | Strand design | Conductor diameter | Conductor diameter | Outer diameter | Rated voltage | Rated current |
mm² | No.x ø (mm) | mm | Ω /km | mm | VAC/DC | A | |
PV-2*1.5 mm² | 1.5 | 30x ø 0.25 | 1.6 | 13.9 | 5.80*9.30 | 1000/1800 | 20 |
PV-2*2.5 mm² | 2.5 | 48x ø 0.25 | 2.0 | 8.06 | 6.20*9.90 | 1000/1800 | 30 |
PV-2*4.0 mm² | 4.0 | 56x ø 0.3 | 2.6 | 4.97 | 6.90*11.30 | 1000/1800 | 50 |
Product Advantages
1.Electron-beam cross-linked compounds
2.UV, ozone and hydrolysis resistant
3.High temperature resistant, the materials do not melt or flow
4.Good cold flexibility
5.Very long service life > 25 years at 90°C
6.Compatible to all popular connectors
Technique Specification
Nominal Voltage: | Uo /U= 600/1000V AC , 1000/1800V DC |
Test Voltage : | 6500V , 50HZ , 5Min. |
Temperature Rating:
| -45ºC up to +125ºC -40ºF up to +257ºF |
Ambient temperature: | 25 years (TUV) -40ºC up to +90ºC -40ºF up to +194ºF |
Max. Short circuit temperature: | 280ºC,+536ºF |
Bending Radius:
| Fixed installation>4X Occasionally moved>5X |
Material Properties /Standards
Fire performance: | IEC 60332-1 |
Smoke emission: | IEC 61034 ;EN 50268-2 |
Low fire load: | DIN 51900 |
Approvals: | TUV 2PfG 1169/08.2007 PV1-F, UL4703 PV WIRE; UL854 USE-2 |
Application standards: | UNE 211 23;UNE 20.460-5-52,UTE C 32-502 NEC 2008/UL PV WIRE, USE-2 |