Model NO.
KMHW-17
Volume(M3)
16.8cbm
Exterior Dimensions(W*H*D)
5050*2350*2250mm
Heat up Time
+20oc~+80oc Within 60mins
Pull Down Time
+20 Oc~-55 Oc Within 120mins
Insulation Material
Glass Wool+Rigid Polyurethane
Refrigeration System
Semi-Hermetic Compressor(Imported)
Temperature Change
1 to 2°c/Min
Trademark
KOMEG
Transport Package
Strong Plywood Case
Specification
Standard and Customized
Origin
Guangdong, China
HS Code
90321000
Model NO.
KMHW-17
Volume(M3)
16.8cbm
Exterior Dimensions(W*H*D)
5050*2350*2250mm
Heat up Time
+20oc~+80oc Within 60mins
Pull Down Time
+20 Oc~-55 Oc Within 120mins
Insulation Material
Glass Wool+Rigid Polyurethane
Refrigeration System
Semi-Hermetic Compressor(Imported)
Temperature Change
1 to 2°c/Min
Trademark
KOMEG
Transport Package
Strong Plywood Case
Specification
Standard and Customized
Origin
Guangdong, China
HS Code
90321000

Constant Environmental Walk-In Chamber for Temperature and Climate Testing  

Walk-In Temperature and Climate Test Chambers

KOMEG Walk-In Chamber serves as a test site for large components, assemblies, and finished products. KOMEG manufactures both Panel Walk-In Chambers and Solid Walk-In Chambers and can be configured as a temperature chamber or a temperature humidity chamber.

A Panel Walk-In Chamber is made from lightweight insulated panels for fast and easy installation. Usually for electronics temperature aging, like recharger, PCBA, Battery, LCD, scanners, monitors, LED, biological equipment, etc. Outside banding helps prevent leaking and keeps moisture out of the Walk-In Chamber and workspace temperatures steady.

Solid Walk-In Chambers are custom built to accommodate almost any size. They feature welded walls creating an environmental room for applications requiring controlled temperature and humidity testing exceeding 85°C. Typically, for ease of installation, a Solid Walk-In Chamber works best in new construction buildings, areas with extremely large doors, or rooms where outside walls can be easily removed.
Constant Environmental Walk-in Chambers for Temperature and Climate Testing

Walk-In Chamber Types

Model NumberTemperature RangeHumidity RangeTemperature ChangeRecommended Use
Panel Walk-in-60°C to +85°C20% to 95%RH1 to 2°C/minTemperature Cycling Temp / Humidity Cycling / Storage Testing
Solid Walk-In-60°C to +150°C20% to 95%RH4 to 5°C/min, or fasterTemperature Cycling
Temp / Humidity Cycling
Extreme Temp / Humidity Testing
Altitude Testing
Steady State Walk-In-20°C to +50°C20% to 95%RHN/AConstant Temperature
Constant Temp / Humidity
Storage Testing

The technical parameter is as below:
Specification of Walk-In Chambers
ModelKMHW-16.8
Volume(m³)16.8CBM
Interior DimensionsW3900*H2100*D2050mm
Exterior DimensionsW5050*H2350*D2250mm
Safety Devices(standard)No fuse breaker, over pressure\over heat and over current protection for compressor,over-temperature protection, overload protection for the blower, dry heat protection
Standard accessoriesSight window*1,cable port(portΦ50mm)*1,chamber lamp*1, status indicator
Control System Balanced Temperature & Humidity Control System
Refrigeration systemWater Cooled
Semi-hermetic compressor, single-stage or cascade refrigeration system,
CFC free refrigerant(HFC-507 and HFC-23)
ControllerPanel7-inch LCD Touch panel, Chinese or English display selectable
Operation modelProgram or fixpoint running
Memory capacity120 programs,1200steps, all repeat 999 cycles, part repeat 99 cycles
AccuracyTemp.:0.1% of F.S±1 digit  Humidity:0.1% of F.S±1 digit
InputTemp.:pt-100, Humidity:pt-100 or ~5V DCV
Comm.port RS-232 or RS-485 (Software is an option)
Temp. rangeMaximum:80ºC,120ºC;Minimum:-60ºC,-50ºC,-40 ºC,-30ºC,-20 ºC,-10ºC,0ºC
Humidity Range10%,20%,30%~95%
Temp. constancy±0.5ºC
Humidity constancy±2.5%R.H
Temp. uniformity±2.0ºC
Humidity uniformity±5.0%R.H
Ambient Temp.+5ºC~+35ºC
Wiring methodAC 380±10%50Hz,3 phase 4 wires +Ground Wires
Heat uptime +20ºC~+80ºC, Within 60 min
Pull downtime +20ºC~-55ºC\-40ºC\-20ºC\-10ºC,Within 120 or 90 or 60  min
Interior materialStainless Steel Plate(SUS 304)
Exterior materialBaked Painting Steel Or Stainless steel(SUS304)
Insulation materialRigid polyurethane foam
Door size (mm)Single wing:W800*H1800;Double wing:W1600*H1800;
Note:1. We reserve the right to change specifications without prior notice   2.Customized sizes and configurations available
Specification for Walk-in Chamber
ModelKMHW-6
Volume(m³)6CBM
Interior DimensionsW3000*H2100*D2050mm
Exterior DimensionsW4160*H2350*D2250mm
Safety Devices(standard)No fuse breaker, overpressure, overheat and over current protection for compressor,over-temperature protection, overload protection for the blower, dry heat protection
Standard accessoriesSight window*1,cable port(portΦ50mm)*1,chamber lamp*1, status indicator
Control SystemBalanced Temperature & Humidity Control System
Refrigeration systemWater Cooled
Semi-hermetic compressor, single-stage or cascade refrigeration system,
CFC free refrigerant(HFC-507 and HFC-23)
ControllerPanel7-inch LCD Touch panel, Chinese or English display selectable
Operation modelProgram or fixpoint running
Memory capacity120 programs,1200steps, all repeat 999 cycles, part repeat 99 cycles
AccuracyTemp.:0.1% of F.S±1 digit Humidity:0.1% of F.S±1 digit
InputTemp.:pt-100, Humidity:pt-100 or ~5V DCV
Comm.portRS-232 or RS-485 (Software is an option)
Temp. rangeMaximum:80 ºC,120 ºC;Minimum:-60 ºC,-50 ºC,-40 ºC,-30 ºC,-20 ºC,-10 ºC,0 ºC
Humidity Range10%,20%,30%~95%
Temp. constancy±0.5 ºC
Humidity constancy±2.5%R.H
Temp. uniformity±2.0 ºC
Humidity uniformity±5.0%R.H
Ambient Temp.+5 ºC~+35 ºC
Wiring methodAC 380±10% 50Hz,3 phase 4 wires +Ground Wires
Heat uptime+20 ºC~+80 ºC, Within 60 min
Pull downtime+20 ºC~-55 ºC, -40 ºC,-20 ºC,-10 ºC,Within 120 or 90 or 60 min
Interior materialStainless Steel Plate(SUS 304)
Exterior materialBaked Painting Steel Or Stainless steel(SUS304)
Insulation materialRigid polyurethane foam
Door size (mm)Single wing:W800*H1800; Double wing:W1600*H1800;
Note:
1. We reserve the right to change specifications without prior notice
2.Customized sizes and configurations available

Constant Environmental Walk-in Chambers for Temperature and Climate Testing
Constant Environmental Walk-in Chambers for Temperature and Climate TestingConstant Environmental Walk-in Chambers for Temperature and Climate TestingConstant Environmental Walk-in Chambers for Temperature and Climate TestingConstant Environmental Walk-in Chambers for Temperature and Climate TestingConstant Environmental Walk-in Chambers for Temperature and Climate Testing
After-sale service

If you face any problems in the future during the testing process we promise we will give you a reply within 48 hours and the solution provide within 3 working days. We can offer operation video and English operation muanual. We can provide video-conference. If customers require on-site service, the transport and travel expense shall be borne by the customer.