China Lsk System Electric Control Cabinet Booster Pump Control Panel, Find details about China Electrical Control Cabinet, Control Cabinet from Lsk System Electric Control Cabinet Booster Pump Control Panel
fault phenomenon | failure cause | elimination methods |
The manual is normal Automatic transmission failure | 1.No power supply or one or two phase power supply is needed | Check all phases of power supply and restore power supply |
Water level is too low | Put water in the sink | |
The motor burned | Repair or replace the motor | |
1.Line is loose | Check wiring and tighten connectors | |
2.Frequency converter malfunction | Check the fault content, check the cause according to the frequency converter manual, and restart after reset.Or disconnect the inverter power supply for a few seconds, the inverter fault reset before starting. | |
3The frequency converter is damaged | Repair or replace | |
4.Pressure switch damage | Repair or replace | |
5The pressure transmitter is damaged | Repair or replace | |
6.Switch failure | Repair or replace | |
Pump non - suction pressure gauge pointer to beat violently | Insufficient water supply for perfusion, air leakage at the connection between pipeline and instrument | Check pipeline and bottom valve, refill water diversion. Tighten air leakage |
The pump consumes too much power | Too much flow, impeller wear | Check whether the pump shaft is bent, replace the impeller, close the outlet valve to reduce the flow |