China Zn63 Vs1 10kv 630A Vacuum Outdoor Circuit Breaker 11kv Vcb with Great Price, Find details about China Circuit Breaker, Vacuum Circuit Breaker from Zn63 Vs1 10kv 630A Vacuum Outdoor Circuit Breaker 11kv Vcb with Great Price
No | Item | Unit | Value | ||||
1 | Rated voltage | kV | 12 | ||||
2 | High test operating voltage | kV | 12 | ||||
3 | Rated current | A | 630 | 630 | 1250 | ||
4 | Rated short-circuit breaking current | kA | 20 | 25 | 31.5 | ||
5 | Rated short-circuit closing current | kA | 50 | 63 | 80 | ||
6 | Rated peak withstand current | kA | 50 | 63 | 80 | ||
7 | 4Srated short time withstand current | kA | 20 | 25 | 31.5 | ||
8 | Rated Insulation Level | P.F. withstand voltage(Before and after the rated breaking) | kV | 42(fracture48) | |||
Impulse withstand voltage(Before and after the rated breaking) | kV | 75(fracture84) | |||||
9 | Rated operating order | O-0.3S-CO-180S-CO | |||||
10 | Mechanical life | times | 3000 | ||||
11 | Rated short-circuit breaking current breaking times | times | 50 | ||||
12 | Actuator Rated closing voltage(DC) | V | 110,220 | ||||
13 | Actuator Rated opening voltage(DC) | V | 110,220 | ||||
14 | Clearance between open contacts | mm | 11±1 | ||||
15 | Supper Travel(Compressed length of contact springs) | mm | 3.5±0.5 | ||||
16 | Non corresponding time period between tri-phase opening and closing | ms | ≤2 | ||||
17 | Bounce time of closing contacts | ms | ≤2 | ||||
18 | Average time of opening | s | 0.9~0.12 | ||||
19 | Average time of closing | s | 0.4~0.8 | ||||
20 | Opening time | ms | 50 | ||||
21 | Closing time | ms | 100 | ||||
22 | Main loop resistance of each phase | μΩ | 60 | 50 | |||
23 | Allowed acumination thickness between moving contact and static contact | mm | 3 |
No | Item | Unit | Value | ||||||||
1 | Rated voltage | kV | 12/24 | ||||||||
2 | High test operating voltage | kV | 12/24 | ||||||||
3 | Rated current | A | 630,1000,1250 | 1600 | 2000,2500,3150 | 4000 | |||||
4 | Rated short-circuit breaking current | kA | 20 | 25 | 31.5 | ||||||
5 | Rated short-circuit closing current | kA | 50 | 63 | 80 | ||||||
6 | Rated peak withstand current | kA | 50 | 63 | 80 | 80 | 100 | 100 | 125 | ||
7 | Rated short time withstand current | kA | 20 | 25 | 31.5 | 31.5 | 40 | 40 | 50 | ||
8 | Rated Insulation Level | P.F. withstand voltage(Before and after the rated breaking) | kV | 42(fracture48) | |||||||
Impulse withstand voltage(Before and after the rated breaking) | kV | 75(fracture84) | |||||||||
9 | Rated operating order | O-0.3S-CO-180S-CO | |||||||||
10 | Mechanical life | times | 3000 | ||||||||
11 | Rated short-circuit breaking current breaking times | times | 50 | ||||||||
12 | Actuator Rated closing voltage(DC) | V | 110,220 | ||||||||
13 | Actuator Rated opening voltage(DC) | V | 110,220 | ||||||||
14 | Clearance between open contacts | mm | 11±1 | ||||||||
15 | Supper Travel(Compressed length of contact springs) | mm | 3.5±0.5 | ||||||||
16 | Non corresponding time period between tri-phase opening and closing | ms | ≤2 | ||||||||
17 | Bounce time of closing contacts | ms | ≤2 | ||||||||
18 | Average time of opening | s | 0.9~0.12 | ||||||||
19 | Average time of closing | s | 0.4~0.8 | ||||||||
20 | Opening time | ms | 50 | ||||||||
21 | Closing time | ms | 100 | ||||||||
22 | Main loop resistance of each phase | μΩ | 60 | 50 | |||||||
23 | Allowed acumination thickness between moving contact and static contact | mm | 3 |