Laboratory Use Digital Automatic Potential Titrator for Acid Base Titration

China Laboratory Use Digital Automatic Potential Titrator for Acid Base Titration, Find details about China Oil Acid Tester, Oil Acid Analysis from Laboratory Use Digital Automatic Potential Titrator for Acid Base Titration

Model NO.
HZ-1913
Power Source
AC220V
Test Range
0.002 ~ 1mg KOH / G
Power
500W
Huminity
≤85% Rh
Power Supply
AC220V / 50Hz
Repeatability
≤0.005mg KOH / G
Measurment Error
≤ ± 0.005mg KOH / G
Measurement Error
≤ ± 0.005mg KOH / G
Standards
GB/T7599-87, GB/T264-83, GB/T28522-2002
Aftersales Service
Yes
Trademark
HuaZheng
Transport Package
Wooden Box with Foam Inside
Specification
CE/ISO/IEC
Origin
Hebei, China
HS Code
9031809090
Model NO.
HZ-1913
Power Source
AC220V
Test Range
0.002 ~ 1mg KOH / G
Power
500W
Huminity
≤85% Rh
Power Supply
AC220V / 50Hz
Repeatability
≤0.005mg KOH / G
Measurment Error
≤ ± 0.005mg KOH / G
Measurement Error
≤ ± 0.005mg KOH / G
Standards
GB/T7599-87, GB/T264-83, GB/T28522-2002
Aftersales Service
Yes
Trademark
HuaZheng
Transport Package
Wooden Box with Foam Inside
Specification
CE/ISO/IEC
Origin
Hebei, China
HS Code
9031809090
Laboratory Use Digital Automatic Potential Titrator for Acid Base Titration
 

Overview

  • The system is ideal for use in the food, pharmaceutical, agricultural, and petroleum industries
  • Automatically titrates to your endpoint with easy digital control and curve
  • Ensure the accuracy of your measurements with precise burettes and sensors
  • Everything you need in one meter for Pre-titration, Black titration, Pre-endpoint titration, Manual titration, Constant titration, etc or set titrating mode by customer
  • Titration method: Acid/acidity, Redox, Precipitation, Complexometry, Non-aqueous titrations
  • Use the auto titrator with any combination pH electrode to do pH measurement
  • Data is easily exported to a printer or PC via USB port & RS 232 port or be view, deleted in the meter. Store up to 200 data sets in the meter's memory for retrieval later
  • Meter meets GLP requirements
 
                 
Specification
 
Titration
Device
Volumetric
Titration Unit
Repeatability of titration analysis0.2%
Allowable error of titration capacity10ml Burette: ±0.025ml;
20ml Burette: ±0.035ml
Resolution of burette10ml Burette: 1/10000;
20ml Burette: 2/10000
Speed of infusion(55±10) s
( When the burette is full scale )
Measurement
Device
Potential
Titration
Range(-1800.0~1800.0) mV
(0.00~14.00) pH
Resolution0.1mV, 0.01pH
Basic errorpH: ±0.01pH    mV: ±0.03%FS
Stability(±0.3mV±1bit) /3h
Temp. CompensationRange(-5.0~105.0) ºC
Resolution0.1ºC
Basic error±0.3ºC
Power SupplyAC(220±22)V; (50±1) Hz
Dimension (mm)& Weight (kg)540*490*480; 13
Standard Configuration10mL Valve-burette,
213-01 Platinum electrode,
216-01 Silver electrode,
231-01 pH electrode,
232-01 Reference electrode,
217-01 Reference electrode,
T-818-B-6 ATC probe
pH buffer
Optional Accessories20mL Valve-Burette;  
Auxiliary titration unit
Anti-diffusion capillary 
Upper stirrer
ISE probe;
Printer
Company Information
HuaZheng Electric Manufacturing (Baoding) Co.,Ltd is the supplier of the State Grid in China.It means we are the supplier of the Chinese Government.And our products spread throughout the whole China.
What's more, our customers come from different countries like America, England, Bulgaria, Brazil, Chile, Malysia, Vietnam and so on.

Our main products are Insulation Oil Tester, Cable Fault Locator, Power Quality Analyzer, High Voltage Generator, High Voltage Capacitor, Testing Transformer and so on.
Laboratory Use Digital Automatic Potential Titrator for Acid Base Titration

Customer Visit

Fair Trade Oil Test Equipment Transformer Oil Acidity Test Kit
Exhibition

Fair Trade Oil Test Equipment Transformer Oil Acidity Test Kit
Similar Recommandation

Laboratory Use Digital Automatic Potential Titrator for Acid Base Titration