6433f 4-Port Lightwave Component Analyzer (10MHz - 43.5GHz)

China 6433f 4-Port Lightwave Component Analyzer (10MHz

Model NO.
6433F
Warranty
3 Year Warranty
Power Source
AC 100-240V
Weight
〉10Kg
Installation
Direct Connected
Customized
Non-Customized
Trademark
Ceyear
Transport Package
Aluminum Transportation Case
Specification
W*H*D= 421mm*400mm*600mm
Origin
China
HS Code
9030849000
Model NO.
6433F
Warranty
3 Year Warranty
Power Source
AC 100-240V
Weight
〉10Kg
Installation
Direct Connected
Customized
Non-Customized
Trademark
Ceyear
Transport Package
Aluminum Transportation Case
Specification
W*H*D= 421mm*400mm*600mm
Origin
China
HS Code
9030849000

Product Overview:
Ceyear 6433 series Lightwave Component Analyzers includes 6433D (10MHz ~ 20GHz), 6433F (10MHz ~ 43.5GHz), 6433H (10MHz ~ 50GHz), 6433L (10MHz ~ 67GHz). The 6433 series is the latest solution to characteristic test of high-speed electro - optical (E/O) devices, optical - electro (O/E) devices, and optical - optical (O/O) devices. The modulation frequency range covers 10MHz~67GHz. It supports different frequency range, frequency interval, IF bandwidth setting. The minimum frequency resolution is up to 1Hz.
6433f 4-Port Lightwave Component Analyzer (10MHz - 43.5GHz)6433f 4-Port Lightwave Component Analyzer (10MHz - 43.5GHz)
Ceyear 6433 series LCA adopts an integrated design scheme that realizes a one-click fast broadband frequency sweep test based on broadband hardware optimization design, building network error model, and utilization of core calibration algorithm. It is mainly used for the test of bandwidth, amplitude-frequency response, phase-frequency response, group delay and other parameters of core electro - optical devices. (electro-optical modulator, direct modulated laser, light-transmitting components), electro-optical devices (PIN optoelectronic detector, APD optoelectronic detector, light-receiving components), optical - optical devices (passive devices such as fiber filter) in the modern high-speed light transmission system.
6433f 4-Port Lightwave Component Analyzer (10MHz - 43.5GHz)6433f 4-Port Lightwave Component Analyzer (10MHz - 43.5GHz)6433f 4-Port Lightwave Component Analyzer (10MHz - 43.5GHz)

Main Features:
  • Easy & quick calibration, and guided operation process
  • Integrated multi-functional operation interface
  • Large dynamic range, low noise of measurement path
  • Automatic user data removal that provides extended use for on-chip testing
  • Single -ended - balanced photoelectric device measurement
  • Multi-functional toolbox
  • Internal & external wavelength setting of light sources, and wider test range of communication wavelength
6433f 4-Port Lightwave Component Analyzer (10MHz - 43.5GHz)6433f 4-Port Lightwave Component Analyzer (10MHz - 43.5GHz)6433f 4-Port Lightwave Component Analyzer (10MHz - 43.5GHz)6433f 4-Port Lightwave Component Analyzer (10MHz - 43.5GHz)


Technical Specifications:
 

6433D Technical Specifications (10MHz - 20GHz)

 
Modulation Frequency Range10MH z ~ 20 GHz
Frequency Accuracy±1×10 -7
Frequency Resolution1 Hz
Working Wavelength1310±20nm, 1550±20nm
Average Output Optical Power Range-2 dBm~+4 dBm
Maximum Safe Average Input PowerInput 1: +7dBm / Input 2: +17dBm
Average Output Optical Power Accuracy±0.5 dB
Average Input Optical Power Measurement Range-35dBm~+5dBm (optical input 1) / -25dBm~+15dBm (optical input 2)
Average Input Optical Power Measurement Accuracy±0.5 dB
Relative Frequency Response Accuracy± 0.7 dB
Absolute Frequency Response Accuracy± 1.8 dB
Frequency Response Repeatability± 0.3 dB
Group Delay Measurement Accuracy± 13 ps
Phase Measurement Accuracy± 3.5 º
Maximum Weight56 kg
DimensionsWidth high depth = 421mm × 400mm × 600mm (excluding feet, hands)
Maximum Power Consumption600 W
 
6433F Technical Specifications (10MHz - 43.5GHz)

 
Modulation Frequency Range10MH z ~ 43.5 GHz
Frequency Accuracy±1×10 -7
Frequency Resolution1 Hz
Working Wavelength1310±20nm, 1550±20nm

Average Output Optical Power Range
-2dBm~+4dBm (1310nm)
-2dBm~+5dBm (1550nm)
Maximum Safe Average Input PowerInput 1: +7dBm / Input 2: +17dBm
Average Output Optical Power Accuracy±0.5 dB
Average Input Optical Power Measurement Range-35dBm~+5dBm (optical input 1) / -25dBm~+15dBm (optical input 2)
Average Input Optical Power Measurement Accuracy±0.5 dB
Relative Frequency Response Accuracy± 1.6 dB
Absolute Frequency Response Accuracy± 2.0 dB
Frequency Response Repeatability± 1.0 dB
Group Delay Measurement Accuracy± 18 ps
Phase Measurement Accuracy± 4.2 º
Maximum Weight60 kg
DimensionsWidth high depth = 421mm × 400mm × 600mm (excluding feet, hands)
Maximum Power Consumption600 W


6433H Technical Specifications (10MHz - 50GHz)
 
Modulation Frequency Range10MH z ~ 50 GHz
Frequency Accuracy±1×10 -7
Frequency Resolution1 Hz
Working Wavelength1310±20nm, 1550±20nm

Average Output Optical Power range
-2dBm~+4dBm (1310nm)
-2dBm~+5dBm (1550nm)
Maximum Safe Average Input PowerInput 1: +7dBm / Input 2: +17dBm
Average Output Optical Power Accuracy±0.5dB
Average Input Optical Power Measurement Range-35dBm~+5dBm (optical input 1) / -25dBm~+15dBm (optical input 2)
Minimum Measurable Frequency Response-60 dB
 
Average Input Optical Power Measurement Accuracy± 0.5 dB
Relative Frequency Response Accuracy± 1.6 dB
Absolute Frequency Response Accuracy± 2.5 dB
Frequency Response Repeatability± 1.7 dB
Group Delay Measurement Accuracy± 18 ps
Phase Measurement Accuracy± 4.2 º
Maximum Weight60 kg
DimensionsWidth high depth = 421mm × 400mm × 600mm (excluding feet, hands)
Maximum Power Consumption600 W



6433L Technical Specifications (10MHz - 67GHz)
 
Modulation Frequency Range10MH z ~67 GHz
Frequency Accuracy±1×10 -7
Frequency Resolution1 Hz
Working Wavelength1310±20nm, 1550±20nm

Average Output Optical Power Range
-2dBm~+4dBm (1310nm)
-2dBm~+5dBm (1550nm)
Maximum Safe Average Input PowerInput 1: +7dBm / Input 2: +17dBm
Average Output Optical Power Accuracy±0.5 dB
Average Input Optical Power Measurement Range-35dBm~+5dBm (optical input 1) / -25dBm~+15dBm (optical input 2)
Minimum Measurable Frequency Response-55 dB
Average Input Optical Power Measurement Accuracy± 0.5 dB
Relative Frequency Response Accuracy± 2.2 dB
Absolute Frequency Response Accuracy± 2.7 dB
Frequency Response Repeatability± 1.7dB
Group delay Measurement Accuracy± 31 ps
Phase Measurement Accuracy± 6.0 º
Maximum Weight63 kg
DimensionsWidth high depth = 421mm × 400mm × 600mm (excluding feet, hands)
Maximum Power Consumption600 W

Order Information

 
No.Model and NameDescription
16433D Lightwave Component Analyzer (dual port)Electric channel is 2 ports
26433D Lightwave Component Analyzer (four ports)Electric channel is 4 ports
36433F Lightwave Component Analyzer (dual port)Electric channel is 2 ports
46433F Lightwave Component Analyzer (four ports)Electric channel is 4 ports
56433H Lightwave Component Analyzer (dual port)Electric channel is 2 ports
66433H Lightwave Component Analyzer (four ports)Electric channel is 4 ports
76433L Lightwave Component Analyzer (dual port)Electric channel is 2 ports
86433L Lightwave Component Analyzer (four ports)Electric channel is 4 ports
 
  • Lists:
 
No.NameDescription
1Power Cord AssemblyStandard three-core power cord
2User Manual 
3Product Certification 
4Metrology Level of Fiber Jumper 
5RF Cable2 (corresponding interface: one female and one male)
6USB Cable 

FAQ
1. What is the relationship between China Electronics Technology Instruments Co., Ltd and  Ceyear Technologies Co., Ltd?
China Electronics Technology Instruments Co., Ltd is the former name of Ceyear Technologies Co., Ltd before Year 2021, but the brand of both are all Ceyear. SInce the beginning of 2021, as Ceyear is to be a listed company, the name was transformed from China Electronics Technology Instruments Co., Ltd to Ceyear Technologies Co., Ltd. Therefore, in previous product introductions and company catalog, sometimes you can still find the name of China Electronics Technology Instruments Co., Ltd

2. Is Ceyear a manufacturer or a trading company?
Ceyear is a manufacturer first, with R&D team (around 1500 engineer), production line (around 500 people), and domestic and overseas slaes team.
Thus Ceyear is a company integrating R&D, production and sales.


3. What products do you have?
T&M instruments, optical communication tools, microwave component, test systems, and other customized products.

4. How can I get local sevice?
Ceyear has worked with local distributors in different countries for many years, and could provide local after-sale services with the help of those local partners. If you already have some products of Ceyear(previously EI brand included) and looking for services, you can directly contact us through Made-in-China platform.