China Microcomputer Digital Timer Switch Industrial Use Thc15A, Find details about China Timer, Thc15A from Microcomputer Digital Timer Switch Industrial Use Thc15A
Operating voltage: 220V/ 50-60hz
Control output: 16A (direct), also can expand capacity control use
Setting times: 16 groups of switches (day/week)
Set time: 1 minute to 168 hours
Travel time error: 1s/24h
Power failure memory: 60 days (built-in 1.2v rechargeable battery)
Size: same as dz47/2p, 80x56x36mm
Mounting method: 35MM guide rail
Application: advertising light boxes, street lamps, ovens, broadcasting equipment and other electrical appliances can be set up for one week at a time to work throughout the year
Application methods
1. Calibration of Beijing time
While pressing the "clock" button, press the "minutes", "hours" and "weeks" respectively to adjust the Beijing time.
2. Timing setting
A. Press the "timing" button, and the word "1 ON" will be displayed at the bottom left of the display screen (indicating the first opening time).Then press "minutes", "hours" and "days" respectively to enter the required opening time.
B. Press the "timing" button, and the word "1 OFF" will be displayed at the bottom left of the display screen (indicating the first closing time).Then press "minutes", "hours" and "days" respectively to enter the required closing time.
C. Continue to press the "timing" button, and the bottom left of the display screen will display (2 ON, 2 OFF...17 ON, 17 OFF) refer to steps A and B to set the switching time for each subsequent time.If you only need to set on and off once, you must press the "cancel/restore" button to cancel the time set after them.
D. Press the "set" button and then the "week" button to set the same or different cycle mode from day to day, from Monday to Friday, from Monday to Saturday, or from Saturday to Sunday.
Fault query:
1. If the setting time of the switch is not turned on, or the time to turn off is not related after the switch is turned on, check whether the "week" is correct, otherwise, please adjust it again.
2, if confirmed that "open" and "off" time set to completely correct, but the switch is opened in shouldn't open time, or time off, not closed, please check whether to eliminate redundant sets of switch time, if no, please refer to the method described in the "time setting" to eliminate (note: the switch time display "- : --" just said, do not think that "prefer" said eliminate)
3. If the above two are all correct and the switch is still not working properly, please check whether it is in the automatic position.
Matters needing attention:
1. In order to prevent electric shock and heat under strong current, the product is used for electric appliances and power supply to contact firmly.
2, the switch into the line can only be connected to the specified voltage power supply, do not connect to other power supply.Faulty wiring is not a quality problem (if you need special voltage, please order).
3. Please do not use this control switch for any equipment (such as medical equipment and large equipment) that may cause accidents related to human life or have a significant impact on the society due to the error of the time control switch
4. The switch shall be operated in a gas environment free from moisture, corrosion and heavy metal content, and shall not be contaminated with oil or water