3 Phase 400 kVA New Diesel Generator (GDC400*S)

China 3 Phase 400 kVA New Diesel Generator (GDC400*S), Find details about China Generator, Silent Generator from 3 Phase 400 kVA New Diesel Generator (GDC400*S)

Model NO.
GDC400*S
Conditions of Use
Land Use
Usage
Common Units
Landuse Type of Unit
Ordinary
Excitation Mode
AC Rotating Exciter
Wire
100% Pure Copper Wire
Alternator
Stamford, Marathon, Engga, Leroy Somer
Engine
Perkin Brand, Cummins, Mtu, Deutz Is Optional
Controller
Dse 7320, Smartgen Hgm6110, Hgm6120 Is Optional
Function
ATS/Amf, Open/Souldproof Is Optional
Test Load
25%, 50%, 75%, 100%, 110%
Voltage Range
110V-690V
Trademark
GODLIKE (OEM supported)
Transport Package
in Strong Plywood
Specification
IECBS 5000, IEC 34, CCC, CE, ISO9001, SGS
Origin
Jiangdu, Jiangsu, China
HS Code
8502131000
Model NO.
GDC400*S
Conditions of Use
Land Use
Usage
Common Units
Landuse Type of Unit
Ordinary
Excitation Mode
AC Rotating Exciter
Wire
100% Pure Copper Wire
Alternator
Stamford, Marathon, Engga, Leroy Somer
Engine
Perkin Brand, Cummins, Mtu, Deutz Is Optional
Controller
Dse 7320, Smartgen Hgm6110, Hgm6120 Is Optional
Function
ATS/Amf, Open/Souldproof Is Optional
Test Load
25%, 50%, 75%, 100%, 110%
Voltage Range
110V-690V
Trademark
GODLIKE (OEM supported)
Transport Package
in Strong Plywood
Specification
IECBS 5000, IEC 34, CCC, CE, ISO9001, SGS
Origin
Jiangdu, Jiangsu, China
HS Code
8502131000
3 Phase 400 kVA New Diesel Generator (GDC400*S)
1) Power range: 400kVA/320kw
2) Brushless Synchronous A. C. Alternator,

3) Stamford Type of Electric Generator,
4) Three Phase optional, IP23, Class H,
Scope of Supply:
1-Brand new engine and brushless AVR controlled alternator
2-Set mounted Smartgen Auto Controller
3-MCCB(Circuit Breaker), Emergency stop button, low oil pressure shutdown, high engine temperature shutdown.
4-Rubber Anti Vibration Mounts and skid basefram with 6-8hours integral fuel tank.
5-Genset equipped with battery charger and 24V high performance lead acid starting batteires and connecting with cables.
6-Genset equipped with industrial silencer and flexible exhaust hose.
7-Genset equipped with fan and closed circuit cooled radiator(40degree centigrade).
8-Genset with filtering systems including air filter, fuel filter & lub-oil filter.
9-Supply relative documents(testing report, diagram, operation/maintenance manual/spare parts manuals)for engine and alternator

Engine specification
 
2. Multi-cylinder in-line or veer engine, 4-stroke, direct injection
3. Naturally aspirated, turbocharged, water cooled or turbocharged with air intercooler
4. Machinery or electronic governing
5. Fuel injection pump
6. Electric motor starting system
7. Forged steel crankshaft, cast iron cylinder and replaceable wet type cylinder liner
8. Low discharge, and low fuel consumption

Alternator: Stamford
Option with: Marathon, Leroy somer,
A) three phase brushless generator, self-excited, 4-pole, single bearing
B) AVR self-regulated, voltage regulation rate ≤ ± 1%
C) IP23 protection grade
D) Class H insulation
E) Radio interference restraining accords with stipulation of VDE0875-N and ISO8528
F) Moistureproof, sand-proof, dustproof, salt-proof and vibration-proof

Control system:
1. Automatic cutter which is suitable for the generator power
2. Turn on key
3. A device to measure the generators speed
4. Counter for measuring the Operating hours
5. Device to measure the current overload with a switched current
6. A device to measure the battery voltage
7. Voltmeter with a voltage exchanger
8. A device to measure the frequency
9. Thermostat to regulate the voltage
10. A device to measure the oil pressure
11. Alerting lamps indicating low and high temperature
12. Controller of the current increase and short circuit
13. Emergency stop button

Warranty:
12 months or 1000 running hours from shipment date. If the quality problem arise during the warranty period, and verified the problem is caused by our genset-body instead of external or natural reasons. (Refer to all kinds of natural disaster, shipping, loading, unloading, wrong-operation, etc), we will supply the relevant spare parts free of charge for maintenance; After the warranty period, we can supply the required spare parts for you under cost prices
Our service quality assurance:
1)Before-sale Service: We provide detailed product technical parameters for equipment choosing and system designing
2)Service quality assurance: Our sale staffs are all experience and professional, who can provide the most proper system design and optimized equipment for the customers.
3)After sale maintenance service: We create files for end user and provide them follow-up service, regular return visit and permanent maintenance.
 
Generator Set Model CodeGDP400*S
AlternatorAlternator Model CodeHCI444F
Alternator BrandStamford
Frequency(Hz)50Hz
Rated Power(KW/KVA)320KW/400KVA
Standby Power(KW/KVA)352KW/440KVA
Rated Voltage(V)400/380V
Rated Current(A)72A
Steady Voltage Regulation≤ 1.0%
Transient Voltage Regulation≤ +20%, -15% (60% In, cosφ =0.4 lag)
Adjustable Voltage Range95-105% Un
Waveform Distortion at No-load≤ 5% (Line Voltage)
Insulation ClassH
Power Factor (cosφ )0.8
EngineEngine Model Code2506C-E15TAG2
Engine BrandPerkin
Speed(RPM)1500
Bore X Stroke (mm)102x120
Displacement (L)3.9
Max Water Temperature100C
100%Load Fuel Consumption (g/kw. h)209
Governor TypePerkin Unique Pump with Electrical Fuel Control System (EFC)
Exhaust Back Pressure10kPa (Maximum)
Lubrication Oil(L)11
Generator SetStart MethodElectric Start
Battery Voltage(V)24
Output3-Phase/4-Wire
Standard Altitude≤ 1300mm, if above, 4% of rated power will descend per 300 meter
Ambient Temperature≤ 40C, Well Ventilation, If above, 2% of rated power will descend per 11C
Silent type Size(MM)4300*1430*2175
Packing MaterialNude
Net Weight(kg)open type4306
ATS& AMF: module functions1. Low oil pressure shutdown.
2. High water temperature shutdown.
3. Over speed shut down.
4. Under voltage tripping.

CUMMINS configuration and technical data

50HZ, 3 Phase, 400/230V
No.GENSET
Model
OUTPUT POWER 
1500RPM 50HZ
Engine
Model
Alternator ModelCyl.Disp.Bore*StrokeFuel Cons.
Prime
KVA
Prime
KW
Standby
KVA
standby
KW
CUMMINSGODLIKESTAMFORD(nos)(L)(mm)(g/kw.h)
1GDC20201623184B3.9-G1/G2JDG164DPI 144D 43.9102*120215
2GDC25252028224B3.9-G1/G2JDG184FPI 144E 43.9102*120215
3GDC30302433264BT3.9-G1/G2JDG184GPI 144G 43.9102*120215
4GDC40403244354BT3.9-G1/G2JDG184HPI 144J 43.9102*120215
5GDC43433447374BTA3.9-G2JDG224CUCI224C43.9102*120215
6GDC50504055444BTA3.9-G2JDG224DUCI224D43.9102*120215
7GDC57574563504BTA3.9-G2JDG224ESUCI224E43.9102*120215
8GDC60604866534BTA3.9-G2JDG224EUCI224E43.9102*120215
9GDC63635069556BT5.9-G2JDG224EUCI224E65.9102*120215
10GDC73735880646BT5.9-G2JDG224FUCI224F65.9102*120215
11GDC88887096776BT5.9-G2JDG224GUCI224G65.9102*120215
12GDC939375103826BT5.9-G2JDG224HUCI274C65.9102*120215
13GDC10010080110886BT5.9-G1/G2JDG274CUCI274C65.9102*120215
14GDC120120961321066BTA5.9-G2JDG274DSUCI274D65.9102*120215
15GDC1351351081491196BTAA5.9-G2JDG274ES UCI274E65.9102*120215
16GDC1381381101511216CTA8.3-G2JDG274ES UCI274E68.3114*135210
17GDC1501501201651326CTA8.3-G2JDG274EUCI274E68.3114*135210
18GDC1601601281761416CTA8.3-G2JDG274FUCI274F68.3114*135210
19GDC1801801441981586CTA8.3-G2JDG274GUCI274G68.3114*135210
20GDC2002001602201766CTAA8.3-G2JDG274HUCI274H68.3114*135210
21GDC2252251802481986LTAA8.9-G2JDG274JUCD274J68.9114*135197
22GDC2502502002752206LTAA8.9-G2JDG274KUCD274K68.9114*135197
23GDC250250200275220NTA855-GAJDG274KUCD274K610.8125*147200
24GDC250250200275220MTA11-G2AJDG274KUCD274K610.8125*147200
25GDC275275220303242NTA855-G1AJDG314DSHCI444D610.8125*147188
26GDC300300240330264NTA855-G1BJDG314DHCI444D610.8125*147188
27GDC313313250344275NTA855-G1BJDG314ESSHCI444ES610.8125*147188
28GDC325325260358286NTA855-G1BJDG314ESHCI444ES614.0140*152200.2
29GDC350350280385308NTA855-G2AJDG314E HCI444E614.0140*152200.2
30GDC350350280385308NTA855-G4JDG314E HCI444E614.0140*152200.2
31GDC375375300413330NTAA855-G7JDG314FSHCI444FS614.0140*152205.4
32GDC375375300413330KTA19-G2JDG314FSHCI444FS614.0140*152205.4
33GDC400400320440352NTAA855-G7AJDG314FHCI444F614.0159*159205.4
34GDC420420336462370NTAA855-G7AJDG354CHCI544C618.9159*159200.7
35GDC450450360495396KTA19-G3JDG354CHCI544C618.9159*159200.7
36GDC500500400550440KTA19-G3AJDG354DHCI544D618.9159*159200.5
37GDC500500400550440KTA19-G4JDG354DHCI544D618.9159*159200.5
38GDC550550440605484KTAA19-G5JDG354ESHCI544D618.9159*159200.5
39GDC600600480660528KTAA19-G6JDG354EHCI544E618.9159*159208
40GDC600600480660528KTAA19-G8JDG354EHCI544E618.9159*159208
41GDC625625500688550KTAA19-G6AJDG354FSHCI544F-S618.9159*159202
42GDC625625500688550KT38-GJDG354FSHCI544F-S618.9159*159202
43GDC700700560770616KTA38-GAJDG354GHCI544F-S1237.8159*159213
44GDC750750600825660KTA38-G2JDG404B LVI634B1237.8159*159209
45GDC800800640880704KTA38-G2BJDG404C LVI634C1237.8159*159196
46GDC900900720990792KTA38-G2AJDG404D LVI634D1237.8159*159196
47GDC100010008001100880KTA38-G4JDG404E HCI 634G 1237.8159*159198
48GDC112511259001238990KTA38-G9JDG404FHCI 634G 1237.8159*159198
49GDC12501250100013751100KTA50-G3JDG404GHCI 634J 1237.8159*159213
50GDC13751375110015131210KTA50-G8HCI 634J HCI 634K 1237.8159*159213
51GDC15001500120016501320KTA50-GS8LVI 634G LVI 634G 1237.8159*159213
 