Technical Parameter | |
Rated Load | 10~40t |
Sensitivity | 2.0000±0.002mV/V |
Total Error | ±0.02%F.S |
Creep(30minutes) | ±0.02%F.S |
Recommended Excitation Voltage | 5V~18V(AC or DC) |
Maximum Excitation Voltage | 24V(AC or DC) |
Zero Balance | ±1%F.S |
Input Impedance | 380±10Ω |
Output Impedance | 350±5Ω |
Insulation Impedance | ≥5000MΩ |
Safe Overload | 150%F.S |
Ultimate Overload | 200%F.S |
Operating Temperature Range | (-30~+70)ºC |
Compensated Temperature Range | (-20~+60)ºC |
Temperature Effect On Load | ±0.02%F.S/10ºC |
Temperature Effect On Zero | ±0.02%F.S/10ºC |
Construction | Alloy Steel/Aluminum |
Protection Class | IP67&IP68 |
Citation | GB/T7551-2008/OIML R60 |
Mode of Connection | Input+E:Red Input-E:Black Output+S:Green Output-S:White |