400V Power Frequency Earth Impedance Tester

China 400V Power Frequency Earth Impedance Tester, Find details about China Earth Resistance Tester, Insulation Resistance Tester from 400V Power Frequency Earth Impedance Tester

Model NO.
GDRK-5A
Control
Manual Control
Weight
0-100Kg
Power Source
AC220V
Measurement Range of The Impedance
0-200ohm
Resolution
0.001ohm
Measurement Error
± (Reading ×1%+0.002ohm)
Waveform of Test Current
Sine Wave
Frequency of Test Current
45Hz and 55Hz
Maximum Output Current
5A
Maximum Output Voltage
200V
Power Supply
AC220V±10%, 50Hz
Trademark
HV Hipot
Transport Package
Wooden Case
Specification
ISO, SGS
Origin
Wuhan China
HS Code
9030332000
Model NO.
GDRK-5A
Control
Manual Control
Weight
0-100Kg
Power Source
AC220V
Measurement Range of The Impedance
0-200ohm
Resolution
0.001ohm
Measurement Error
± (Reading ×1%+0.002ohm)
Waveform of Test Current
Sine Wave
Frequency of Test Current
45Hz and 55Hz
Maximum Output Current
5A
Maximum Output Voltage
200V
Power Supply
AC220V±10%, 50Hz
Trademark
HV Hipot
Transport Package
Wooden Case
Specification
ISO, SGS
Origin
Wuhan China
HS Code
9030332000
General information
 
GDRK-5A is applicable for testing power frequency characteristic parameters such as the power frequency earth impedance, contact voltage, step voltage, transfer potential and electric potential gradient of the site ground surface etc.; and the soil resistivity of all kinds of earthing devices. 
 
With the technique of anti-interference, this instrument can accurately obtain data under 50Hz power frequency in strong interference environment. The test current is relatively low (maximum 5A) and will not cause the over-potential of earthing devices during the testing. Meanwhile, as the tester has strong anti-interference ability, so that the measurement can be done with power. 



Features
 
1.The measured power frequency has fine equivalency. And the waveform of test current is sine wave. Difference between the test frequency and power frequency is only 5Hz. Measurement shall be done by adopting 45Hz and 55Hz frequencies. 

2.The interference capacity of voltage to ground is much strong. This instrument measures by adopting the non-power frequency method. Combining with the modern technique of wave filtering by software and hardware, it has strong anti-interference ability. Tested data is stable and reliable. Error caused by 30V power interference voltage shall only be 0.002Ω.

3.High accuracy. It can be used to measure large scale ground grid with small earth impedance. 

4.It can measure all characteristic parameters of earthing devices stipulated by relevant standards. It can not only measure the ground impedance, but also the resistive and reactive components. 

5. Site interference can be measured, which is convenient to estimate measurement error. 

6. Disconnection alarm function, to avoid inaccurate measurement. 

7. Easy operation. Directly display measurement result on LCD screen.

8. 50 groups of measuring data can be saved, with mini printer.

9. No need to use high current cable.

10. Small size, easy to carry.
 


Technical Specifications
 
Measurement range of the impedance0-200Ω
Resolution0.001Ω
Measurement error± (reading ×1%+0.002Ω)
Interference capacity of voltage to ground: error caused by 30V power-interference voltage shall be no more than 0.002Ω (when the test current is no less than 3A).
Waveform of test currentsine wave
Frequency of test current45Hz and 55Hz
Maximum output current5A
Maximum output voltage200V
Requirement of measurement wiresectional area of copper core for the current wire ≥ 2.5mm2
sectional area of copper core for the voltage wire ≥ 1.0mm2
Power supplyAC220V±10%, 50Hz
Environment to usetemperature: -10ºC~40ºC
Relative humidity<90%
Overall dimension440×350×310
Weight of the instrument10.5kg

400V Power Frequency Earth Impedance Tester