China USB Temperature Humidity DC Voltage CO2 Carbon Dioxide Data Logger, Find details about China Data Logger, USB Data Logger from USB Temperature Humidity DC Voltage CO2 Carbon Dioxide Data Logger
Model | SRDL310 | SRDL311 | |
Temperature | Measurement range | -35~80°C (-31~176°F) | |
Accuracy(Typ.) | +/- 0.3°C (+/- 0.5°F) | ||
Resolution (Typ.) | 0.1°C (0.2°F) | ||
LCD | - | Yes | |
Memory Capacity | 64Kbytes (Total 32,000 readings) | ||
Sample Rate | User selectable from once every 10 seconds to once every 12 hours | ||
PC Software | DGraphTM software and USB driver required (Included on CD) | ||
Power Supply | User replaceable 1/2AA 3.6V Lithium Battery, 1200mAh | ||
Battery Life | Approx. 2 Years @ 1 Minute Sample Rate Approx. 4 Years @ 10 Minute Sample Rate Approx. 8 Years without any sample task NOTE: It also Depends on ambient temperatures and using of LEDs | ||
Case Material | ABS, TPU, PC | ||
Dimensions | 123mm * 37mm * 23mm (4.8" * 1.5" * 0.9") | ||
Weight | Approx. 90 grams(3.19 oz) |
Model | SRDL320 | SRDL322 | SRDL322P | |
Temperature | Measurement range | -35~80°C (-31~176°F) | ||
Accuracy(Typ.) | +/- 0.3°C (+/- 0.5°F) | |||
Resolution (Typ.) | 0.1°C (0.2°F) | |||
Relative Humidity | Measurement range | 0~100%RH | ||
Accuracy (Typ.) | +/- 3%RH | |||
Resolution (Typ.) | 0.1%RH | |||
LCD | - | Yes | Yes | |
Exporting Files Formats | EXCEL/ /TXT/JPG/PBM | PDF/EXCEL/ /TXT/JPG/PBM | ||
Memory Capacity | 64Kbytes (Total 32,000 readings for all channels) | |||
Sample Rate | User selectable from once every 10 seconds to once every 12 hours | |||
PC Software | DGraphTM software and USB driver required (Included on CD) | |||
Power Supply | User replaceable 1/2AA 3.6V Lithium Battery, 1200mAh | |||
Battery Life | Approx. 2 Years @ 1 Minute Sample Rate Approx. 4 Years @ 10 Minute Sample Rate Approx. 8 Years without any sample task NOTE: It also Depends on ambient temperatures and using of LEDs | |||
Case Material | ABS, TPU, PC | |||
Dimensions | 123mm * 37mm * 23mm (4.8" * 1.5" * 0.9") | |||
Weight | Approx. 90 grams(3.19 oz) |
Model | SRDL361 | |
Thermocouple Temperature | Measurement Range | K-type: -200 to 1370°C (-328 to 2498°F) J-type: -200 to 1190°C (-328 to 2174°F) T-type: -200 to 390°C (-328 to 734°F) |
Accuracy(Typ.) | +/-0.3%+/-1°C(+/-0.3%+/-2°F) | |
Resolution(Typ.) | 0.5°C(1°F) | |
Sensor Location | External | |
LCD | Yes | |
Memory Capacity | 64Kbytes (Total 32,000 readings) | |
Sample Rate | Every 1sec. to every 24hr. | |
PC Software | DGraph software and USB driver required (Included in CD) | |
Power Supply | User replaceable 1/2AA 3.6V lithium battery, 1200mAh | |
Battery Life | Approx. 1.5Years@ 1 Minute Sample Rate | |
Dimensions | 139mm*37mm*23mm(5.5''*1.5''*0.9'') | |
Case Material and Weight | ABS; Approx. 72grams(2.54 oz) |
Model | SRDL370 | SRDL371 | |
Air Pressure | Measurement range | 300 to 1100 hPa | |
Accuracy (Typ.) | +/- 1.5hPa | ||
Resolution (Typ.) | 0.1hPa | ||
Temperature | Measurement range | -35~80°C (-31~176°F) | |
Accuracy (Typ.) | +/- 0.3°C (+/- 0.5°F) | ||
Resolution (Typ.) | 0.1°C (0.2°F) | ||
Humidity | Measurement range | 0~100%RH | |
Accuracy (Typ.) | +/- 3%RH | ||
Resolution (Typ.) | 0.1%RH | ||
LCD | - | Yes | |
Sensor Location | Internal | ||
Memory Capacity | 64Kbytes (Total 31,998 readings) | ||
Sample Rate | Every 2sec. to every 24hr. | ||
PC Software | DGraphTM software and USB driver required (Included in CD) | ||
Power Supply | User replaceable 1/2AA 3.6V Lithium Battery, 1200mAh | ||
Battery Life | Approx. 2 Years @ 1 Minute Sample Rate Approx. 4 Years @ 10 Minute Sample Rate Approx. 8 Years without any sample task NOTE: It also Depends on ambient temperatures and using of LEDs | ||
Dimensions | 139mm * 37mm * 23mm (5.5" * 1.5" * 0.9") | ||
Case Material and Weight | ABS; Approx. 72 grams(2.54 oz) |
Model | SRDL330 | |
DC Voltage | Measurement range | 0 to 30V (0 to 3V, 5V, 10V, 12V and 24V etc. can be customized)★ |
Accuracy | +/- 1% | |
Resolution | 40mV (For 0 to 30V range) | |
Memory Capacity | 64Kbytes (Total 32,000 readings) | |
Sample Rate | User selectable from once every 10 seconds to once every 12 hours | |
PC Software | DGraphTM software and USB driver required (Included on CD) | |
Power Supply | User replaceable 1/2AA 3.6V Lithium Battery, 1200mAh | |
Battery Life | Approx. 3 Years @ 1 Minute Sample Rate | |
Case Material | ABS, TPU, PC | |
Operating Temperature Range | -35 to 80°C (-31 to 176°F) | |
Dimensions | 130mm * 37mm * 23mm (5.1" * 1.5" * 0.9")") | |
Weight | Approx. 80 grams(2.82 oz) |
Model | SRDL340 | |
Current Loop | Measurement range | 4 to 20mA (0 to 20mA can be customized)★ |
Accuracy | +/- 1% + 1 digit | |
Resolution | 40mV (For 0 to 30V range) | |
Memory Capacity | 64Kbytes (Total 32,000 readings) | |
Sample Rate | User selectable from once every 10 seconds to once every 12 hours | |
PC Software | DGraphTM software and USB driver required (Included on CD) | |
Power Supply | User replaceable 1/2AA 3.6V Lithium Battery, 1200mAh | |
Battery Life | Approx. 3 Years @ 1 Minute Sample Rate | |
Case Material | ABS, TPU, PC | |
Operating Temperature Range | -35 to 80°C (-31 to 176°F) | |
Dimensions | 130mm * 37mm * 23mm (5.1" * 1.5" * 0.9")") | |
Weight | Approx. 80 grams(2.82 oz) |
The power supply | 5VDC±10% |
Average power | 2.5W |
Detection of gas | Carbon dioxide, NDIR (Non-Dispersive Infra-Red) |
Measuring range | CO2: 0-9999ppm Temperature: -40~80ºC Humidity: 0~100%RH |
Accuracy | CO2: ±50ppm +5% Temperature: ±0.5ºC Humidity: ±3%RH |
Resolution | CO2: 1ppm Temperature: 0.1ºC Humidity: 0.1%RH |
Response Time | <30 Second |
Preheating Time | <5 Minutes |
Data Logger | a. Memory: 12332 readings b. Used as a u-disk c. Generate TXT logging file |
Charging | Input: AC100-240V Output: 5V,2A |
Operating Environment | 0~50ºC (32~122°F); 0~95%RH |
Store Condition | -20~50ºC, 0~90%RH, A standard atmospheric pressure |
Weigh/Size | 221g/126mm*84mm*36mm |