Onsite Test Current Transformer Analyzer/ Potential Transformer Analysis Instrument (GDHG-201P)

China Onsite Test Current Transformer Analyzer/Potential Transformer Analysis Instrument (GDHG-201P), Find details about China Current Transformer Analyzer, Potential Transformer Analyzer from Onsite Test Current Transformer Analyzer/Potential Transformer Analysis Instrument (GDHG-201P)

Model NO.
GDHG-201P
Insulating Medium
Common Insulating Materials
Output
0~180Vrms, 12Arms, 36A(Peak Value)
Voltage Measuring Precision
±0.1%
CT Turns Ratio Test
1~40000, accuracy ±0.05%
PT Turns Ratio Test
1~40000, accuracy ±0.1%
Phase Test
±2 min, accuracy 0.5 min
Secondary winding resistance Test
0~300Ω, 0.2%±2mΩ
AC burden Test
0~1000VA, accuracy 0.2%±0.02VA
Trademark
HV Hipot
Transport Package
Carton or Wooden Case
Specification
ISO, SGS
Origin
Wuhan China
HS Code
9030849000
Model NO.
GDHG-201P
Insulating Medium
Common Insulating Materials
Output
0~180Vrms, 12Arms, 36A(Peak Value)
Voltage Measuring Precision
±0.1%
CT Turns Ratio Test
1~40000, accuracy ±0.05%
PT Turns Ratio Test
1~40000, accuracy ±0.1%
Phase Test
±2 min, accuracy 0.5 min
Secondary winding resistance Test
0~300Ω, 0.2%±2mΩ
AC burden Test
0~1000VA, accuracy 0.2%±0.02VA
Trademark
HV Hipot
Transport Package
Carton or Wooden Case
Specification
ISO, SGS
Origin
Wuhan China
HS Code
9030849000
Onsite Test Current Transformer Analyzer/Potential Transformer Analysis Instrument (GDHG-201P)

GDHG-201P CT/PT Analyzer

General introduction

GDHG-201P CT/PT Analyzer is designed for analyzing current transformers and voltage transformers of protection or measurement use, adopts high-performance DSP and FPGA, advanced manufacturing process to ensure stable and reliable product performance, complete functions, high degree of automation, high test efficiency, which is suitable for laboratory and on-site test.


Features
  • Full function and can satisfy all kinds of CT (protection CT, measuring CT, TP) test requirements, such as excitation characteristic test, turn ratio, polarity, secondary winding resistance, secondary burden, ratio error, angular difference and etc. Also can used to test excitation characteristic, turn ratio, polarity, secondary winding resistance, ratio error, angular difference and etc of all kinds of PT.
  • Field verification of CT does not require standard current transformers, current injector, load bank, voltage regulating controller and large current cables. Very simple test wiring and operation are used to realize the current transformer verification, which greatly reduces the work intensity and improves the work efficiency, and facilitates the field verification of transformers.
  • Accurately measure the ratio error and angular difference, the maximum allowable error of the ratio error is ±0.05%, and the maximum allowable error of the angular difference is ±2min. It can measure the 0.2S level current transformer, and the ratio measurement range is 1~40000.
  • Based on the advanced frequency conversion method to test CT/PT voltage-current characteristic curve and 10% error curve, the maximum AC voltage of 180V and AC current of 12Arms (36Apeak) can be output, but it can deal with the CT test of knee point up to 60KV.
  • Auto test CT/PT parameters such as knee point voltage/current, 5% and 10% error curve, accuracy limit factor (ALF), safety factor (FS), secondary time constants (Ts), magnetic remanence coefficient (Kr), saturated and unsaturated inductance.
  • The test meets various types of transformer standards such as GB1208 (IEC60044-1), GB16847 (IEC60044-6), and GB1207, and tests standards are automatically selected according to the type and level of the transformer.
  • The test is simple and convenient. CT DC resistance, excitation, ratio and polarity can be completed by one key. Besides burden test, all other tests of CT adopt the same wiring mode.
  • 5.7-inch graphic transflective LCD, clearly visible in the sun.
  • Operated with a rotating optical mouse, the operation is simple, fast and convenient, and easy to master.
  • Built-in printer, automatically prints the generated test report.
  • The test results can be exported by U disk, and the program can be upgraded with U disk, which is convenient and quick.
  • Save 1000 groups data and it is not lost after power down.
  • It is equipped with background analysis software to facilitate the storage, conversion and analysis of test reports, and can be used for comparison, judgment and evaluation of test data.
  • Easy to carry, device weight <10 kg.


Specification

Main parameters
ModelGDHG-201P
ApplicationCT, PT
Output 0~180Vrms, 12Arms,36A(Peak Value)
Voltage Measuring Precision±0.1%
CT Turns Ratio TestRange1~40000
Precision±0.05%
PT Turns Ratio TestRange1~40000
Precision±0.1%
Phase TestRange±2 min
Precision0.5 min
Secondary winding resistance TestRange0~300Ω
Precision0.2%±2mΩ
AC burden TestRange0~1000VA
Precision0.2%±0.02VA
Input voltageAC220V±10%, 50Hz
Working environmentTemperature:-10ºC~50ºC, Humidity: ≤90%
Dimension & Weight365*290*153mm,10kg


Accessories
 
Host1 piece
Power cord 1 piece
Red test cable1 piece
Yellow test cable1 piece
Green test cable 1 piece
Ground cable 1 piece
Alligator clip (Jaw 12mm)4 pieces
Alligator clip (Jaw 20mm)2 pieces
Inserting piece4 pieces
Print paper4 rolls
U disk1 piece
Fuse 10A5 pieces
Special screwdriver for fuse1 piece
User's guide1 copy
Warranty period1 copy
Packing list1 copy
Factory test report1 copy