Networking Application and on-Line Type UPS Backup

China Networking Application and on-Line Type UPS Backup, Find details about China UPS, Power Supply from Networking Application and on-Line Type UPS Backup

Model NO.
Networking Application and On-line Type ups backup
Standby UPS
Sine Wave Output UPS
Output Capacity
Medium Type
Equipment Mode
Decentralized
Brand
Ttn
True Double-Conversion
Online UPS
Wide Input Voltage Range
110-300 VAC
Input Power Factor Correction
0.99
Output Power Factor
0.8
Frequency Converter Mode
50Hz/60Hz
Programmable Power
Management Outlets
Emergency Power off Function (Epo)
Yes
Eco Mode Operation for Energy Saving (Ec
Yes
Snmp+USB+RS-232 Multiple Communications
Yes
Hot-Swappable Battery Design
1-3k
Trademark
TTN
Specification
CE ISO: 9001
Origin
Zhejiang China
Model NO.
Networking Application and On-line Type ups backup
Standby UPS
Sine Wave Output UPS
Output Capacity
Medium Type
Equipment Mode
Decentralized
Brand
Ttn
True Double-Conversion
Online UPS
Wide Input Voltage Range
110-300 VAC
Input Power Factor Correction
0.99
Output Power Factor
0.8
Frequency Converter Mode
50Hz/60Hz
Programmable Power
Management Outlets
Emergency Power off Function (Epo)
Yes
Eco Mode Operation for Energy Saving (Ec
Yes
Snmp+USB+RS-232 Multiple Communications
Yes
Hot-Swappable Battery Design
1-3k
Trademark
TTN
Specification
CE ISO: 9001
Origin
Zhejiang China
Main Features
True double-conversion online UPS
Wide input voltage range (110-300 VAC)
Input power factor correction 0.99
Output power factor 0.8
50Hz/60Hz frequency converter mode
Programmable power management outlets
Emergency power off function (EPO)
ECO mode operation for energy saving (ECO)
SNMP+USB+RS-232 multiple communications
Smart battery charger design for optimized battery performance
Selectable output voltage via LCD panel
Optional isolation transformer offers full isolation and complete common mode noise rejection
Hot-swappable battery design (only available for 1-3K)

odel RM RM RM RMRM         6KR (L)RM        10KR (L)
1K (L)1.5K (L)2K (L)-3K (L)
PHASESingle phase with ground
CAPACITY1000 VA / 800 W1500 VA / 1200W2000 VA / 1600 W3000 VA / 2400 W6000 VA / 4800 W10000 VA / 8000 VA
INPUT
Nominal Voltage100/110/115/120/127 VAC or 200/208/220/230/240VAC208/220/230/240 VAC
Voltage Range55-150 VAC ± 5 % or 110-300 VAC ± 5 % at 50% load110-300 VAC at 50% load
80-150 VAC ± 5 % or 160-300 VAC ± 5 % at 100% load176-300 VAC at 100% load
Frequency Range45Hz ~ 55 Hz or 56Hz ~ 65 Hz46~54 Hz or 56~64 Hz
Power Factor>= 0.99 @ Nominal Voltage (100% Load)>= 0.99 @ 100% load
OUTPUT
Output Voltage100/110/115/120/127 VAC or 200/208/220/230/240VAC208/220/230/240 VAC
AC Voltage Regulation (Batt. Mode)± 1%± 1%
Frequency Range (Synchronized Range)40 Hz ~ 70 Hz46~54 Hz or 56~64 Hz
Frequency Range (Batt. Mode)50 Hz ± 0.2 Hz or 60Hz ± 0.2 Hz50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Current Crest Ratio3:013:01
Harmonic Distortion<= 3 % THD (Linear Load),<= 3 % THD (Linear Load),
<= 6 % THD (Non-Linear load)<= 6 % THD (Non-linear Load)
Transfer TimeAC Mode to Batt. ModeZero
Inverter to Bypass4 ms (Typical)Zero
Waveform (Batt. Mode)Pure Sinewave
EFFICIENCY
AC Mode86%87%87%88%89%
Battery Mode84%85%85%86%88%
BATTERY
Standard ModelBattery Type12 V / 9 Ah12 V / 7 Ah12 V / 9 Ah12 V / 9 Ah12 V / 7 Ah12 V / 9 Ah12 V / 7 Ah12 V / 9 Ah
Numbers23*346*62020
Typical Recharge Time4 hours recover to 90% capacity3 hours recover to 90% capacity4 hours recover to 90% capacity
Charging Current (Max.)1.0 A2.0 A
Charging Voltage27.4 VDC ± 1%41.1 VDC41.1 VDC ± 1%54.8 VDC82.1 VDC82.1 VDC ±1%273.0 VDC ±1%
± 1%± 1%± 1%
Long-run ModelBattery TypeDepending on the capacity of external batteriesDepending on applications
Numbers18-20
Charging Current (Max.)8.0 A2.0 A
Charging Voltage27.4 VDC ± 1%41.1 VDC41.1 VDC ± 1%54.8 VDC82.1 VDC82.1 VDC ±1%273.0 VDC ±1%
± 1%± 1%± 1%
INDICATORS
LCD DisplayUPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions
ALARM
Battery ModeSounding every 4 seconds
Low BatterySounding every second
OverloadSounding twice every second
FaultContinuously sounding
PHYSICAL
Standard ModelDimension, DxWxH (mm)380 x 438 x 88 [2U]480 x 438 x 88 [2U]480 x 438 x 88 [2U]480 x 438 x 88 [2U]600 x 438 x 88 [2U]600 x 438 x 88 [2U]UPS Unit : UPS Unit: 
580 x 438 x133 [3U]668 x 438 x 133 [3U]
Battery Pack :Battery Pack :
580 x 438 x 133 [3U]580 x438 x 133 [3U]
Net Weight (kgs)13.218.418.520.625.729UPS Unit : 17UPS Unit : 20
Battery Pack : 57Battery Pack : 63
Long-run ModelDimension, DxWxH (mm)380 x 438 x480 x 438 x480 x 438 x 88 [2U]480 x 438 x600 x 438 x600 x 438 x 88 [2U]580 x 438 x 133 [3U]668 x 438 x 133 [3U]
88 [2U]88 [2U]88 [2U]88 [2U
Net Weight (kgs)9.111.310.711.314.614.81720
ENVIRONMENT
Humidity20-90 % RH @ 0- 40°C (Non-condensing)
Noise LevelLess than 50dB @ 1 MeterLess than 55dBA @ 1 MeterLess than 58dBA @ 1 Meter