AC/DC Breakdown & Insulation Resistance Tester/Testing Equipment With Compact Structure

China AC/DC Breakdown & Insulation Resistance Tester/Testing Equipment With Compact Structure, Find details about China Resistance tester, Insulation Resistance from AC/DC Breakdown & Insulation Resistance Tester/Testing Equipment With Compact Structure

Model NO.
GD9850A
Output waveform
Sine wave, 1.3<crest factor<1.5
Upper limit setting of leak current
Range: 0.01-12.00mA
DC withstand voltage test
Rated output: 6KV DC
Upper limit settin of DC leak current
range: 0.01-6.00mA
Slow rising time
Range: 0.1-999.9S
Test time
Range: 0.5-999.9S, 0 is continuous testing
Trademark
HV Hipot
Transport Package
Wooden Box
Specification
ISO, SGS
Origin
Wuhan China
HS Code
9030332000
Model NO.
GD9850A
Output waveform
Sine wave, 1.3<crest factor<1.5
Upper limit setting of leak current
Range: 0.01-12.00mA
DC withstand voltage test
Rated output: 6KV DC
Upper limit settin of DC leak current
range: 0.01-6.00mA
Slow rising time
Range: 0.1-999.9S
Test time
Range: 0.5-999.9S, 0 is continuous testing
Trademark
HV Hipot
Transport Package
Wooden Box
Specification
ISO, SGS
Origin
Wuhan China
HS Code
9030332000
Product Description

The AC Insulation Tester is electric safety device. It is neat and compact structure with mature technology. It is widely used for household appliance, instrument and components etc.



Features
  • It has the functions of pass/fail determine, alarm, testing time automatic control.
  • Easy operation, small size.
  • With high speed of over-current cut-off.

Specifications
 
Input Voltage: 110V or 220VAC, ±10%, single phase
Frequency: 47-63Hz
Fuse: 4A/250VAC
AC withstand testRated output: 5kV AC
Output frequency50Hz or 60Hz, for option
Output waveformSine wave, 1.3<crest factor<1.5
Upper limit setting of leak currentRange: 0.01-12.00mA
Resolution: 0.01mA
Accuracy: ±(2% of setting value+2digit)
Lower limit setting of leak currentRange: 0.00-12.00mA
Resolution: 0.01mA
Accuracy: ±(2% of setting value+2digit)
DC withstand voltage testRated output: 6KV DC
Upper limit setting of leak currentRange: 0.01-6.00mA
Resolution: 0.01mA
Accuracy: ±(2% of setting value+2digit)
Lower limit setting of leak currentRange: 0.00-6.00mA
Resolution: 0.01mA
Accuracy: ±(2% of setting value+2digit)
Voltage settingRange:  0-5000V AC
0-6000V DC
Resolution: 1V
Accuracy: ±(2% of setting value+5V)
Voltage stability±(1% of setting value+5V)
Slow rising timeRange: 0.1-999.9S
Resolution: 0.1S
Accuracy: ±(0.1% of setting value+0.05S)
Test timeRange: 0.5-999.9S, 0 is continuous testing
Resolution: 0.1S
Accuracy: ±(0.1% of setting value+0.05 S)
Arc detectionRange: class 1 to class 9 can be set, 0 is non-detection arc status
Voltage displayRange: 0-5.00KV AC
0-6.00KV DC
Resolution: 0.01KV
Accuracy: ±(3% of display value+3digit)
Current displayRange: 0.01-12.00mA AC
0.01-6.00mA DC
Resolution: 0.01mA
Accuracy: ±(2% of display value+3digit)
Insulation resistance testRated output: 1000V DC
Voltage settingRange: 500 - 1000V DC
Resolution: 100V
Accuracy: ±(2% of setting value+5V)
Voltage displayRange: 0.50KV - 1.00KV DC
Resolution: 0.01KV
Accuracy: ±2% of display value
Resistance displayRange: 1.000 - 2000MΩ
Accuracy: ±(5% of display value+3digit) (1-1000MΩ)
±(10% of display value+3digit)(1000-2000MΩ)
Upper limit setting of resistance0-2000MΩ, 0 is non determination
Lower limit setting of resistance1.0-999.9MΩ
Delay time of determinationRange: 0.8 - 999.9 S, 0 is continuous determination
Resolution: 0.1S
Accuracy: ±(0.1% of display value+0.05 S)
Dimension326x102x380mm
Weight9kg


AC/DC Breakdown & Insulation Resistance Tester/Testing Equipment With Compact Structure