Reliability Temperature & Humidity Test Chamber for Airplanes or Helicopters

China Reliability Temperature & Humidity Test Chamber for Airplanes or Helicopters, Find details about China Humidity Test Chamber, Climatic Test Chamber from Reliability Temperature & Humidity Test Chamber for Airplanes or Helicopters

Model NO.
KMH-408L
Humidity Range
20-98%R.H.
Temp. Constancy
+/-0.5oc
Humidity Constancy
+/-2.5%R.H.
Equipment Power
7.5kw
Heat up Time
-40 Oc~+100 Oc Within 45mins
Pull Down Time
+20 Oc~-40 Oc Within 60mins
Power
AC380+/-10% 50Hz 3phase4wires+Groud Wires
Trademark
KOMEG
Transport Package
Strong Plywood Case, Meet International Standards
Specification
CE, SGS
Origin
Dongguan, China
HS Code
90321000
Model NO.
KMH-408L
Humidity Range
20-98%R.H.
Temp. Constancy
+/-0.5oc
Humidity Constancy
+/-2.5%R.H.
Equipment Power
7.5kw
Heat up Time
-40 Oc~+100 Oc Within 45mins
Pull Down Time
+20 Oc~-40 Oc Within 60mins
Power
AC380+/-10% 50Hz 3phase4wires+Groud Wires
Trademark
KOMEG
Transport Package
Strong Plywood Case, Meet International Standards
Specification
CE, SGS
Origin
Dongguan, China
HS Code
90321000

Reliability Temperature Humidity Test Chamber  for airplanes or helicopters

Application
Temperature and Humidity Test Chamber is able to provide rapid product temperature change rates and use varying levels of relative humidity to locate design problems prior to shipping your products, improving product quality and reliability.
Reliability Temperature & Humidity Test Chamber for Airplanes or Helicopters
The technical parameter is as the following:
Environmental Temperature and Humidity Chamber
Secifications ( at +20ºC room temp.  Or+25ºC water temp with empty load)
ModelKMH-R seriesKMH-L seriesKMH-S series
150R225R408R800R1000R150L225L408L800L1000L225S408S800S1000S
Temp. range -20ºC~150ºC -40 ºC~+150ºC -70ºC~+150ºC 
Interior sizelW(mm)600700700100010006007007001000100070070010001000
H(mm)600700750100010006007007501000100070075010001000
D(mm)460480800800100046048080080010004808008001000
Exterior sizeW(mm)880980980128012808809809801280128098098012801280
H(mm)17301890194021602160173018901940216021601890194021602160
D(mm)14001460174017501950140014601740175019501460174017501950
Power(KW)5.867.512.812.87.57.58.514.514.59.510.618.518.5
Weight(KG)240280400500580250300420530600330450550650
Humidity uniformity±3.0%R.H±5.0%R.H±3.0%R.H±5.0%R.H±3.0%R.H±5.0%R.H
Heat up time -20ºC~+100ºC,within 35 min -40ºC~+100ºC, within 45 min -70ºC~+100ºC,within 60 min
Pull down time +20ºC~-20ºC, within 45 min +20ºC~-40ºC , within 60 min +20ºC~-70ºC,within 80 min
Standard accessoriesSight window*1,  cable port(portΦ50mm)*1,   shelves*2,    chamber lamp*1,    power cable *2m
Safety device  (standard)No fuse breaker, over pressure\over heat and over current protection for compressor,
Over temp. protect, over load protect of blower, dry heat protection
Control SystemBalanced Temperature & Humidity Control System
Refrigeration systemAir Cooled (Water Cooled Type is option)
Hermetic compressor,Single stage refrigeration system,                          CFC-Free refrigerant(HFC-507/HFC-23)Hermetic compressor, Cascade Refrigeration ,             CFC free refrigerant                           (HFC-507/HFC-23)
ControllerPanel:7-inch LCD Touch panel,    Chinese or English display selectable
Operation model :Program or fix point running
Memory capacity :120programs,1200steps,
All repeat 999 cycles, part repeat 99 cycles
Humidity Range20~98%R.H
Temp. constancy±0.5ºC   
Humidity constancy±2.5%R.H
Temp. uniformity±2.0ºC
Interior materialStainless Steel Plate(SUS 304)
Exterior materialBaked Painting Steel Or Stainless steel(SUS304)
Insulation materialRigid polyurethane Foam and Glass Fiber Wool
Ambient Temp.+5ºC~+35ºC
Wiring method AC 380±10%50Hz ,3 phase 4 wires +Ground Wires
Note:
1. We reserve the right to change specifications without prior notice
2. Customized sizes and configurations available
Reliability Temperature & Humidity Test Chamber for Airplanes or Helicopters
Standard configurations:
Sight window X 1
Cable port (port Ø 50mm) X 1
Shelves X 2
Chamber lamp X 1
Power cable X 2m
No fuse breaker, over-pressure, over-heat and over-current for compressor, over-temperature, overloading of blower, dry heat-protection
Optional accessories:
Cable port: Ø 100mm is available
Shelves
RO-type water purifier: R-80/day
Provided to keep the humidifying heater and wet bulb wick free from scale
Inner glass door with operating port: A glass door can be provided behind the main door so that specimens can be observed
Two operating ports of 130mm diameter are used for handing specimens inside the chamber without opening the glass door
Dehumidifier: The rotation regenerating dehumidifier M-120 ensures precise control of low-humidity (5° C 5% RH) for electronics
Reliability Temperature & Humidity Test Chamber for Airplanes or HelicoptersReliability Temperature & Humidity Test Chamber for Airplanes or HelicoptersReliability Temperature & Humidity Test Chamber for Airplanes or HelicoptersReliability Temperature & Humidity Test Chamber for Airplanes or Helicopters