( hrv ) 30 Kw Heat Exchanger Heat Recovery Air Conditioning Unit

China (hrv) 30 Kw Heat Exchanger Heat Recovery Air Conditioning Unit, Find details about China Air to Air Heat Exchanger (hrv) , Air to Air Heat Exchanger from (hrv) 30 Kw Heat Exchanger Heat Recovery Air Conditioning Unit

Model NO.
hax
Heating Capacity
9.5-180kw
Refrigerant
R22, R407, R410, Choose by Clients
Air Flow
1500-35000 CMH
Esp
80-500 PA
Motor Power
0.3-+15kw
Heating Exchange Efficiency
>87%
Weighit
310-1920kgs
Structure Material
Heat Pump Type
Core
Aluminum Heat Exchanger
Trademark
Headpower
Transport Package
Plastc+Foam+Woden Case
Specification
1unit/case
Origin
Guangdong Foshan
Model NO.
hax
Heating Capacity
9.5-180kw
Refrigerant
R22, R407, R410, Choose by Clients
Air Flow
1500-35000 CMH
Esp
80-500 PA
Motor Power
0.3-+15kw
Heating Exchange Efficiency
>87%
Weighit
310-1920kgs
Structure Material
Heat Pump Type
Core
Aluminum Heat Exchanger
Trademark
Headpower
Transport Package
Plastc+Foam+Woden Case
Specification
1unit/case
Origin
Guangdong Foshan
1)The Feature of (hrv) 30 kw heat exchanger heat recovery air conditioning unit
a.Hig-grad configuration, reliable running
Global famous fully-closed scroll compressor is used;external balance thermostiatic expansion valve,solenoid valve and other refrigerating parts of renowned brands are adopted.
b.Fully fresh air ,high air quality
Fresh air coming  from the outdoors can be directly treated by the unit, and polluted indoor air due to human activities and building materials can be exhausted;freshair ,exhaust air channel heat exchange not only meet air conditioning requirements,but also ensures the absolute fresh air,fundamentally prohibiting cross contamination of air,and ozone disinfection UV germicidal lamp and high static pressure dust removal device are also optional.
c.Independent fresh air refrigerating system
Compared to conventional chilled water systems,the evaporation temperature of the unit is 8-10ºC higher,and second heat exchange for the transfer of chilled water is not needed,enhancing refrigerating efficiency by at least 30%.
d.Cooling tower and outdoor unit not needed
Using pipe-piece evaporation condensation technology,make fulluse of fin surface evaporation of water film through the mass transfer and heat transfer can be realized within the refrigerant condenser cooling cold film,crew integration,structural design,no outdoor unit without the need for cooling towers and high-power cooling pumps,fans,pumps and engineering of distribution power.
e.Patented all heat recovery technology having heat recovery efficiency at least 85% and evaporative condensation units up to 92%
Low-temperature low-humidity indoor exhaust air is used as the cooling air of the evaporative condenser,which not only uses the sensible heat(temperature difference)of the indoor air exhaust heat,but uses the latent heat(humidity difference),ensuring  condensation effect is greatly better than that of the direct using outdoor air for cooling,preventing the energy loss due to air displacement and ventilation.Likewise,during heating of the unit, the high or low-temperature air exhausted from indoors can be used as the heat exchange souce at teh side of the evaporator.Compared with traditional central air conditioningsystems, it saves energy for about 50%.
f.Condensed water discharge system not needed(unique for evaporative condenser)
The condensed water coming from fresh air evaporation and to be treated can be directly introduced into the air exhaust condensation system of the unit a the cooling water,without the use of condensed water discharge system.Because lower condensed water temperature,not only the cooling capacity can e recovered,but the advanced film-type water cooling method can be utilized, enabling the cooling method can be utilized,enabling the cooling water to sufficiently wet the condensing fins,reinforce the heat exchange of condensing plate,and effectively overcome the scale phenomenon due to the water film on the fin liable to "dry point"
g.Independent ventilating system not needed
In the transitional seasons, fresh air can be used to bear indoor load,and only the supplying and exhaust fans are run to achieve automatioc air exchange,without starting the compressor,meanwhile it's no need of an independent air exchange system,greatly saving energy.
h.Advanced control,safe and reliable
All chinese LCD interface and microcomputer intelligent controller are adopted, have advanced control and completer functions;mechanical and electrical integrated design achieves unit start/shutdown program management,timing control,failure warning and fault self-diagnosis and other functions;the controller boasts optimal automatic control and power ful anti-interference capacity;multiple protections for e.g lack of phase ,phase sequence and unbalance,compressor overload,start delay, and abnormal air suction and discharge pressure,ans so on, ensuring running safety.Significantly lower initial investment.
2)Product model
 Heat Recovery Fresh Air Handling Unit
Model NumberHAX015HAX025HAX030HAX040HAX050HAX060HAX070HAX080HAX100HAX120HAX150HAX180HAX200HAX250HAX300HAX350
Cooling CapacityKW9121619232833364656698092112138167
Heating CapacityKW9.512.616.72024.33035394960738598120148180
Voltage220V~50HZ380V/3PH~50HZ
RefrigerantR22
Fresh Air SystemAir Flowm³/h150025003000400050006000700080001000012000150001800020000250003000035000
External Static PressurePa80100120150180180220240240250300350400420480500
Motor PowerKW0.30.550.750.751.11.52.22.23445.57.57.51115
Discharge Air SystemAir Flowm³/h150025003000400050006000700080001000012000150001800020000250003000035000
External Static PressurePa80100120150180220240250280300350400430450520550
Motor PowerKW0.30.550.750.751.11.52.22.23445.57.57.51115
Heat Exchange Efficiency>87%
CompressorType Rotor TypeFlexible Hermetic  Scroll Compressor
PowerKW1.72.252.533.754.53.75+2.23.75+2.23.75*24.5*23.75*34.5*33.75*49*29*2+3.759*3
Noise LeveldB(A)48505051525253535556586062656868
Weightkg31037039055059065078082089092098011801480155017801920
                   
Note:1.Nominal cooling condition: indoor discharge air:DB27ºC/WB19.5ºC,outdoor fresh air: DB34ºC/WB28ºC.           
           2.Nominal heating condition: indoor discharge air:DB21ºC/WB15ºC,outdoor fresh air: DB7ºC/WB6ºC.                                      
           3. Ambient  temperature conditions:-15ºC~43ºC        
          4. The specifications are subject to change without notice for improvement        
Model NumberHAXC010HAXC015HAXC020HAXC025HAXC030HAXC040HAXC050HAXC060HAXC080HAXC100HAXC120HAXC160HAXC200
Cooling CapacityKW8.811.515.52226.53444536678108155216
Heating CapacityKW9.312.1162327.535.546556981112160224
Voltage220V~50HZ380V/3PH~50HZ
RefrigerantR22/R407C
Fresh Air SystemAir Flowm³/h10001500200025003000400050006000800010000120001600020000
External Static PressurePa80100120120180180220240250300350420480
Motor PowerKW0.20.30.550.550.751.11.11.52.23445.5
Exhaust Air SystemAir Flowm³/h1800280035004500550070008500100001300016000200002800033000
External Static PressurePa100120150150180220240250300350400450550
Motor PowerKW0.550.751.11.11.52.22.23447.51115
Humidifying System (Optional)TypeWet Film Humidifier
Humidifyingkg/h355881010151520202525
SizemmDN16DN20DN25
Heat Exchange Efficiency>85%
CompressorType Rotor Type Hermetic  Scroll 
PowerKW1.72.252.53.754.53.75+2.253.75*24.5*23.75*34.5*39*29*39*4
Noise LeveldB(A)4850505.1525253535658606568
Weightkg300370390520570630780870920980115014501650
                
Note:1.Rated cooling condition: indoor discharge air:DB27ºC/WB19.5ºC,outdoor fresh air: DB34ºC/WB28ºC.        
            2.Rated heating condition: indoor discharge air:DB21ºC/WB15ºC,outdoor fresh air: DB7ºC/WB6ºC.                                   
            3. Work environment temperature:-15ºC~43ºC.     
           4.In winter, user may use an auxiliary heater and fresh air pre-heater (must be used in case of below -5ºC ambient temperature). Heating type: electric heating, hot water coil or steam coil heating.
           5.The humidifying system is optional.
3)Our company file

Head-Power Air-Conditioning Co., Ltd. is an professional company in air conditioning field,  located in Shiling Chenbian Industry Park, Nanhai District, Foshan,  Guangdong, China, the factory covers an area of 20,000 square meter. Within over ten years' experience in refrigerating and air conditioning, we can design, produce  and  sell almost all kinds of central air conditioning equipments, besides we also keep on developing new products.
 
Our factory has introduced many advanced equipments  and technologies from oversea and  built the most authoritative platform for product testing. Besides we have a close relationship with Central South University in Hunan Province and cooperation with some famous institutes. With so strong technical background, we ensure all the products meet the technical standards of the country.
 
We provide a wide range of products in Air Conditioning and Refrigerating, including Water & Geothermal Source Heat Pump Screw Chiller, Air Cooled Screw Water Chiller, Modular Water Cooled Chiller, Water Source Heat Pump, Air Cooled Water Chiller, Air Cooled Duct Split Unit, Rooftop Packaged Unis, Water Cooled Packaged Unit, Air Source Heat Pump Water Heater, Fan Coil Unit, Air Handling Unit,Heat Recovery Fresh Air Handling Unit, Precision Air Conditioner,Dehumidifier,etc.
Besides we can provide Integrated Solutions for Cooling, Heating and Hot Water. This system is specially designed for energy conservation. It is suitable for building that needs to cool in summer and heat in winter, which also needs hot water all the year round.
 
The products of our company have the characteristics of low noise, energy conservation and high efficiency. Head-Power follows ISO9001 international quality control system and ISO14001 international environment control system strictly, thus our product quality and services are ensured.


4)Company Culture:

Serve the society with technology, serve the customer with    heart, become a  first level air conditioning company in China.
Innovation, loyalty, responsibility, value.
Provide customer with high quality product and considerable service.

5)Our services:

1) Changing on material, color, shape, construction:Acceptable.
2) General inspection on fixing before packing
4) We can offer you premium quality , competitive price, prompt delivery and low minimum orders.
5) OEM,ODM service.

6)Project and client:

No

Project Name ( China)

Industry

Area

1

Zhongshan people hospital

Hospital

Zhongshan

2

Hankou Railway Station, Union Hospital, Wuhan Branch

Hospital

Wuhan

3

Wuhan City, Wuchang Railway Hospital

Hospital

Wuhan

4

Three townships Zhongshan People's Hospital

Hospital

Zhongshan

5

Zhujiang hospital of Guangzhou

Hospital

Guangzhou

6

Zhongshan Garden Hotel

Hotel   industry

Zhongshan

7

Western Sunshine Hotel, Zhongshan

Hotel   industry

Zhongshan

8

Shunde Golden Hotel

Hotel   industry

Foshan

9

East China Hotel in Guangzhou

Hotel   industry

Guangzhou

10

Nanyou Zhuhai hotel

Hotel   industry

Zhuhai

No

Company Name ( Overseas)

Product

Country

1

SB Global Energy

Air cooled ducted split

Holland

2

Bentos pharmaceutical products Ltd.

Clean air conditioners

Nigeria

3

SOGAMEF

Air cooled chiller

Gabon

4

SeaService shipping

Marine air conditioner

Russia

5

EURO STANDARD LIMITED

Fresh Air Handling Unit

New Zealand

6

Henrich trading center

Air cooled/water cooled air conditioner

Philippines

7

Marine Engineering Systems Pte.Ltd

AHU, chiller,etc

Singapore

8

Elektro Werner Heitzinger

Heat recovery air handling unit

Austria

9

Nyborg Marine Equipments AS

Marine Air Handling Units

Norway

10

Wilfred Limited

Heat recovery air handling unit

UK