12V 7ah VRLA Sealed Lead Acid Maintenance Free Ups Battery
Voltage:12V
Capacity:7AH
Size:151x65x100mm
Weight:2.04kg
Terminal :F1MODEL | VOLTAGE | CAPACITY | SIZE | WEIGHT | TERMINAL |
TL7-12 | 12V | 7AH | 151X65X100MM | 2.04 | F1 |
Valve Regulated Lead Acid batteries are designed with AGM technology, high performance plates and electrolyte to gain extra power output for common power backup system applications widely used in the fields of UPS, Emergency Lighting System.
Features
- Sealed and maintenance free operation
- Non-Spillable construction design.
- ABS Containers and Covers (UL94HB), UL94V-0 optional.
- Safety valve installation for explosion proof.
- High quality and high reliability.
- Exceptional deep discharge recovery performance.
- Low self discharge characteristic.
- Flexibility design for multiple install positions.
Advanstage
1.100% testing before out of factory, stable and reliable quality is guaranteed.
2.Professional alloy formula and advanced manufacturing techniques.
3.Completely sealed and maintainance free, low self-discharge.
4.Good charge-discharge acceptability.
5.Cyclic application: deep cycle charge-dischrge for more than 300 times.
6.Floating application: for 3-5 years.
Construction
· Component ......Raw material ·
Sealant ........Epoxy Resin
· Positive ........Lead dioxide ·
Safety valve .....EPDR
· Negative ........Lead ·
Terminal ........Copper
· Container ........ABS ·
Separator ........Fiber glass
· Cover ........ABS ·
Electrolyte .......Sulfuric acid
Application
Anti-theft system
Medical facilities
Radio transceiver
UPS for banking system
Power system
Computer backup power
Railroad engine and railway communication
Emergency lighting and lamps
Marine system
Electric tools
UPS for fire fighting system
Electronic instruments and other backup power Toys
Safety Notice for Using
Factory Tour/Quality Test
We have very advanced technology, special craft and precision testing equipments continuously supply our customer best quality battery and best service feeling.
Packaging & Delivery
Packaging Details:
1.All the battery with crown carton box or colorful carton box packing ,all box with wooden pallets packing.
2.The pallet size is 1.0mx1.2m fumigation certified hard wooden pallet and wraped with shrink plastic,we can load 10 or 20 pallets depending on battery weights.
3.We can also use bulk package for battery specially needed but with shrink plastic pack outside.
4:Delivery within about 15-30days as per the order quantity and specification requirement.
VALVE REGULATED LEAD ACID SEALD MF BATTERY MODELS/ADVANSTAGEWe have our own professional VRLA battery factory, so we can produce plates by ourselves, so that we can have a good control on the cost and the prodcution time and also we have full rage battery supply ability for sealed VRLA BATTERY.
Battery Use1.Batteries are delivered fully charged. During the storage before installation, the capacity of battery will decrease in different degrees. If the storage time is longer, battery should be recharged. If the storage time is less than 6 months, batteries should be recharged in constant voltage limit current 2.27V/Cell, the maximum current should be less than 0.25 C A, charging time 48~72h.2.Batteries could be in standby use and cycle use. Please charge the battery in constant voltage and limit current, the maximum current : 0.1C10~0.25 C10 A, battery standby use:25ºC 2V series: 2.25V/Cell, 6V or 12V series: 2.27V/Cell; battery cycle use: 25ºC, 2V series: 2.35V/Cell, 6V or 12V series: 2.40V/Cell.3.If the ambient temperature is too high or too low, in case the ambient temperature exceeds 20ºC~30ºC, then the charging voltage should be adjusted, in case of higher temperature, decreases the charging voltage, and in lower temperature increases the charging voltage, the correction factor : 4mV/ºC. Besides, that ambient temperature of battery is too high or too low will also influence the capacity and the service life.4.Battery should be recharged after the installation or after the discharging, charging the battery in constant voltage limit current mode, charging voltage: 25ºC 2.35V/Cell, the maximum current: 0.1C10~0.25C10 A, if discharging in 100% capacity, the charging time is about 24h-27h, if the charging current decreases to a very low current, and retain for 3h almost invariant or the charging electric quantity is 1.15 times of the discharging electric quantity, then consider the battery have been fully charged.5.Battery equalization charging: while the float voltage of the certain battery or some of the batteries is under 2.2V/Cell, then the whole pack of batteries should be equalization recharged, 25ºC 2.35V/Cell, the maximum current: 0.1C10~0.15 C10 A, time: 8h~12h.Requirements of Installation and Use1.Generally, battery are used in series connection, if batteries must be used in parallel connection, then the parallels should not be over two branches.2.Batteries can work in an ambient temperature of -25ºC~45ºC. The proper using temperature is 15ºC~30ºC, the battery room should have necessary ventilation.3.Batteries should be away from source of heat and spark, the security distance should be longer than 1 meter. Batteries should be stored away from direct sunlight, other rays,organic solvent gases and corrosive gases. To improve shockproof capability, the battery rack should be reinforced with foundation bolts.4.Batteries are delivered fully charged, so during the transportation and installation, batteries should be prevented from short circuit, be careful of the short circuit caused by batteries and metal parts of battery metal shelf or metal box touches.5.When installing the battery wires, the operator should use insulating tools and wear insulating gloves, also remove personal metal articles like watch, bracelets and so on.6.The operator should screw the bolt tightly during the connection, the proper torque should be 5~7N.M in case of battery overheating or battery striking fire caused by loose connection.7.Batteries of different models or different capacity cannot be mixed in use. When installing terminal connecting pieces, operators should carefully inspect if the polarity connecting is correct. The positive pole of battery connects with the positive pole of charging device, the negative pole of battery connects with the negative pole of charging device, be careful not to reverse the polarity.Requirements of Battery Working Maintenance1.During the battery working, the operator should take complete working records including battery voltage, current, ambient temperature and other relevant data and working time.2.Operators should inspect the fastening condition of connecting terminals such as battery overheating or striking fire caused by the connecting strip smudge or loose connecting.3.Inspecting the total float charging voltage, the operator should use voltmeter to measure the measurement number of battery positive and negative output end voltage is consistent with the indicating float charge voltage, and conforms to the required number of standard float charge voltage under the current temperature.4.During the battery working, if battery voltage is abnormal, appearance has damage like battery container and cover has flaw or deformation), battery electrolyte leaks, battery temperature is normal, the operator should find the failure cause in time.5.The appearance of battery should be cleared by clean water, organic solvent is not allowed. Be sure that battery use has a dry, clean, ventilated environment.
Notes for Battery Use
1.Don't separate or transform the battery.
2.Don't throw the battery into the water or the fire.
3.Please wear insulating gloves when connecting the battery packs.
4.Don't install, use or store batteries in which children can touch.
5.Don't use different brand, different capacity, different voltage and different degree of old and new batteries in series connection.
6.There is acid inside batteries, if battery is damaged by machine and acid splash the skin, clothes and even eyes, please wash with plenty of water or seek medical treatment immediately.
QUESTION YOU CONSERNED & ANSWER OF US
A : Africa, Middle east, Middle South America, South-east Asia ETC....
Q : Delivery is fast?
A : 15-30 work days for car battery, motorcycle battery and VRLA battery depending quantity and specification.
Q : Warrantee term and policy?
A: WARRANTY WILL START FROM THE DATE IT WILL ARIVE AT OUR PORT, AND IF ANY CLAIM OCCURS WITHIN THE WARRANTY PERIOD, WE WILL SEND YOU THE PICTURE OF THE BATTERY AND LOT NO, AND WE WILL ADJUST THAT AMOUNT FROM THE NEXT ORDER PAYMENT.
Q : What is your main advanstage?
A : 1. Super CCA Performance
2. Low self-discharge
3. Extended Battery Life
4. High Temperature Ressistant
5. Factory price
Q: What is your terms of payment?
A: T/T 30% as deposit, and 70% before delivery. Or Irrevocable LC sight from famous bank.
Q: How do you make our business long-term and good relationship?
A:1. Always good quality and competitive price to keep final customers's benefit ;
2. Treat customer as friend , sincerely do business and make friends with them.