Handheld TFT Blood Flow Detector Vascular Doppler Monitor

China Handheld TFT Blood Flow Detector Vascular Doppler Monitor, Find details about China Automated Vascular Doppler, Abdominal Vascular Doppler from Handheld TFT Blood Flow Detector Vascular Doppler Monitor

Model NO.
VD-100D
Doppler Frequency
100--7000Hz
Temperature
5 Degree ~ +40 Degree
Trademark
Poweam
Transport Package
Carton
Specification
SGS, CE, ISO13485
Origin
China
HS Code
90181930
Model NO.
VD-100D
Doppler Frequency
100--7000Hz
Temperature
5 Degree ~ +40 Degree
Trademark
Poweam
Transport Package
Carton
Specification
SGS, CE, ISO13485
Origin
China
HS Code
90181930
Handheld TFT blood flow detector vascular doppler monitor

Features of handheld vascular doppler: 
VD-100D TFT LCD displays the wave of the instant blood flow average velocity and strength. It  prints the monitoring blood flow curve simultaneously;
Detect the blood stream status of arterialenous by 8MHz probe;
Detect the blood flow average velocity, detect the result of fingers/toes and part of body's vein anatomies o peration;
VD-100D portable bidirectional vascular Doppler with large color LCD screen;
Built-in ARM microprocessor & real-time displays blood flow velocity waveform;
Can store 50 detected waveforms;
High-speed USB/RS -232 port, can be connected directly to computer to analyze, store, and print the waveform data;

Specification of doppler vascular portable: 
Water-proof degree:Common device, without function of water-proof.
    Safety degree of flammable gas:  Unsuitable to use under the flammable gas.  
Working mode: continuous work
Frequency range:Main unit :200±80~5000±1000HZ Probe :350±80~2500±500HZ
External output:loudspeaker, single channel with earphone jack(optional) 
Emissive waveform: sine wave
Ultrasonic frequency:5.0MHz±10% ,8.0MHz ±10%
Ultrasonic frequency average intensity: < 50mW/cm2
Velocity measure range:0~100 cm /s. 
Overall sensitivity:> 100dB
Test error:≤20%(relative error)

Frequency mode display range:0.2 KHz~7.0 KHz
LCD Display:240*320dots TFT, LCD cursor indicates blood stream speed, double display mode for the spectrum and velocity.
Power supply: AC/DC. Input AC power: 110-240V  50Hz/60Hz  Output DC power: 24V/1.5A ;
Power consume:<20W;built-in Ni-MH rechargeable battery:14.4V/1600 mAh.
Fuse: for adapter:  3.15A, for rechargeable battery:1.75A,for charging circuit inside: 1.5A.
Power indication: blue LED indication 
Charge indication:the charge indicator is yellow when charging and become green after full charge.
Alarm indication: the indicator light is red when the lack of battery.
Lack of paper indication: When the recorder is lack of paper, the indication light is red. 
Environment condition: 
Humidity:<80%, 
Temperature:+5ºC ~ +40ºC , 

Atmospheric pressure:86kPa ~ 106kPa.
Transport and storage environment:
Temperature:-10ºC ~ +55ºC ,
Humidity:<80%,
Atmospheric pressure:86kPa ~ 106kPa


 
Name handheld vascular doppler
ModelVD-100D