2. Main Features and Advantages
3. Main Technical data:
ECG | GRAND7S |
Input | 3/5 wire ECG cable |
Lead section | I II III aVR, aVL, aVF, V |
Sensitivity ( gain) selection | x 1/4, x 1/2, x 1, x 2, x 4 and auto |
Sweep speed | 6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s |
Heart rate measuring range | 15-350bpm |
HR measuring accuracy | ±1bpm or ±1% (select the bigger data) |
HR delay time | ≤10s |
Time Constant | ≥0.3s (monitoring mode),≥3.2s (Diagnostic mode) |
Calibration | ±1mv |
NIBP | |
Test method | Oscillometer |
Typical measuring time | <30 seconds ( typical adult cuff) |
Philosophy | Adult, Pediatric and Neonate |
Measurement range | Systolic pressure, diastolic pressure, mean arterial pressure |
Systolic pressure | Adult: 40-275 mmHg Pediatric: 40-200 mmHg Neonatal: 40-135 mmHg |
Diastolic pressure | Adult: 10-210 mmHg Pediatric: 10-150 mmHg Neonatal: 10-95 mmHg |
Mean arterial pressure | Adult: 20-230 mmHg Pediatric: 20-165 mmHg Neonatal: 20-110 mmHg |
Measurement type | Systolic Diastolic Mean |
Measurement parameter | Automatic, Continuous measurement |
Measurement method | Manual, Auto, STAT |
Automatic measuring intervals | 1-480min |
SPO2 | |
Display Type | Waveform, Data |
Measurement range | 0-100% |
SPO2 measuring accuracy | 2% for range from 70% to 100% |
Low perfusion performance | As low as 0.4% |
Pulse rate range | 0-250bpm |
Accuracy | ±1bpm or ±2% (select the bigger data) |
Resolution | 1bpm |
2-Temperature (Rectal & Surface) | |
Number of channels | 2 channels |
Measurement range | 21-50ºC |
Accuracy | ±0.2ºC from 21-50ºC |
Display | T1, T2, T |
Unit | ºC/ºF selection |
Refresh cycle | 1s-2s |
Respiration (Impedance & Nasal Tube) | |
Measurement type | 0-120rpm |
Accuracy | ±1bm or ±5%, select the bigger data |
Resolution | 1rpm |
EtCO2 (Optional ) | |
Technique | Infrared optical method |
Sampling mode | Sidestream or mainstream |
Measurement range | 0-150 mmHg ±10%/min (sidestream) |
Flow rate | 50ml/min |
Measuring accuracy | 0-40 mmHg, ±2mmHg 41-70 mmHg, ±5% of reading 71-100 mmHg, ±8% of reading 101-150 mmHg, ±8% of reading |
Others | |
Power supply | 100-240Vac, 50/60hz |
Built-in battery | 4400mAh Lithium battery |
Display | 12.1 inch TFT display |
Alarming mode | Audible-visual alarm |
Networking port | Ethernet port |
FAQ:
Q: Are you manufacturer ?
A: Yes, we are factory. we have our own R&D team and sales team,We provide you one-stop service.
Q: Do you have CE,ISO13485?
A: Yes,our products are approved by CE,ISO13485
Q: Is OEM &ODM available in your factory ?
A: Yes, you just offer us necessary documents and then we will produce the products as your requirements.
Q: What is your Payment term?
A: 1.L/C at sight;
2.T/T:30% deposit by T/T,70%balance by T/T before shipment
3.Trade term:EXW, FOBShanghai or CIF&CFR
Q: What is your Packing details?
A: 1.Wooden case or carton package,standard export packages
2.All of the productions are inspected carfully by QC before delivery.
Q: What is your Delivery time?
A: Usually, we make merchandise inventory, if we have the products in stock,The delivery time is5-10 days after receiving the deposit;
If we don't have the products in stock, we will arrange the production right now, the delivery time will be 20-30days,It depends on the quantity of order
Q: What is your Min.order?
A: There's no minimum quantity