HID Tfc- 2012 -100g Home Water Filter System 100 Gpd Reverse Osmosis RO Membrane

China HID Tfc-2012-100g Home Water Filter System 100 Gpd Reverse Osmosis RO Membrane, Find details about China Filter Cartridge, RO Membrane from HID Tfc-2012-100g Home Water Filter System 100 Gpd Reverse Osmosis RO Membrane

Model NO.
TFC-2012-100G
Trademark
HID
Transport Package
in Carton & Pallets
Specification
100GPD
Origin
China
HS Code
8421999090
Model NO.
TFC-2012-100G
Trademark
HID
Transport Package
in Carton & Pallets
Specification
100GPD
Origin
China
HS Code
8421999090
Products Details:
HIDTM Residential Membrane ranks the best brand in China among the RO membrane industry. It has won the trust of thousands of families for feeding reliable purified water over 11 years. Each membrane is made of HID developed & pre-examined sheet and goes through stringent making processes as well as in-house quality inspection & testing before delivery.
HID Membrane has been certified by SGS & China Jiangsu Sanitation Bureau wrt drinking water membrane elements.
HID Tfc-2012-100g Home Water Filter System 100 Gpd Reverse Osmosis RO Membrane

Main Features:
★ HID high rejection quality sheet;
★ Long service life for reducing the cost;
★ High stabilized rejection with realized nominal flux;
★ Sanitary qualified elements;
★ Stringent in-house inspection & testing control.

HID Tfc-2012-100g Home Water Filter System 100 Gpd Reverse Osmosis RO Membrane

Membrane Performance Specifications:
Membrane Model No.Min. Salt Rejection (%)Stabilized Salt Rejection (%)Permeate Flow Rate (gpd)Test Temp.
(ºC)
Test PressureTest Water TDS
TFC-1812-5095975025 ºC65 psi500 ppm
TFC-1812-7595977525 ºC65 psi500 ppm
TFC-2012-100959710025 ºC65 psi500 ppm
TFC-2012-125959712525 ºC65 psi500 ppm
TFC-2012-150959715025 ºC65 psi500 ppm
TFC-2012-200959718025 ºC65 psi500 ppm

1. Permeate flow rate and salt rejection is based on testing conditions: 25C, pH 7.5, 20% recovery.
2. Stabilized salt rejection is generally achieved within 24-48 hours of continuous use, depending upon feedwater
characteristics and operating conditions.

Membrane Operating Limits:
RO Membrane Model No.Maximum Operating TemperatureMaximum Operating PressureFeed Water PH Range, continuous operationMaximum Feed Water TurbidityMaximum Feed Water SDIChlorine Tolerance
(ppm)
TFC-1812-5045 ºC200 psi4-111NTU5<0.1 ppm
TFC-1812-7545 ºC200 psi4-111NTU5<0.1 ppm
TFC-2012-10045 ºC200 psi4-111NTU5<0.1 ppm
TFC-2012-12545 ºC200 psi4-111NTU5<0.1 ppm
TFC-2012-15045 ºC200 psi4-111NTU5<0.1 ppm
TFC-2012-20045 ºC200 psi4-111NTU5<0.1 ppm

Membrane Dimension: HID Tfc-2012-100g Home Water Filter System 100 Gpd Reverse Osmosis RO Membrane
Model No.A ( inch / mm )B ( inch / mm )C ( inch / mm )D ( inch / mm )E ( inch / mm )
TFC-1812-5011.7 / 2980.78 / 200.66 / 16.81.73 / 4410.2 / 258
TFC-1812-7511.7 / 2980.78 / 200.66 / 16.81.77 / 4510.2 / 258
TFC-2012-10011.7 / 2980.78 / 200.66 / 16.81.85 / 4710.4 / 258
TFC-2012-12511.7 / 2980.78 / 200.66 / 16.81.85 / 4710.4 / 258
TFC-2012-15011.7 / 2980.78 / 200.66 / 16.81.9 / 48.510.4 / 258
TFC-2012-20011.7 / 2980.78 / 200.66 / 16.81.9 / 4810.4 / 258

Customization:

HID Tfc-2012-100g Home Water Filter System 100 Gpd Reverse Osmosis RO MembraneHID Tfc-2012-100g Home Water Filter System 100 Gpd Reverse Osmosis RO Membrane
About HID Membrane
HID, one of China leading ro membrane MANUFACTURERS, has been making ro membrane for over 11 years, and producing flat sheet for 5 years; so far our ro membranes have well be supplied to worldwide markets with good acceptance!
HID has developed full-auto rolling lines for residential/commercial/industrial RO membrane making, with annual output to 5.5 million pieces, and models from 50GPD/75GPD/100GPD/200GPD, to 300GPD/400GPD/600GPD, and up to 4040/8040!
With our latest auto production line of flat sheets (film) and testing facility, HID offers you the most reliable quality control and cost-efficiency!
HID Tfc-2012-100g Home Water Filter System 100 Gpd Reverse Osmosis RO MembraneHID Tfc-2012-100g Home Water Filter System 100 Gpd Reverse Osmosis RO MembraneHID Tfc-2012-100g Home Water Filter System 100 Gpd Reverse Osmosis RO MembraneHID Tfc-2012-100g Home Water Filter System 100 Gpd Reverse Osmosis RO MembraneOur Customers:
HID Tfc-2012-100g Home Water Filter System 100 Gpd Reverse Osmosis RO Membrane

HID Tfc-2012-100g Home Water Filter System 100 Gpd Reverse Osmosis RO Membrane


FAQ:

Q: Are you a trading company or a manufacturer?
A: We are one of China leading RO membrane manufacturers since 2008, with our OWN auto rolling line and OWN RO flat sheet making line!

Q: Where is your factory? How can I visit?
A: We located in Zhenjiang city of Jiangsu Province, which is west of Shanghai, 1.5 hours by express bullet train available every 30 minutes.

Q: Can we OEM from your factory?
A: Yes. Normally, we export under our brand name HID. If you have any request, we also provide OEM, ODM service.

Q: Can I get some samples? Can I place small order before bulk purchase?
A: We're glad to provide free sample, trial order welcome for first time, please kindly contact us.

Q: How can I place order? How can I pay you?
A: You can contact us by email about your order details, or place order on line. After you confirm our PI, we will request you to pay. T/T (Citibank) and Paypal, Western Union are the most usual ways we are using.

Q: How long is your delivery time?
A: Generally it is 3-5 days if the goods are in stock. Or it is 7-15 days if goods are not in stock, it is according to quantity.